In clinical pharmacy practice, the choice of tablet crushing method and crushing time directly affects the solid-state properties, dissolution behavior, and packaging loss of acetaminophen tablets, according to a study published in the Journal of Pharmaceutical Health Care and Sciences. The study compared three crushing methods available to pharmacists—a mortar and pestle, a tablet crusher, and an oscillatory ball mill—using the same acetaminophen tablets. Their findings demonstrate that crushing is not a neutral physical step, as different crushing tools produce distinct structural changes, dissolution rates, and measurable powder loss during automated packaging.
In clinical practice, tablets are often crushed and administered to patients with dysphagia or children. Crushing is typically performed using a mortar and pestle, a tablet crusher, or other methods of administration. Clinical tablet crushing may alter the physicochemical properties of drugs; however, the effects of crushing methods on pharmaceutical quality remain unclear.
To investigate these questions, the researchers compared the three crushing modalities using the same acetaminophen tablets under controlled conditions. The researchers evaluated the physicochemical properties of the crushed samples, including particle size distribution, SEM, PXRD, and DSC. The evaluations also included FTIR, dissolution, flowability, and dispensability.
The analytical measurements revealed that all three crushing methods reduced the baseline crystallinity of the acetaminophen tablets, but they did so to differing degrees. The oscillatory ball mill generated the most pronounced solid-state alterations among the tested techniques, substantially modifying the crystalline integrity of the drug. In contrast, the tablet crusher produced relatively fine particles and showed the most rapid initial dissolution under the experimental conditions.
The choice of crushing equipment also produced notable consequences for the dispensability of the powders during automated dividing and packaging, which determines the dosage accuracy received by patients. When the researchers tested the powders in an automated V-shaped powder dispensing machine, weight loss remained low across all crushing methods and grinding durations, ranging between 1.0 percent and 3.3 percent.
In contrast, automated packaging performance shifted markedly when the researchers evaluated the crushed samples using a rotary disk-type dispensing machine. Under this packaging format, powder weight loss increased substantially with longer processing times, reaching 8.5 percent after five minutes of grinding in an oscillatory ball mill and climbing to 10.0 percent after five minutes with the tablet crusher.
Based on these findings, the study authors concluded that no single crushing method is superior in all pharmaceutical aspects, as pulverization mechanics and processing times exert competing effects on drug dissolution and packaging performance. The researchers noted that preparation techniques and crushing times must be chosen in coordination with the specific type of automated packaging equipment in use. Furthermore, the authors concluded that prolonged grinding with the oscillatory ball mill should be avoided.
Subject of Research: Effects of tablet crushing methods on acetaminophen properties and automated packaging dispensability
Article Title: Effects of tablet crushing methods on solid-state properties, dissolution behavior, and dispensability of acetaminophen tablets
Article References: Kawano, Y., Tsuchida, T., Rong, N., Hirose, K., Natori, N., Maida, N., Goto, S., & Hanawa, T. (2026). Effects of tablet crushing methods on solid-state properties, dissolution behavior, and dispensability of acetaminophen tablets. Journal of Pharmaceutical Health Care and Sciences. https://doi.org/10.1186/s40780-026-00641-8
Image Credits: AI Generated
DOI: 10.1186/s40780-026-00641-8
Keywords: acetaminophen, tablet crushing, solid-state properties, crystallinity, dissolution behavior, dispensability, powder dispensing machine, oscillatory ball mill, mortar and pestle, tablet crusher, dysphagia, pediatric drug administration, powder X-ray diffraction, differential scanning calorimetry, Fourier transform infrared spectroscopy, scanning electron microscopy, particle size distribution, rotary disk packaging machine
Cite Scienmag News
Ophelia Keating. (November 16, 2026). Tablet Crushing Methods Alter Acetaminophen Crystallinity, Dissolution, and Packaging Dose Accuracy. Scienmag. https://scienmag.com/tablet-crushing-methods-alter-acetaminophen-crystallinity-dissolution-and-packaging-dose-accuracy/
Ophelia Keating. "Tablet Crushing Methods Alter Acetaminophen Crystallinity, Dissolution, and Packaging Dose Accuracy." Scienmag, 16 November 2026, https://scienmag.com/tablet-crushing-methods-alter-acetaminophen-crystallinity-dissolution-and-packaging-dose-accuracy/. Accessed 16 November 2026.
Ophelia Keating. "Tablet Crushing Methods Alter Acetaminophen Crystallinity, Dissolution, and Packaging Dose Accuracy." Scienmag. November 16, 2026. https://scienmag.com/tablet-crushing-methods-alter-acetaminophen-crystallinity-dissolution-and-packaging-dose-accuracy/








