Finite element simulations of soil-structure interaction across multi-story reinforced concrete structures reveal that soil amplification factors diminish substantially as earthquake ground motion intensity grows. Investigating structural models founded on diverse soils, the analysis demonstrates that elevating peak absolute acceleration from 0.075 g to 0.30 g reduces amplification factors by 5 percent to 20 percent across site classes B, C, and D. Concurrently, shifting site conditions from dense soil class B to softer classes C and D increases amplification factors by 11 percent and 20 percent under comparable acceleration levels. These computational outcomes confirm that soil flexibility governs wave transmission and structural demands during earthquakes, exposing critical limitations in building codes that assume constant amplification factors regardless of ground motion intensity.
The dynamic response of reinforced concrete structures during earthquake excitations depends strongly on interaction between the superstructure, foundation, and supporting soil bed. In traditional structural assessments, buildings are frequently modeled with fixed-base assumptions that neglect the compliance of underlying ground. However, numerical evaluations confirm that flexible foundation soils alter structural behavior by lengthening the fundamental period and modifying the effective damping ratio compared with rigid-base conditions. When seismic shear waves propagate upward through deformable stratigraphies, soil-structure interaction shifts natural frequencies and modifies acceleration amplification across subterranean soil layers. Structures erected on softer soils exhibit markedly larger lateral displacements accompanied by reduced base shear demands relative to buildings on dense soils, reflecting substantial stress redistributions generated when foundation soils yield.
To capture these physical behaviors, computational engineers contrast substructure methodologies with direct analysis approaches. While substructure techniques divide the soil-foundation-structure continuum into isolated analytical components and cannot simultaneously track non-linear inelastic behavior in both soil and structural materials, the direct analysis approach models the superstructure, foundations, and contiguous 3D continuum soil block in a unified framework. Extending the numerical soil mesh around and beneath the building allows direct analysis to accurately capture constitutive soil behaviors and site properties. Ground motions are imparted at peripheral boundaries of the soil domain, propagating seismic waves through soil elements to excite the structure. Because foundation dimensions, structural properties, and soil moduli fundamentally govern seismic response, three-dimensional continuum modeling provides the requisite realism to evaluate inelastic material properties that substructure approximations omit.
The investigation builds on insights established in previous analytical literature regarding soil-structure interaction, amplification factors, dynamic soil behavior, and response modification factors. Earlier research by Ismail, Kaddah, and Raphael in 2020 evaluated midrise concrete frame structures of 5 to 15 stories resting on raft foundations in silty sand soils using ABAQUS. Their finite element analysis demonstrated that column dimensions strongly influence flexible structure behavior, whereas varying raft thickness produces only minor differences in seismic response despite base shear growing with raft size. In parallel, 2017 research by Zafarkhah and Dehkordi examined variable soil types and structure heights, modeling sand yield surfaces with Drucker-Prager plasticity and clay with Von Mises criteria. They observed that soil-structure interaction was more pronounced in looser sands and medium clays, intensifying as low- and midrise buildings grew taller but wearing off in high-rise structures.
To ensure the reliability of their numerical models, the authors verified their nonlinear finite element modeling procedures against experimental data using ABAQUS 6.14. One primary validation benchmark utilized shaking table tests conducted by Behzad Fatahi in 2012, which evaluated a ten-story moment-resisting frame structure resting on soft soils under three earthquake records. Fatahi tested two physical cases: a fixed-base structure excluding soil interaction and a structural model supported by an end-bearing pile foundation embedded in soft soil. The numerical model reproduced these shaking table tests while holding damping ratios and modulus reduction constant during analysis. Comparing analytical displacement outputs with experimental observations using error percentage calculations showed close agreement between analytical and experimental records, confirming that the developed ABAQUS models can reliably simulate dynamic structural responses resting on soft soils.
A second experimental validation examined tests reported by Korkmaz in 2010, which investigated a one-bay, two-story reinforced concrete specimen without infill walls subjected to reversed cyclic loading. That study assessed structural performance related to Turkish earthquake code provisions for a specific strengthening scheme. Lateral loads were applied cyclically at story levels in forward and backward directions to simulate seismic actions, while columns were subjected to constant axial loads. In the numerical simulation, ABAQUS captured crack propagation and plastic hinge formation resulting from tension failure. Comparing analytical pushover results against experimental observations revealed strong agreement across lateral displacements and shear forces. With errors demonstrating consistency across shaking table time-history tests and cyclic pushover analyses, the authors concluded that the finite element models reliably simulate real-life responses of multi-story concrete structures.
Accurate numerical representation of reinforced concrete members requires modeling non-linear behavior arising from concrete compressive crushing, concrete tensile cracking, and reinforcement yielding. The authors represented concrete under combined compression, tension, and cyclic loading using the Concrete Damage Plasticity model, which captures stiffness degradation, cracking, and crushing under multiaxial stress states. Compressive and tensile damages are governed by damage variables, dc and dt, ranging from zero for undamaged material to one for complete loss of strength as functions of plastic strains, temperature, and field variables. Steel reinforcement was modeled as an isotropic multi-linear elasto-plastic material using two-node truss elements (T3D2). The rebar elements were incorporated into concrete solid elements using the embedded element technique with a fractional exterior tolerance of 0.05, properly accounting for dowel action and bond slip.
For the geotechnical domain, the elastic perfectly plastic model incorporating the Mohr-Coulomb failure criterion was selected to simulate soil nonlinearity, plastic yielding, and shear failure mechanisms. Under Mohr-Coulomb theory, material failure depends strictly on the major principal stress σ1 and minor principal stress σ3 along the failure envelope, while the intermediate principal stress σ2 exerts no effect on failure conditions. The criterion offers practical advantages through mathematical simplicity and limited parameter requirements while maintaining reasonable analytical accuracy. Although the classical Mohr-Coulomb model does not explicitly account for cyclic degradation or strain accumulation effects under repeated loading cycles, established literature indicates that Mohr-Coulomb plasticity provides an adequate representation of soil response across the loading amplitudes and frequency ranges considered in this research.
The representative building investigated in the case study comprises two basement stories and five superstructure stories, designed to simulate multi-story structures featuring consistent element distributions across their floor plans. The structure was patterned after a pre-code 1970s reinforced concrete building in Huelva, Spain, sharing typical structural and constructive characteristics with buildings erected during that era. To simulate non-linear soil behavior in three dimensions, continuum models were developed in ABAQUS alongside supporting analyses in OpenSees. Interfacial contact between the concrete foundation and underlying soil bed was defined through surface-to-surface contact formulations. Normal contact behavior was defined as linear with contact stiffness taken as unity to prevent interpenetration. Tangential behavior was governed by a penalty contact formulation utilizing a friction coefficient of 0.4 to permit realistic interfacial sliding and slippage under dynamic seismic forces.
In the parametric analysis, the authors investigated free-field conditions and the combined two-basement five-story building across three geotechnical classes defined in the Egyptian Code of Practice (ECP 2012): Soil type B, Soil type C, and Soil type D. The time history analysis incorporated recorded earthquake motions—specifically Northridge 1994, Imperial Valley 1940, and San Fernando 1994 from the PEER database—and simulated ground motions generated using ECP 2012 response spectra types 1 and 2, which correspond respectively to Eurocode 8 spectra types 2 and 1. The numerical simulations evaluated five peak absolute accelerations: 0.075 g, 0.15 g, 0.20 g, 0.25 g, and 0.30 g. Kinematic boundary conditions were enforced along resting soil boundaries within ABAQUS to establish appropriate constraints, permitting systematic evaluation of peak absolute acceleration with depth and acceleration amplification.
The resulting acceleration depth profiles and amplification factors revealed clear trends across soil classes and ground motion intensities. Transitioning site conditions from class B to softer classes C and D increased amplification factor values by 11 percent and 20 percent across the studied acceleration range. In contrast, increasing peak absolute acceleration from 0.075 g to 0.30 g caused amplification factors to decrease by 5 percent to 20 percent across soil classes B, C, and D. For low peak absolute accelerations, amplification factors showed substantial increases across all soil types and earthquake records, particularly for site classes C and D. Furthermore, amplification factors calculated at accelerations of 0.075 g or higher were generally lower than values recommended in ECP 2012 for spectrum type 1, but consistently exceeded values recommended for spectrum type 2.
These outcomes demonstrate that soil amplification factors depend heavily on ground motion intensity, exposing significant limitations in Eurocode 8 and the Egyptian Code of Practice. Unlike the American ASCE 7-16 standard, which accounts for ground motion intensity variations through spectral site coefficients Fa and Fv across site classes C, D, and E, Eurocode 8 and ECP 2012 do not incorporate intensity-dependent adjustments. The authors recommend investigating the inclusion of peak acceleration dependency within future Eurocode provisions to achieve realistic structural evaluations. Finally, sensitivity analysis examining soil effective depth indicated that adopting an effective depth of 1.5 times foundation width is fully sufficient for calculating amplification factors, with larger depths altering results by at most 2 percent, consistent with literature values of 50 to 60 meters. Study authors noted that no datasets were generated or analysed.
Subject of Research: Soil-structure interaction and seismic soil amplification factors in reinforced concrete buildings
Article Title: Soil amplification factor for multi-story concrete buildings
Article References: Attia, R., Nour, M., Ibrahim, A., Abdel Hamid, S. G., & Fouda, M. A. (2026). Soil amplification factor for multi-story concrete buildings. Journal of Infrastructure Preservation and Resilience, 7(1), Article 22. https://doi.org/10.1186/s43065-026-00173-3
Image Credits: AI Generated
DOI: 10.1186/s43065-026-00173-3
Keywords: Soil-Structure Interaction, Soil Amplification Factor, Reinforced Concrete Buildings, Concrete Damage Plasticity, Mohr-Coulomb Criterion, Finite Element Analysis, ABAQUS, Peak Absolute Acceleration, Base Shear, Eurocode 8, Egyptian Code of Practice, ASCE 7-16, Time History Analysis, Dynamic Response, Foundation Flexibility, Pushover Analysis, Effective Soil Depth
Cite Scienmag News
Violet Maxwell. (November 19, 2026). Soil Amplification Factors Decrease Under Higher Ground Accelerations in Concrete Buildings. Scienmag. https://scienmag.com/soil-amplification-factors-decrease-under-higher-ground-accelerations-in-concrete-buildings/
Violet Maxwell. "Soil Amplification Factors Decrease Under Higher Ground Accelerations in Concrete Buildings." Scienmag, 19 November 2026, https://scienmag.com/soil-amplification-factors-decrease-under-higher-ground-accelerations-in-concrete-buildings/. Accessed 19 November 2026.
Violet Maxwell. "Soil Amplification Factors Decrease Under Higher Ground Accelerations in Concrete Buildings." Scienmag. November 19, 2026. https://scienmag.com/soil-amplification-factors-decrease-under-higher-ground-accelerations-in-concrete-buildings/