Relatively low Nb and Ta additions balance corrosion and passive-film performance in Ti–Zr medium-entropy alloys

October 20, 2026
in Technology and Engineering
Denise Maddox
By Denise Maddox Scienmag Editorial Profile - Mechanical Engineering
Reading Time: 2 mins read
0
Nb and Ta Alloying Reshapes Corrosion Chemistry of Biomedical Ti–Zr Medium-Entropy Alloys

Nb and Ta Alloying Reshapes Corrosion Chemistry of Biomedical Ti–Zr Medium-Entropy Alloys

65
SHARES
587
VIEWS
Share on FacebookShare on Twitter
ADVERTISEMENT

Relatively low additions of niobium or tantalum provided a better balance of corrosion resistance, passive-current response, high-potential film stability and early cell adhesion in Ti–Zr-based medium-entropy alloys tested in phosphate-buffered saline (PBS), according to the study abstract. The research is an experimental materials-science study using in vitro electrochemical, surface-characterization and early cell-adhesion assessments; it does not establish clinical benefits for biomedical implants.

The investigators fabricated Ti–Zr–Nb and Ti–Zr–Ta alloy series with different niobium and tantalum contents by vacuum arc melting. Commercially pure titanium and Ti–6Al–4V served as reference materials. X-ray diffraction and electron backscatter diffraction were used to examine phase constitution and microstructure, while electrochemical measurements assessed corrosion behavior and passive-film responses in PBS. Gibbs free energy analysis and early cell-adhesion assessments were also performed, as summarized in the abstract.

Increasing the Nb or Ta content promoted a change from α′/α″/β multiphase structures toward β-dominated matrices, with Nb showing the stronger β-stabilizing effect. Corrosion resistance did not improve monotonically with increasing alloy content. Ta5 had the lowest corrosion current density among the investigated alloys, at 1.13 × 10−6 A cm−2, whereas Nb4 had the lowest passive current density among the designed alloys, at 2.60 × 10−5 A cm−2. Nb10 and Ta10 showed higher interfacial impedance near the open-circuit potential, but they also had higher corrosion and passive current densities and an earlier rise in current during anodic polarization. These measurements indicate that high interfacial impedance near open-circuit potential did not necessarily correspond to stable anodic passivation.

X-ray photoelectron spectroscopy identified passive films based on TiO₂ and ZrO₂ that also contained Nb- or Ta-containing oxide species. The reported Gibbs free energy analysis indicated that formation of the high-valence oxides was thermodynamically favorable. Overall, the abstract reports that relatively low Nb or Ta additions produced a better combined balance of the evaluated corrosion, passivation and early cell-adhesion properties than higher additions. Because the supplied evidence is an abstract rather than the full article, the precise protocols, uncertainty estimates, statistical results and detailed limitations of the cell-adhesion assessment are not available here; the findings should not be interpreted as evidence of implant performance or patient outcomes.

Subject of Research: Experimental evaluation of Nb and Ta alloying effects on corrosion, passive films and early cell adhesion in Ti–Zr medium-entropy alloys

Article Title: Effect of Nb and Ta alloying on corrosion behavior and passive film chemistry of biomedical Ti–Zr-based medium-entropy alloys in PBS solution

Article References: Hu, S., Wei, P., Liu, Y., Chen, Z., & Liu, D. (2026). Effect of Nb and Ta alloying on corrosion behavior and passive film chemistry of biomedical Ti–Zr-based medium-entropy alloys in PBS solution. Journal of Materials Science, 61(43), 34147-34172. https://doi.org/10.1007/s10853-026-13760-2

Image Credits: AI Generated

DOI: 10.1007/s10853-026-13760-2

Keywords: Ti–Zr medium-entropy alloys, niobium alloying, tantalum alloying, corrosion behavior, passive films, electrochemistry, XPS, cell adhesion, Effect, alloying, corrosion, behavior

Cite Scienmag News

Denise Maddox. (October 20, 2026). Relatively low Nb and Ta additions balance corrosion and passive-film performance in Ti–Zr medium-entropy alloys. Scienmag. https://scienmag.com/relatively-low-nb-and-ta-additions-balance-corrosion-and-passive-film-performance-in-ti-zr-medium-entropy-alloys/

Denise Maddox. "Relatively low Nb and Ta additions balance corrosion and passive-film performance in Ti–Zr medium-entropy alloys." Scienmag, 20 October 2026, https://scienmag.com/relatively-low-nb-and-ta-additions-balance-corrosion-and-passive-film-performance-in-ti-zr-medium-entropy-alloys/. Accessed 20 October 2026.

Denise Maddox. "Relatively low Nb and Ta additions balance corrosion and passive-film performance in Ti–Zr medium-entropy alloys." Scienmag. October 20, 2026. https://scienmag.com/relatively-low-nb-and-ta-additions-balance-corrosion-and-passive-film-performance-in-ti-zr-medium-entropy-alloys/

Tags: alloy composition optimization for biomedical applicationsalloyingbehaviorcell adhesioncorrosioncorrosion behaviorcorrosion resistanceEffectelectrochemical surface characterizationelectrochemistryin vitro cell adhesionmedium-entropy alloysNb and Ta alloying effectsniobium alloyingpassive current density in titanium alloyspassive filmspassive-film stabilityphase microstructure analysisphosphate-buffered saline corrosion testingtantalum alloyingTi–Zr medium-entropy alloysTi–Zr-based alloysXPSβ-phase stabilization in titanium alloys
Share26Tweet16
Previous Post

Systematic review finds adaptive AI-cybersecurity strategies and workforce gaps define national policy options

Next Post

Six lncRNAs show prognostic associations in a gastric cancer study with small tissue validation

Related Posts

AI and cybersecurity are locked in a two-way battle, major review finds
Technology and Engineering

Systematic review finds adaptive AI-cybersecurity strategies and workforce gaps define national policy options

October 20, 2026
AI Meets Circuit Theory to Pinpoint Solar Panel Faults With Precision
Technology and Engineering

Simulated hybrid framework identifies and localizes module-level faults in 3 × 5 photovoltaic array

October 20, 2026
Liquid Aluminum-Indium Alloy Defies Expectations Near the Miscibility Gap
Technology and Engineering

Research report: Diffusion in the liquid Al–In alloy when approaching the miscibility gap

October 20, 2026
AI Framework Teaches Wireless Receivers to Undo Channel Damage Image by Image
Technology and Engineering

Simulated wireless-channel tests show CLEAR improves image reconstruction under fading, Doppler shift and phase noise

October 20, 2026
Poultry Manure Extract, Humic Acid, and Dry Yeast Boost Lavender on Sandy Soils
Technology and Engineering

Combined organic biostimulants boost lavender growth and oil yield in greenhouse sandy-soil trial

October 20, 2026
AI Model Reads Supply Chains and News to Predict Corporate Financial Crises
Technology and Engineering

MFGCN machine-learning model outperforms baselines in global enterprise financial-crisis warning study

October 20, 2026
Next Post
Six Long Non-Coding RNAs Emerge as Powerful Prognostic Markers in Gastric Cancer

Six lncRNAs show prognostic associations in a gastric cancer study with small tissue validation

  • Mothers who receive childcare support from maternal grandparents show more optimized

    Mothers who receive childcare support from maternal grandparents show more parental warmth, finds NTU Singapore study

    27656 shares
    Share 11059 Tweet 6912
  • University of Seville Breaks 120-Year-Old Mystery, Revises a Key Einstein Concept

    1061 shares
    Share 424 Tweet 265
  • Bee body mass, pathogens and local climate influence heat tolerance

    682 shares
    Share 273 Tweet 171
  • Researchers record first-ever images and data of a shark experiencing a boat strike

    546 shares
    Share 218 Tweet 137
  • Groundbreaking Clinical Trial Reveals Lubiprostone Enhances Kidney Function

    531 shares
    Share 212 Tweet 133
Science

Embark on a thrilling journey of discovery with Scienmag.com—your ultimate source for cutting-edge breakthroughs. Immerse yourself in a world where curiosity knows no limits and tomorrow’s possibilities become today’s reality!

RECENT NEWS

  • Agronomic performance and leaf-morphological evaluation of basil (Ocimum basilicum L.) germplasm under the environmental conditions of Adana
  • Domain-specific stress profiles among dental, medical and non-medical students: a cross-sectional study
  • Systematic review links workplace blood screening economics to structured follow-up, with limited evidence on productivity
  • Six lncRNAs show prognostic associations in a gastric cancer study with small tissue validation

Categories

  • Agriculture
  • Anthropology
  • Archaeology
  • Athmospheric
  • Biology
  • Biotechnology
  • Blog
  • Bussines
  • Cancer
  • Chemistry
  • Climate
  • Earth Science
  • Editorial Policy
  • Marine
  • Mathematics
  • Medicine
  • Pediatry
  • Policy
  • Psychology & Psychiatry
  • Science Education
  • Science News
  • Social Science
  • Space
  • Technology and Engineering

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 5,150 other subscribers

© 2025 Scienmag - Science Magazine

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • HOME
  • SCIENCE NEWS
  • CONTACT US

© 2025 Scienmag - Science Magazine

Discover more from Science

Subscribe now to keep reading and get access to the full archive.

Continue reading