Two AI Tools Judging Breast Positioning in Screening Barely Agree

October 28, 2026
in Medicine
Ophelia Keating
By Ophelia Keating Scienmag Editorial Profile - Health Services Research
Reading Time: 4 mins read
0
Two AI Tools Judging Breast Positioning in Screening Barely Agree

Two AI Tools Judging Breast Positioning in Screening Barely Agree

65
SHARES
587
VIEWS
Share on FacebookShare on Twitter
ADVERTISEMENT

Two commercially available software systems designed to automatically grade breast positioning quality in digital breast tomosynthesis screening have turned out to be far from interchangeable, according to a new study published in European Radiology Experimental. When both tools scored the same 3,112 mammographic views from the same screening cohort, they landed on exactly the same Perfect, Good, Moderate or Inadequate rating in fewer than half of the images, and a statistical measure of agreement was close to what would be expected by chance.

The work, part of a project called PGMI-BENCH, was carried out by researchers including Gisella Gennaro and colleagues and drew on the RIBBS personalized breast screening program in Padua, Italy. The retrospective analysis included 778 women aged around 45 years, whose examinations had been recalled for further diagnostic assessment after double reading at the first screening round between January and December 2020. Seven examinations with incomplete software outputs were excluded, leaving 778 examinations with an equal split of craniocaudal and mediolateral oblique views.

The Perfect/Good/Moderate/Inadequate classification, known as PGMI, is widely used in screening programs to judge whether a mammographic image is properly positioned, since inadequate positioning can hide tissue, produce motion artifacts and skin folds, and ultimately affect cancer detection and recall rates. Human PGMI scoring is known to suffer from substantial inter- and intra-observer variability, which is precisely why automated tools have been developed: they promise objective, reproducible and scalable image quality assessment for audits, training and continuous monitoring of radiographer performance.

The two systems compared, however, work in fundamentally different ways. Software 1, Volpara Lab v2.0.3 from Lunit International, analyzes raw tomosynthesis projection images, the DICOM data labeled for processing. Software 2, b-box plus from b-rayZ in Zurich, analyzes processed synthetic 2D reconstructions generated from the same DBT acquisition, the data labeled for presentation. Both generate PGMI scores based on criteria such as breast tissue coverage, nipple position, pectoral muscle visualization, inframammary fold depiction and artifacts, but the exact definitions, thresholds and aggregation rules are proprietary and differ between the vendors.

The headline numbers are striking. Software 2 assigned 10.9 percent of images to the Inadequate category, while Software 1 flagged only 0.7 percent as Inadequate. Software 1 was more generous at the top of the scale, rating 21.9 percent of images Perfect compared with 12.9 percent for Software 2. Exact agreement between the two systems was just 48.2 percent, and the quadratic weighted kappa, a statistic that corrects for chance agreement, was a mere 0.044 with a 95 percent confidence interval of 0.006 to 0.085, indicating poor agreement. Agreement within one PGMI category was much higher at 87.7 percent, but the authors caution that this reflects ordinal proximity near category boundaries and should not be read as clinical equivalence.

The pattern of disagreement was structured rather than random. Images judged Inadequate by Software 2 were mostly reassigned as Moderate by Software 1, while many images rated Perfect by Software 2 were downgraded to Good or Moderate by Software 1. Disagreements spanning more than one category were uncommon. Agreement was better for mediolateral oblique views, with exact agreement of 57.3 percent, than for craniocaudal views, where it fell to 39.2 percent. The authors interpret this clustering around boundary categories as evidence of systematic differences in threshold definitions and feature weighting rather than fundamentally different detection of gross positioning errors.

Stratified analyses revealed how anatomy and acquisition parameters shaped the divergence. Using Software 1-derived breast density categories as a common reference, the largest inter-software differences appeared in the highest-density group, where Software 2 assigned substantially more Inadequate ratings and fewer Perfect ratings than Software 1. When stratified by breast volume quartiles, the greatest discrepancies occurred in the lowest-volume quartiles, while the highest-volume quartile showed the best agreement, with exact agreement around 51 percent, agreement within one category around 90 percent, and no statistically significant differences in category distributions.

Quantitative modeling reinforced these patterns. In univariate analysis, higher volumetric breast density was associated with lower PGMI scores in both systems, with a weak correlation for Software 1, a Spearman rho of minus 0.121, and a moderate correlation for Software 2, rho of minus 0.355. Breast volume showed positive associations with PGMI scores, again stronger for Software 2, rho of 0.361 versus 0.154. Multivariable ordinal logistic regression confirmed that increasing volumetric breast density and breast thickness were independently associated with lower odds of higher PGMI categories in both systems, while breast volume was associated with higher scores. Compression force showed an independent positive association with PGMI only in Software 2, and compression pressure was not significant in either model. Overall, Software 2’s outputs depended more strongly on breast composition and acquisition-related parameters.

The two systems also disagreed on which quality-control criteria to blame. In craniocaudal views, Software 1 most frequently flagged nipple alignment and posterior coverage, while Software 2 predominantly flagged pectoral muscle depiction and lateral parenchymal coverage. In mediolateral oblique views, both systems most often identified inframammary fold deficiencies, but Software 1 emphasized pectoral geometry while Software 2 more frequently flagged pectoral nipple-level adequacy and parenchymal coverage. Despite targeting similar conceptual domains of positioning quality, the two algorithms prioritized different anatomical features.

The authors are careful about what these findings do and do not show. Because no reference standard was available, the study cannot say which system is more accurate; it demonstrates relative disagreement between two complete end-to-end pipelines, including their different image inputs, rather than a direct comparison of decision rules. The cohort was a single screening population of relatively young women recalled after double reading, which may have introduced case enrichment and limits generalizability, and both algorithms were closed black boxes that could not be inspected internally. The authors conclude that automated PGMI systems are not interchangeable and call for harmonized definitions and validation against expert reader assessments, planned as the second phase of PGMI-BENCH, before such tools are deployed in routine clinical quality assurance.

Subject of Research: Agreement between two automated PGMI-based software tools for assessing breast positioning quality in digital breast tomosynthesis screening

Article Title: Comparison of two automated PGMI-based software tools for breast positioning quality assessment in DBT screening

Article References: Gennaro, G., Trazzi, S., Bordon, V., & Galli, V. (2026). Comparison of two automated PGMI-based software tools for breast positioning quality assessment in DBT screening. European Radiology Experimental, 10(1), Article 156. https://doi.org/10.1186/s41747-026-00825-9

Image Credits: AI Generated

DOI: 10.1186/s41747-026-00825-9

Keywords: digital breast tomosynthesis, PGMI, breast positioning, image quality assessment, screening, automated software, inter-rater agreement, breast density, mammography quality assurance, Volpara, b-box plus, artificial intelligence

Cite Scienmag News

Ophelia Keating. (October 28, 2026). Two AI Tools Judging Breast Positioning in Screening Barely Agree. Scienmag. https://scienmag.com/two-ai-tools-judging-breast-positioning-in-screening-barely-agree/

Ophelia Keating. "Two AI Tools Judging Breast Positioning in Screening Barely Agree." Scienmag, 28 October 2026, https://scienmag.com/two-ai-tools-judging-breast-positioning-in-screening-barely-agree/. Accessed 1 November 2026.

Ophelia Keating. "Two AI Tools Judging Breast Positioning in Screening Barely Agree." Scienmag. October 28, 2026. https://scienmag.com/two-ai-tools-judging-breast-positioning-in-screening-barely-agree/

Tags: AI-based mammogram image gradingArtificial Intelligenceautomated breast positioning assessment toolsautomated softwareb-box plusbreast densitybreast imaging software comparisonbreast positioningbreast positioning quality assessmentdigital breast tomosynthesisdigital breast tomosynthesis screeningimage quality assessmentimpact of breast positioning on diagnostic accuracyinter-rater agreementintersoftware agreement in breast screeningmammographic view quality evaluationmammography image quality metricsmammography quality assurancepersonalized breast screening programsPGMIPGMI breast positioning classificationretrospective breast imaging studyscreeningVolpara
Share26Tweet16
Previous Post

Rare Pineal Region Tumor Managed with Staged Surgery and Focal Radiotherapy in 63-Year-Old Man

Next Post

CAR-T Therapy for Brain Tumors Shows Early Promise and Persistent Barriers

Related Posts

ZNF207 shields glutamine transporter ASCT2 from degradation to fuel liver cancer growth
Cancer

ZNF207 shields glutamine transporter ASCT2 from degradation to fuel liver cancer growth

October 30, 2026
Most Ethiopian HIV patients on dolutegravir therapy show good knowledge, survey finds
Medicine

Most Ethiopian HIV patients on dolutegravir therapy show good knowledge, survey finds

October 30, 2026
Serum and urine protein biomarkers may sharpen prostate cancer detection beyond PSA
Medicine

Serum and urine protein biomarkers may sharpen prostate cancer detection beyond PSA

October 30, 2026
One gene locus flags atrial fibrillation risk after major surgery, UK Biobank study finds
Medicine

One gene locus flags atrial fibrillation risk after major surgery, UK Biobank study finds

October 30, 2026
Deep-learning CT reconstruction sharpens calcium visibility in phantom tests, but dose evens the score
Medicine

Deep-learning CT reconstruction sharpens calcium visibility in phantom tests, but dose evens the score

October 30, 2026
Pennywort Leaf Extract Lowers Blood Sugar in Diabetic Rats, Study Finds
Medicine

Pennywort Leaf Extract Lowers Blood Sugar in Diabetic Rats, Study Finds

October 30, 2026
Next Post
CAR-T Therapy for Brain Tumors Shows Early Promise and Persistent Barriers

CAR-T Therapy for Brain Tumors Shows Early Promise and Persistent Barriers

  • Mothers who receive childcare support from maternal grandparents show more optimized

    Mothers who receive childcare support from maternal grandparents show more parental warmth, finds NTU Singapore study

    27656 shares
    Share 11059 Tweet 6912
  • University of Seville Breaks 120-Year-Old Mystery, Revises a Key Einstein Concept

    1061 shares
    Share 424 Tweet 265
  • Bee body mass, pathogens and local climate influence heat tolerance

    682 shares
    Share 273 Tweet 171
  • Researchers record first-ever images and data of a shark experiencing a boat strike

    546 shares
    Share 218 Tweet 137
  • Groundbreaking Clinical Trial Reveals Lubiprostone Enhances Kidney Function

    531 shares
    Share 212 Tweet 133
Science

Embark on a thrilling journey of discovery with Scienmag.com—your ultimate source for cutting-edge breakthroughs. Immerse yourself in a world where curiosity knows no limits and tomorrow’s possibilities become today’s reality!

RECENT NEWS

  • Trademarks Meet Patents in New Method to Spot Technology Opportunities
  • Reddit self-declarations offer auditable labels for demographic inference
  • Scots pine needles map trace element pollution in Polish industrial town
  • Dual-blockchain scheme secures vehicle handovers without pre-shared keys

Categories

  • Agriculture
  • Anthropology
  • Archaeology
  • Athmospheric
  • Biology
  • Biotechnology
  • Blog
  • Bussines
  • Cancer
  • Chemistry
  • Climate
  • Earth Science
  • Editorial Policy
  • Marine
  • Mathematics
  • Medicine
  • Pediatry
  • Policy
  • Psychology & Psychiatry
  • Science Education
  • Science News
  • Social Science
  • Space
  • Technology and Engineering

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 5,150 other subscribers

© 2025 Scienmag - Science Magazine

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • HOME
  • SCIENCE NEWS
  • CONTACT US

© 2025 Scienmag - Science Magazine

Discover more from Science

Subscribe now to keep reading and get access to the full archive.

Continue reading