Wednesday, November 4, 2026
Science
No Result
View All Result
  • Login
  • HOME
  • SCIENCE NEWS
  • CONTACT US
  • HOME
  • SCIENCE NEWS
  • CONTACT US
No Result
View All Result
Scienmag
No Result
View All Result
Home Science News Chemistry

UHPLC–MS/MS Method Detects Trace Nitrosamine Impurity in Acebutolol Capsules

November 3, 2026
in Chemistry
Bethany Barker
By Bethany Barker Scienmag Editorial Profile - Catalysis
Reading Time: 4 mins read
0
UHPLC–MS/MS Method Detects Trace Nitrosamine Impurity in Acebutolol Capsules

UHPLC–MS/MS Method Detects Trace Nitrosamine Impurity in Acebutolol Capsules

65
SHARES
587
VIEWS
Share on FacebookShare on Twitter
ADVERTISEMENT

Nitrosamine impurities have become one of the most pressing quality-control challenges in modern pharmaceutical manufacturing, and a newly published study reports a validated analytical method designed to detect one of them in a widely used cardiovascular medicine. The research describes an Ultra-High Performance Liquid Chromatography–Tandem Mass Spectrometry (UHPLC–MS/MS) method for quantifying N-Nitroso Acebutolol (NNA), a nitrosamine drug substance-related impurity, in Acebutolol Hydrochloride Capsules. The work, published in BMC Chemistry, was carried out by Rajamani Dhanasekar, Vadivel Velmurugan, Sankham Devendran Rajendran and Viswas Raja Solomon.

Nitrosamine drug substance-related impurities, often abbreviated as NDSRIs, remain a major regulatory concern because of their potential genotoxicity. Conventional High-Performance Liquid Chromatography (HPLC) methods, though widely used in routine testing, have critical drawbacks for this class of contaminants, including limited sensitivity and poor selectivity, which make them inadequate for trace-level nitrosamine detection in complex pharmaceutical matrices such as capsule formulations.

To overcome these limitations, the research team developed and validated a UHPLC–MS/MS method specifically tailored to quantify NNA in the capsule formulation. The design of the method was guided by two toxicological frameworks: the European Medicines Agency’s carcinogenic potency categorization approach, which establishes a threshold of 1.25 µg/g for this impurity, and the International Council for Harmonization’s ICH M7 (R2) Mutagenicity Classification. By anchoring the analytical performance targets to these regulatory thresholds, the researchers ensured that the method could reliably distinguish acceptable from unacceptable impurity levels in the finished dosage form.

Validation was performed in accordance with ICH Q2 (R2), the current international guideline for analytical procedure validation. The method demonstrated strong performance across the key validation parameters. Relative standard deviation values were at or below 3.5 percent, indicating excellent precision across repeated measurements. The calibration curve showed a correlation coefficient of r² = 0.999, reflecting a highly linear response over the tested concentration range. The limit of quantitation was determined to be 0.646 µg/g, meaning the method can reliably quantify NNA at concentrations well below the 1.25 µg/g regulatory threshold. Recovery studies yielded values between 96 and 102 percent, confirming that the measurement is accurate across the analytical range.

Solution stability testing showed that prepared samples remained stable for up to 10 hours, an important practical consideration for laboratories that process batches of samples over extended analytical sessions. The researchers also applied the method to stability analysis of three expired batches of Acebutolol Hydrochloride Capsules. This testing confirmed the method’s ability to detect degradation without interference from the placebo matrix, a critical requirement for any stability-indicating procedure. The ability to analyse aged samples without matrix effects strengthens the case for the method’s use in routine quality-control laboratories.

All measured results in the study fell within the specification limit of 1.25 µg/g, with detected concentrations ranging from 0.210 to 0.509 µg/g across the tested batches. These findings support the conclusion that the analysed capsule batches met current regulatory expectations for NDSRI content. The authors note that although the limit of quantitation of 0.646 µg/g is higher than what has been reported for ultra-trace Active Pharmaceutical Ingredient analysis, it remains well below the EMA carcinogenic potency categorization threshold, ensuring regulatory compliance for the intended application.

The researchers are explicit about the scope of their method. It is designed for routine release and stability sample analysis of finished dosage forms, not for ultra-trace API analysis. This distinction matters because different analytical contexts demand different detection limits and sample preparation strategies. For finished capsule products, where the impurity is measured within a complex matrix of excipients and the regulatory threshold is 1.25 µg/g, a limit of quantitation below that threshold is sufficient for compliance testing. The authors position the method as the first validated UHPLC–MS/MS procedure for trace-level detection of NNA in Acebutolol Hydrochloride Capsules.

Beyond the core validation, the study integrated toxicological thresholds from EMA, the carcinogenic potency categorization approach and ICH M7 (R2) into the method design, with full ICH Q2 (R2) compliance and alignment to United States Pharmacopeia chapter <736> Mass Spectrometry standards. The stability analysis confirmed robustness and established the procedure’s suitability as a stability-indicating method, meaning it can detect changes in impurity levels over a product’s shelf life. Benchmarking through the Multicolored Analytical Chemistry profile highlighted analytical excellence, sustainability, practicality and Quality by Design integration, attributes the authors argue underscore the novelty of a reproducible, risk-based and future-ready platform for NDSRI monitoring in this capsule formulation.

The broader significance of this work lies in the growing regulatory demand for sensitive, validated methods capable of monitoring nitrosamine impurities in finished medicines. This study contributes a fully validated, stability-indicating UHPLC–MS/MS method that meets those demands for a specific cardiovascular capsule product, providing a template that may inform similar method development efforts for other nitrosamine drug substance-related impurities across the pharmaceutical industry.

Subject of Research: Development and validation of a UHPLC–MS/MS method for detecting the nitrosamine impurity N-Nitroso Acebutolol in acebutolol hydrochloride capsules

Article Title: Validation and stability analysis of N-Nitroso Acebutolol in acebutolol hydrochloride capsules using UHPLC–MS/MS for regulatory compliance and patient safety

Article References: Dhanasekar, R., Velmurugan, V., Rajendran, S. D., & Solomon, V. R. (2026). Validation and stability analysis of N-Nitroso Acebutolol in acebutolol hydrochloride capsules using UHPLC–MS/MS for regulatory compliance and patient safety. BMC Chemistry. https://doi.org/10.1186/s13065-026-01930-x

Image Credits: AI Generated

DOI: 10.1186/s13065-026-01930-x

Keywords: UHPLC–MS/MS, N-Nitroso Acebutolol, nitrosamine impurities, NDSRI, acebutolol hydrochloride capsules, ICH Q2 (R2), ICH M7 (R2), EMA carcinogenic potency categorization, pharmaceutical quality control, stability-indicating method, genotoxic impurity, regulatory compliance

Cite Scienmag News

Bethany Barker. (November 3, 2026). UHPLC–MS/MS Method Detects Trace Nitrosamine Impurity in Acebutolol Capsules. Scienmag. https://scienmag.com/uhplc-ms-ms-method-detects-trace-nitrosamine-impurity-in-acebutolol-capsules/

Bethany Barker. "UHPLC–MS/MS Method Detects Trace Nitrosamine Impurity in Acebutolol Capsules." Scienmag, 3 November 2026, https://scienmag.com/uhplc-ms-ms-method-detects-trace-nitrosamine-impurity-in-acebutolol-capsules/. Accessed 4 November 2026.

Bethany Barker. "UHPLC–MS/MS Method Detects Trace Nitrosamine Impurity in Acebutolol Capsules." Scienmag. November 3, 2026. https://scienmag.com/uhplc-ms-ms-method-detects-trace-nitrosamine-impurity-in-acebutolol-capsules/

Tags: Acebutolol capsule quality controlacebutolol hydrochloride capsulesEMA carcinogenic potency categorizationEuropean EMA guidelines for nitrosamine thresholdsgenotoxic impuritygenotoxicity of NDSRIsICH M7 (R2)ICH Q2 (R2)limitations of conventional HPLC for nitrosamine analysisN-Nitroso AcebutololNDSRInitrosamine impuritiesNitrosamine impururity detection in pharmaceuticalspharmaceutical impurity analysis in cardiovascular drugspharmaceutical quality controlregulatory challengesRegulatory complianceregulatory standards for nitrosaminessensitive detection of N-Nitroso Acebutololstability-indicating methodtrace level nitrosamine quantificationUHPLC-MS/MSUHPLC–MS/MS analytical methodvalidation of UHPLC–MS/MS method
Share26Tweet16
Previous Post

Repositioning During Surgery Tops Nursing Measures for Preventing Pressure Injuries, Bayesian Network Meta-Analysis Finds

Next Post

New add-on device turns uniaxial presses into cyclic rock shear testers

Related Posts

Magnetic carbon nitride photocatalyst strips dye from water under visible light
Chemistry

Magnetic carbon nitride photocatalyst strips dye from water under visible light

November 4, 2026
Justicia procumbens leaves and flowers curb gut inflammation while higher nutrient strength boosts lignan yields
Chemistry

Justicia procumbens leaves and flowers curb gut inflammation while higher nutrient strength boosts lignan yields

November 4, 2026
Fluoride-free etched MXene boosts cobalt MOF supercapacitor performance
Chemistry

Fluoride-free etched MXene boosts cobalt MOF supercapacitor performance

November 4, 2026
Triple-Interface Catalyst Pumps Hydrogen Fast in Neutral Seawater
Chemistry

Triple-Interface Catalyst Pumps Hydrogen Fast in Neutral Seawater

November 4, 2026
3D COMSOL Model of Industrial Water-Gas Shift Reactor Matches Ammonia Plant Data
Chemistry

3D COMSOL Model of Industrial Water-Gas Shift Reactor Matches Ammonia Plant Data

November 4, 2026
Soil Metals in China’s Daye Mining District Defy a Single Risk Driver
Earth Science

Soil Metals in China’s Daye Mining District Defy a Single Risk Driver

November 4, 2026
Next Post
New add-on device turns uniaxial presses into cyclic rock shear testers

New add-on device turns uniaxial presses into cyclic rock shear testers

  • Mothers who receive childcare support from maternal grandparents show more optimized

    Mothers who receive childcare support from maternal grandparents show more parental warmth, finds NTU Singapore study

    27656 shares
    Share 11059 Tweet 6912
  • University of Seville Breaks 120-Year-Old Mystery, Revises a Key Einstein Concept

    1061 shares
    Share 424 Tweet 265
  • Bee body mass, pathogens and local climate influence heat tolerance

    682 shares
    Share 273 Tweet 171
  • Researchers record first-ever images and data of a shark experiencing a boat strike

    546 shares
    Share 218 Tweet 137
  • Groundbreaking Clinical Trial Reveals Lubiprostone Enhances Kidney Function

    531 shares
    Share 212 Tweet 133
Science

Embark on a thrilling journey of discovery with Scienmag.com—your ultimate source for cutting-edge breakthroughs. Immerse yourself in a world where curiosity knows no limits and tomorrow’s possibilities become today’s reality!

RECENT NEWS

  • Rising and sinking continents may explain Earth’s missing rock record
  • Biodiversity Risk Emerges as a Hidden Financial Threat to Global Business
  • AI Risk Scoring Cuts Unnecessary Kidney Surgery in Large Randomized Trial
  • Pea Co-Product Shows Promise for Weaning Piglets’ Gut Health and Growth

Categories

  • Agriculture
  • Anthropology
  • Archaeology
  • Athmospheric
  • Biology
  • Biotechnology
  • Blog
  • Bussines
  • Cancer
  • Chemistry
  • Climate
  • Earth Science
  • Editorial Policy
  • Marine
  • Mathematics
  • Medicine
  • Pediatry
  • Policy
  • Psychology & Psychiatry
  • Science Education
  • Science News
  • Social Science
  • Space
  • Technology and Engineering

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 5,150 other subscribers

© 2025 Scienmag - Science Magazine

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • HOME
  • SCIENCE NEWS
  • CONTACT US

© 2025 Scienmag - Science Magazine

Discover more from Science

Subscribe now to keep reading and get access to the full archive.

Continue reading