A modified humidity-dependent calibration methodology improves the measurement accuracy of a low-cost particulate matter sensor evaluated in long-term comparative field testing. In a study published in Aerosol and Air Quality Research, authors Márton L. Kiss, Marta Kiss, and Laura Veres investigated the operational performance of a PMS7003 sensor over an extended timeframe. The authors operated the low-cost sensor throughout a continuous one-year measurement period, directly comparing its output against data gathered from a reference-grade instrument operated within a national monitoring system.
The study specifically focuses on improving the measurement accuracy of PM10 by introducing a humidity-dependent correction approach. During the long-term testing period, the PMS7003 sensor provided particle number concentrations, reported in particles dm⁻3, for several different particle size classes.
To compensate for the hygroscopic growth of particulate matter under varying relative humidity conditions, the researchers applied a modified growing factor correction. Rather than using the conventional growing factor formula without alteration, the authors modified the formula and introduced an optimization procedure applied directly to its parameters. This parameter optimization was specifically conducted to minimize calibration error across the comparative measurement dataset.
The research team subsequently used the optimized model to recalculate the PMS7003 sensor output across the one-year evaluation period. This recalculation resulted in improved agreement between the low-cost sensor data and the reference measurements obtained from the national monitoring system instrument. By accounting for humidity-induced particle growth through mathematical optimization, the model effectively reduced the observational errors identified during the comparative evaluation.
According to the authors, the proposed approach demonstrates the significant potential of humidity-dependent calibration for improving the overall performance of low-cost particulate matter sensors. The research team concluded that refining sensor outputs through an optimized growing factor correction may directly support the future development of more reliable indicative air quality monitoring systems.
Subject of Research: Low-cost particulate matter sensor calibration using a modified growing factor approach
Article Title: Calibration of a Low-Cost Particulate Matter Sensor Using the Growing Factor
Article References: L.Kiss, M., Kiss, M., & Veres, L. (2026). Calibration of a Low-Cost Particulate Matter Sensor Using the Growing Factor. Aerosol and Air Quality Research. https://doi.org/10.1007/s44408-026-00179-2
Image Credits: AI Generated
DOI: 10.1007/s44408-026-00179-2
Keywords: particulate matter, PM10, low-cost sensors, PMS7003, sensor calibration, growing factor, hygroscopic growth, relative humidity, air quality monitoring, particle number concentration, comparative measurements, reference-grade instruments, national monitoring systems, calibration error minimization, parameter optimization, aerosol measurement, indicative monitoring