Triangular Absorber Wall Roughness Maximizes Airflow in Vertical Solar Chimneys

November 18, 2026
in Science News
Audrey Campbell
By Audrey Campbell Scienmag Editorial Profile - Fluid Dynamics
Reading Time: 6 mins read
0
Triangular Absorber Wall Roughness Maximizes Airflow in Vertical Solar Chimneys

Triangular Absorber Wall Roughness Maximizes Airflow in Vertical Solar Chimneys

65
SHARES
587
VIEWS
Share on FacebookShare on Twitter
ADVERTISEMENT

A numerical investigation evaluating the fluid dynamics and heat transfer within vertical solar chimneys has revealed that applying structured surface roughness to the absorber plate substantially improves indoor natural ventilation performance compared to conventional smooth configurations. Conducted by researchers Fifi N. M. Elwekeel and Antar M. M. Abdala, the three-dimensional computational study analyzed how specific geometric profiles along the heated absorber plate alter buoyancy forces, thermal boundary layer development, and overall air discharge rates. Solar chimneys utilize solar thermal energy to heat an internal column of air, decreasing its density and driving natural convection currents that exhaust stale interior air and draw in fresh ambient air. While conventional designs typically rely on flat, unobstructed absorber plates, the authors observed that introducing triangular roughness shapes enhances turbulent mixing and significantly expands the active heat transfer surface area, yielding measurable improvements in total volumetric and mass airflow.

The computational domain developed for the investigation represented a vertical channel measuring 150 centimeters in height, 62 centimeters in length, and 20 centimeters in width, alongside varying air gaps spanning between 10 centimeters and 50 centimeters. Within this geometric framework, the researchers classified the absorber plate into four distinct structural conditions: a baseline smooth flat plate and three distinct roughened surface configurations designated as Case A, Case B, and Case C. Case A incorporated a flat plate modified with continuous triangular roughness elements across its heated surface. Case B retained the identical triangular roughness geometry but introduced a curved connection profile at the junction where each roughness element met the base plate. Case C evaluated a rectangular roughness profile featuring curved transitions along its base. In all configurations, the roughness geometry was structured as a function of chimney length to assess how localized flow disturbances modify the hydrodynamic and thermal behavior across the channel.

To model fluid behavior accurately, steady-state governing equations of continuity, momentum, and energy conservation were solved using the commercial computational fluid dynamics software ANSYS CFX with a high-resolution discretization scheme. The computational domain was meshed using structured hexagonal cells generated via ANSYS ICEM multi-block, incorporating ten specialized prism layers along the absorber surface and roughness contours to accurately capture velocity and thermal boundary layers. The researchers established grid independence across multiple mesh densities, determining that a grid system comprising 93,839 cells maintained numerical variations below 0.01 percent in computed airflow rates while keeping the dimensionless wall distance y-plus below one. The numerical model was validated against published experimental measurements and empirical predictions for a vertical chimney featuring a smooth absorber plate across heat fluxes ranging from 200 to 600 watts per square meter. Among four evaluated turbulence closures, including k-omega, shear stress transport, and renormalization group k-epsilon, the standard k-epsilon turbulence model yielded the highest predictive agreement, demonstrating an average deviation of only 0.4 percent from experimental data compared to deviations of 5.6 percent for k-omega, 15.4 percent for RNG k-epsilon, and 22.5 percent for SST.

Boundary conditions prescribed within the simulations modeled atmospheric air entering at an inlet temperature of 295 Kelvin in the ideal gas phase with medium turbulence intensity. Both the total pressure at the channel entrance and the static pressure at the chimney exit were maintained at zero gauge pressure, while the non-absorbing vertical and side walls satisfied non-slip adiabatic criteria. The absorber wall was subjected to uniform heat fluxes varied systematically between 200 and 600 watts per square meter, corresponding to Rayleigh numbers shifting from 3.9 times ten to the twelfth power up to 1.2 times ten to the thirteenth power. During initial testing phases, the opposing transparent glazing wall was maintained under an isothermal boundary condition set to the ambient temperature. Subsequently, the optimum absorber geometry was evaluated under both adiabatic and convective glazing boundary conditions to determine the influence of exterior thermal exchanges on internal flow dynamics.

Comparative analyses across the four absorber geometries demonstrated that Case A consistently produced superior ventilation rates and velocity profiles across all evaluated operational parameters. At a uniform heat flux of 600 watts per square meter and an internal air gap of 20 centimeters, the air flow rate generated by Case A surpassed that of Case B by 6.9 percent and exceeded Case C by 3.5 percent. Under these identical operating conditions, Case C achieved a higher discharge rate than Case B, whereas Case B performed very similarly to the baseline smooth wall. The researchers determined that the sharp-edged triangular peaks in Case A induce distinct fluid instabilities and localized vortices that disrupt the laminar sublayer, promoting vigorous fluid interchange between the heated wall grooves and the cooler core airflow without introducing the excessive hydraulic drag observed in configurations with rounded base transitions.

Evaluating internal temperature distributions along the chimney exit highlighted the fundamental thermodynamic mechanism responsible for the performance gains achieved by roughened absorbers. The localized fluctuations induced by the triangular profiles expand the effective heated contact area, intensifying convective heat transfer into the moving air column. For an operating heat flux of 500 watts per square meter at a Rayleigh number of 1.0 times ten to the thirteenth power, temperature contours revealed that the fluid in colder channel regions is drawn forcefully toward the heated wall by pronounced buoyancy differentials. In narrow channel gaps, such as 10 centimeters, the thermal boundary layer spans the majority of the channel width, causing higher bulk temperature increases. At a height of 140 centimeters above the inlet under a heat flux of 600 watts per square meter, Case A achieved an average temperature difference between the absorber and opposing wall that was 57 percent larger than Case C across both 10-centimeter and 20-centimeter channel widths. Furthermore, elevating the applied heat flux from 400 to 600 watts per square meter within Case A raised its average internal temperature difference by 37.6 percent.

Analysis of turbulent kinetic energy across the channel depth demonstrated that roughened plates generate elevated turbulence intensity adjacent to the heated boundary compared to smooth surfaces. Across horizontal cross-sections evaluated at heights of 50 centimeters and 140 centimeters above the entrance, turbulent kinetic energy peaked in immediate proximity to the absorber wall and progressively decayed toward the opposing glazing wall where cold fluid dominates. In Case A, intense turbulent kinetic energy and enhanced mixing spanned across both transverse spatial directions, raising fluid temperatures across the channel up to a distance of 35 centimeters from the wall before converging with the cooler ambient zone. These localized velocity and temperature fluctuations promote rapid thermal diffusion into the passing air stream, driving down air density and accelerating the buoyant vertical plume.

The physical spacing between the absorber wall and the exterior glazing, designated as the chimney air gap, exerted a decisive influence on fluid velocities and overall ventilation capacity. Testing channel widths of 10, 20, 30, 40, and 50 centimeters demonstrated that expanding the air gap initially enhances mass flow rates by reducing frictional resistance and accommodating larger volumes of buoyant fluid. Specifically, for Case A operating under a heat flux of 600 watts per square meter, increasing the channel gap to 40 centimeters established the optimum ventilation condition, producing mass flow rate increases of 71.9 percent, 52.8 percent, and 21.9 percent compared to channel gaps of 10, 20, and 30 centimeters, respectively. Furthermore, when widening the channel gap from 20 centimeters to 40 centimeters in Case A, the average exit velocity exceeded that of the baseline smooth chimney by 17.8 percent and 63.3 percent at the respective spacings.

However, the numerical simulations identified a critical operational limit when the air gap was widened to 50 centimeters under an isothermal glazing boundary condition. At this 50-centimeter spacing, the thermal boundary layer along the absorber wall fails to span the expansive passage, allowing dense, unheated ambient fluid to penetrate downward into the channel core from the exit. This reverse flow or backflow phenomenon establishes localized recirculating vortices at the chimney discharge that restrict the exiting air stream, causing the mass flow rate at a 50-centimeter gap to drop 2.5 percent below the rate achieved at a 40-centimeter gap. Velocity vector maps illustrated that while a narrow 10-centimeter gap entirely prevents reverse circulation by maintaining continuous positive upward velocity, the 40-centimeter gap minimizes the backflow zone relative to total channel area, thereby optimizing net natural ventilation discharge.

The study also examined the governing influence of glazing wall thermal boundary conditions on the ventilation performance of Case A at 600 watts per square meter. Simulating adiabatic, convective, and isothermal glazing surfaces demonstrated that an adiabatic glazing wall yields the highest overall air mass flow rate by preventing all conductive heat loss to the ambient environment. In contrast, the isothermal glazing condition produced the lowest ventilation rates due to cooler interior surface temperatures suppressing velocity gradients. Under convective glazing conditions, which the authors identified as the most realistic operational representation for actual architectural installations, the total airflow rate continued to increase steadily as the channel gap widened from 40 to 50 centimeters rather than decreasing, because moderate heat transfer through the glazing altered the internal pressure distribution and suppressed the severe discharge backflow observed under isothermal constraints.

Evaluating overall thermal performance using chimney efficiency formulations confirmed that Case A achieved the highest thermal conversion effectiveness alongside its superior flow rates. Because chimney efficiency is directly proportional to useful heat gain, which scales with both mass flow rate and net temperature rise, Case A consistently outperformed Cases B, C, and the smooth baseline across all heat flux inputs from 200 to 600 watts per square meter. At a 20-centimeter gap, raising the heat flux from 200 to 600 watts per square meter increased the average exit velocity of Case A by 51.6 percent. While the authors concluded that triangular roughness profiles offer substantial ventilation enhancements, they also noted design trade-offs, emphasizing that surface roughness introduces irregular temperature distributions and localized thermal stresses along the absorber plate, along with heightened frictional shear and potential flow recirculation if the channel gap is oversized.

Subject of Research: Numerical investigation of absorber wall roughness profiles on solar chimney ventilation performance

Article Title: Effect of wall roughness solar chimney absorber on natural ventilation rates

Article References: Elwekeel, F. N. M., & Abdala, A. M. M. (2026). Effect of wall roughness solar chimney absorber on natural ventilation rates. International Journal of Air-Conditioning and Refrigeration, 34(1), Article 12. https://doi.org/10.1007/s44189-026-00099-1

Image Credits: AI Generated

DOI: 10.1007/s44189-026-00099-1

Keywords: Solar Chimney, Natural Ventilation, Absorber Wall Roughness, Triangular Roughness, Computational Fluid Dynamics, ANSYS CFX, Mass Flow Rate, Buoyancy-Driven Flow, Chimney Air Gap, Heat Flux, Thermal Boundary Layer, Turbulent Kinetic Energy, k-epsilon Turbulence Model, Glazing Boundary Conditions, Backflow Phenomenon, Chimney Efficiency, Rayleigh Number

Cite Scienmag News

Audrey Campbell. (November 18, 2026). Triangular Absorber Wall Roughness Maximizes Airflow in Vertical Solar Chimneys. Scienmag. https://scienmag.com/triangular-absorber-wall-roughness-maximizes-airflow-in-vertical-solar-chimneys/

Audrey Campbell. "Triangular Absorber Wall Roughness Maximizes Airflow in Vertical Solar Chimneys." Scienmag, 18 November 2026, https://scienmag.com/triangular-absorber-wall-roughness-maximizes-airflow-in-vertical-solar-chimneys/. Accessed 18 November 2026.

Audrey Campbell. "Triangular Absorber Wall Roughness Maximizes Airflow in Vertical Solar Chimneys." Scienmag. November 18, 2026. https://scienmag.com/triangular-absorber-wall-roughness-maximizes-airflow-in-vertical-solar-chimneys/

Tags: Absorber Wall RoughnessANSYS CFXBackflow Phenomenonbuoyancy-driven flowChimney Air GapChimney Efficiencycomputational fluid dynamicsGlazing Boundary Conditionsheat fluxk-epsilon turbulence modelmass flow ratenatural ventilationRayleigh numbersolar chimneythermal boundary layerTriangular Roughnessturbulent kinetic energy
Share26Tweet16
Previous Post

Pediatric Cannabis Poisonings Rose Sharply While Hospital Social Management Remained Equitable

Next Post

JUND-DNAJB1-p21 Axis Drives Fibroblast Senescence and Inflammation in Sjögren’s Disease

Related Posts

Researchers Identify Novel Metabolic Pathways and Phenotypes Associated With PLOD3 Gene
Medicine

Researchers Identify Novel Metabolic Pathways and Phenotypes Associated With PLOD3 Gene

November 18, 2026
Work Engagement Predicts Reemployment Motivation in Older Danish Workers
Science News

Work Engagement Predicts Reemployment Motivation in Older Danish Workers

November 18, 2026
Spatial Microsimulation Framework Aligns With Established Local Health Estimates
Medicine

Spatial Microsimulation Framework Aligns With Established Local Health Estimates

November 18, 2026
Emergency Surgery Clears Ruptured Mediastinal Teratoma Spreading Toward Patient Neck
Medicine

Emergency Surgery Clears Ruptured Mediastinal Teratoma Spreading Toward Patient Neck

November 18, 2026
Genotype Feedback Linked to Lower Hazardous Drinking Scores in Municipal Employees
Medicine

Genotype Feedback Linked to Lower Hazardous Drinking Scores in Municipal Employees

November 18, 2026
Engineered Yarrowia lipolytica Produces Plant Polyketide Aloesone via Lipid Rewiring
Biotechnology

Engineered Yarrowia lipolytica Produces Plant Polyketide Aloesone via Lipid Rewiring

November 18, 2026
Next Post
JUND-DNAJB1-p21 Axis Drives Fibroblast Senescence and Inflammation in Sjögren’s Disease

JUND-DNAJB1-p21 Axis Drives Fibroblast Senescence and Inflammation in Sjögren’s Disease

  • Mothers who receive childcare support from maternal grandparents show more optimized

    Mothers who receive childcare support from maternal grandparents show more parental warmth, finds NTU Singapore study

    27656 shares
    Share 11059 Tweet 6912
  • University of Seville Breaks 120-Year-Old Mystery, Revises a Key Einstein Concept

    1061 shares
    Share 424 Tweet 265
  • Bee body mass, pathogens and local climate influence heat tolerance

    682 shares
    Share 273 Tweet 171
  • Researchers record first-ever images and data of a shark experiencing a boat strike

    546 shares
    Share 218 Tweet 137
  • Groundbreaking Clinical Trial Reveals Lubiprostone Enhances Kidney Function

    531 shares
    Share 212 Tweet 133
Science

Embark on a thrilling journey of discovery with Scienmag.com—your ultimate source for cutting-edge breakthroughs. Immerse yourself in a world where curiosity knows no limits and tomorrow’s possibilities become today’s reality!

RECENT NEWS

  • Researchers Identify Novel Metabolic Pathways and Phenotypes Associated With PLOD3 Gene
  • Work Engagement Predicts Reemployment Motivation in Older Danish Workers
  • Spatial Microsimulation Framework Aligns With Established Local Health Estimates
  • Emergency Surgery Clears Ruptured Mediastinal Teratoma Spreading Toward Patient Neck

Categories

  • Agriculture
  • Anthropology
  • Archaeology
  • Athmospheric
  • Biology
  • Biotechnology
  • Blog
  • Bussines
  • Cancer
  • Chemistry
  • Climate
  • Earth Science
  • Editorial Policy
  • Marine
  • Mathematics
  • Medicine
  • Pediatry
  • Policy
  • Psychology & Psychiatry
  • Science Education
  • Science News
  • Social Science
  • Space
  • Technology and Engineering

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 5,151 other subscribers

© 2026 Scienmag - Science Magazine

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • HOME
  • SCIENCE NEWS
  • CONTACT US

© 2026 Scienmag - Science Magazine

Discover more from Science

Subscribe now to keep reading and get access to the full archive.

Continue reading