Data Centers Could Recycle Waste Heat for Cooling Using Adsorption Heat Pumps

August 26, 2026
in Climate
Reading Time: 5 mins read
0
Data Centers Could Recycle Waste Heat for Cooling Using Adsorption Heat Pumps

Data Centers Could Recycle Waste Heat for Cooling Using Adsorption Heat Pumps

65
SHARES
587
VIEWS
Share on FacebookShare on Twitter
ADVERTISEMENT

The world’s data centers are becoming giant furnaces—and researchers now propose using that heat to make more cooling. A study led by engineers Jinkyun Cho and Joo Hyun Moon describes a “cooling-from-cooling” system that captures heat from liquid-immersed computer hardware and feeds it into an adsorption heat pump. The device then produces chilled water for cooling other equipment, creating a thermal recycling loop designed to reduce dependence on electrically driven cooling machinery. In a prototype-scale design, 50 kilowatts of heat recovered from a 200-kilowatt immersion-cooling system would generate approximately 20 kilowatts of additional cooling. The concept could offer data-center operators a way to expand computing capacity while making use of heat that would otherwise be rejected to the atmosphere.

The proposal arrives as artificial intelligence, cloud computing and connected devices drive an extraordinary expansion in computing infrastructure. Data centers consumed an estimated 240–340 terawatt-hours of electricity in 2022, equivalent to roughly 1–1.3 percent of global electricity use, according to the International Energy Agency. That demand is expected to more than double by 2030. Although electricity powers the processors, memory and networking equipment, nearly all of the energy consumed by information technology ultimately becomes heat. Keeping that heat away from sensitive electronics can account for about 30–40 percent of a facility’s energy use under some operating conditions. Conventional systems move heat into chilled water or exhaust air, then reject it through cooling towers or dry coolers. Much of the thermal energy is therefore lost despite being continuously available.

The challenge is not simply the amount of heat, but its temperature and thermodynamic quality. Traditional air-cooled servers generally release heat at only about 35–45 °C, while condenser-water loops may return at around 37 °C. That is abundant energy, but it is “low grade”: its temperature is too close to the surrounding environment to drive many useful heat engines or industrial processes. Warm-water liquid cooling can raise the outlet temperature to roughly 50–65 °C, and two-phase systems may reach 70–90 °C, but these more advanced technologies introduce engineering concerns involving leakage, vapor distribution, reliability and long-term stability. The researchers identify an intermediate range of approximately 45–60 °C as the most practical for their approach. It is hot enough to regenerate an adsorption cycle, yet compatible with liquid cooling systems that can keep high-power processors within safe operating limits.

An adsorption heat pump does not use a mechanically compressed refrigerant in the way a conventional electric chiller does. Instead, it relies on the ability of a porous solid to attract and release a refrigerant, in this case water vapor, as its temperature changes. The proposed machine contains two beds of adsorbent material, a condenser and an evaporator. While one bed is heated, or regenerated, hot water drives water vapor out of the material. That vapor condenses, and the liquid refrigerant then evaporates at low pressure, absorbing heat from a chilled-water loop. The evaporator thereby produces cooling. At the same time, the second bed adsorbs vapor and releases heat to cooling water. The two beds periodically switch roles, allowing the cycle to continue. Because the regeneration energy comes from data-center waste heat, the system can produce cooling without adding a compressor or requiring an electrically powered heat-up stage.

To test whether the cycle could function with data-center heat, the researchers modeled two adsorbent–water pairs: silica gel–water and MIL-101(Cr)–water. Their calculations used a Linear Driving Force model, a standard approximation for transient adsorption and desorption. In that model, the rate at which refrigerant is taken up or released depends on the difference between the material’s instantaneous uptake and its equilibrium uptake. The model also included the heat released during adsorption, the heat required for desorption, the thermal masses of the bed and adsorbent, and the temperatures and flow rates of the working fluids. The coupled equations were solved with adaptive numerical time stepping because the cycle involves rapidly changing, nonlinear interactions between heat and mass transfer. A cycle time of about 200 seconds produced stable behavior in the simulation.

The modeled system used hot water entering the adsorption beds at 53 °C and cooling water entering at 32 °C. Under these conditions, the silica-gel system delivered a coefficient of performance, or COP, of about 0.77 in the reported calculation. COP is the ratio of cooling delivered to thermal energy supplied; it is not directly comparable to the COP of an electric compressor because the energy input is primarily heat rather than electricity. The model showed that raising the regeneration temperature could actually reduce performance: silica gel’s COP fell to 0.27 at 63 °C and 0.17 at 73 °C. The researchers attribute this decline to greater refrigerant uptake and larger enthalpy flows during short cycles, increasing the thermal input required for each unit of cooling. The MIL-101(Cr)–water pair produced COP values of approximately 0.25–0.40 and showed stronger adsorption potential at lower cold-bed temperatures. These results suggest that choosing the adsorbent and operating temperature together will be crucial.

The proposed engineering configuration combines six immersion tanks, two coolant distribution units, an adsorption heat pump and a rear-door heat exchanger. The immersion system is designed for a 200-kilowatt information-technology load, with each tank handling about 34 kilowatts. One 50-kilowatt section of the cooling loop sends hot coolant to the adsorption heat pump, while a separate 150-kilowatt section continues to the cooling tower. The recovered heat enters the heat pump at approximately 53 °C and leaves at about 48 °C. The resulting 20-kilowatt chilled-water output leaves the evaporator at 20 °C and is sent to a rear-door heat exchanger serving an additional 18-kilowatt air-cooled load. Pumps, fans and heat exchangers were sized with allowances for flow resistance and piping losses. The design therefore does not claim that all data-center heat can be converted into cooling; rather, it diverts a carefully selected fraction into a thermal cycle while the remaining heat follows the conventional rejection path.

The energy analysis produced a more complicated result than a simple claim of universal electricity savings. Compared with immersion cooling alone, the internal-reuse configuration required additional pumps, a heat exchanger and a rear-door fan. At full design load, the baseline system had a mechanical load component of 0.051 and a cooling-focused power usage effectiveness, or PUE, of 1.051. With heat recovery used internally, those values increased to 0.065 and 1.065 because the extra equipment consumed mechanical energy. However, the same configuration enabled the facility to cool an additional 18-kilowatt air-cooled information-technology load, raising the total modeled IT load from 200 to 218 kilowatts without adding compressor power. In a second scenario, where recovered heat was credited against an external cooling demand, the calculated mechanical load component fell to 0.031 and PUEcooling to 1.031. The distinction matters: recycling heat within the facility can increase cooling capacity even when it does not reduce the cooling system’s own electricity use, while exporting the recovered thermal benefit can improve the accounting efficiency more directly.

The study is a theoretical and prototype-scale demonstration rather than proof of commercial performance. Its calculations assume continuous operation at full rated load for 8,760 hours per year, whereas real computing demand fluctuates and cooling towers perform differently across climates and seasons. Adsorption machines also tend to have lower COPs and slower dynamic responses than mechanical chillers, and maintaining a stable 200-second switching cycle under changing server loads may be difficult. The researchers say a pilot system is being developed for experimental validation, including tests of operating stability, thermal matching and real-world energy consumption. If those tests confirm the model, the approach could be especially valuable in high-density computing facilities where cooling capacity—not processor availability—is becoming the main limit on expansion. Rather than treating waste heat as an unwanted by-product, the system turns it into a second chance to remove heat, closing a loop that could help data centers handle the escalating thermal burden of artificial intelligence.

Subject of Research: Recycling liquid-cooled data-center waste heat to produce additional cooling through an adsorption heat pump

Article Title: Cooling-from-cooling: Data-center waste-heat recovery using an adsorption heat pump

Article References: Cho, J. and Moon, J.H., original research source supplied without a publication URL

Image Credits: AI Generated

DOI: Not provided

Keywords: data-center cooling, waste-heat recovery, adsorption heat pump, immersion cooling, liquid cooling, artificial intelligence infrastructure, energy efficiency, power usage effectiveness

Tags: adsorption heat pump technology for coolingartificial intelligence impact on data center energy useData center waste heat recyclingenergy-efficient data center designenvironmentally friendly data center cooling methodsglobal energy consumption of data centersheat reuse in cloud computing infrastructureheat-to-cooling conversion systemshigh-capacity heat recovery systemsreducing data center carbon footprintsustainable data center cooling solutionsthermal energy recovery in data centers
Share26Tweet16
Previous Post

New method prequalifies offshore wind turbines under normal Moroccan Atlantic metocean conditions

Next Post

Study identifies global genetic factors influencing fetal hemoglobin in sickle cell disease

Related Posts

Rethinking Wetlands: Balancing Biodiversity, Methane Reduction, and 2030 Climate Targets
Climate

Rethinking Wetlands: Balancing Biodiversity, Methane Reduction, and 2030 Climate Targets

August 26, 2026
Optimizing Recycled Polypropylene Performance by Balancing Sorting and Modification
Climate

Optimizing Recycled Polypropylene Performance by Balancing Sorting and Modification

August 26, 2026
New Framework Helps Track Chesapeake Bay Resilience and Adaptation
Climate

New Framework Helps Track Chesapeake Bay Resilience and Adaptation

August 26, 2026
What Drives Farmers to Join the U.S. Conservation Reserve Program?
Climate

What Drives Farmers to Join the U.S. Conservation Reserve Program?

August 26, 2026
How Soil Amendments Affect Antibiotic Forms and Bioavailability in Saline-Alkali Soils
Climate

How Soil Amendments Affect Antibiotic Forms and Bioavailability in Saline-Alkali Soils

August 26, 2026
Fuzzy Decision Tool Identifies Bioethanol Pathways Supporting Sustainable Development Goals
Climate

Fuzzy Decision Tool Identifies Bioethanol Pathways Supporting Sustainable Development Goals

August 26, 2026
Next Post
Study identifies global genetic factors influencing fetal hemoglobin in sickle cell disease

Study identifies global genetic factors influencing fetal hemoglobin in sickle cell disease

  • Mothers who receive childcare support from maternal grandparents show more

    Mothers who receive childcare support from maternal grandparents show more parental warmth, finds NTU Singapore study

    27656 shares
    Share 11059 Tweet 6912
  • University of Seville Breaks 120-Year-Old Mystery, Revises a Key Einstein Concept

    1061 shares
    Share 424 Tweet 265
  • Bee body mass, pathogens and local climate influence heat tolerance

    682 shares
    Share 273 Tweet 171
  • Researchers record first-ever images and data of a shark experiencing a boat strike

    546 shares
    Share 218 Tweet 137
  • Groundbreaking Clinical Trial Reveals Lubiprostone Enhances Kidney Function

    531 shares
    Share 212 Tweet 133
Science

Embark on a thrilling journey of discovery with Scienmag.com—your ultimate source for cutting-edge breakthroughs. Immerse yourself in a world where curiosity knows no limits and tomorrow’s possibilities become today’s reality!

RECENT NEWS

  • MEYELens Makes Affordable 3D-Printed Eyewear for Pupil and Gaze Tracking
  • Scientists Advance Precision Cancer Immunotherapy
  • Three New Chinese Neritidae Mitochondrial Genomes Clarify Their Evolutionary Relationships
  • Scientists uncover how natural products may combat chronic obstructive pulmonary disease

Categories

  • Agriculture
  • Anthropology
  • Archaeology
  • Athmospheric
  • Biology
  • Biotechnology
  • Blog
  • Bussines
  • Cancer
  • Chemistry
  • Climate
  • Earth Science
  • Editorial Policy
  • Marine
  • Mathematics
  • Medicine
  • Pediatry
  • Policy
  • Psychology & Psychiatry
  • Science Education
  • Social Science
  • Space
  • Technology and Engineering

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 5,150 other subscribers

© 2025 Scienmag - Science Magazine

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • HOME
  • SCIENCE NEWS
  • CONTACT US

© 2025 Scienmag - Science Magazine

Discover more from Science

Subscribe now to keep reading and get access to the full archive.

Continue reading