In an experimental investigation published in Scientific Reports, researchers found that incorporating unsoaked Light Expanded Clay Aggregate (LECA) as a coarse aggregate replacement between 20% and 25% provides the most favorable trade-off between compressive strength retention and concrete density reduction in M25 grade concrete. Laboratory tests demonstrated that substituting conventional coarse aggregate at these specific ratios reduced concrete density by 15% to 20% while achieving 28-day compressive strengths ranging from 17 to 19 MPa. In contrast, the control mix without aggregate substitution registered a baseline compressive strength of 31.45 MPa, demonstrating a clear trade-off between reduced material weight and mechanical capacity.
The experimental design encompassed multiple analytical stages to capture performance in both fresh and cured states.
For hardened concrete, the research team conducted an extensive suite of mechanical tests following 28 days of curing to assess the structural implications of lightweight aggregate substitution. The measurements quantified hardened density, compressive strength, split tensile strength, and flexural strength across all batch formulations. The experimental data revealed that a strong linear relationship exists between compressive strengths and concrete densities, supported by a correlation coefficient of R² ≈ 0.98. This high coefficient indicates that reductions in compressive capacity correlate directly and predictably with reductions in concrete density as LECA content increases across the tested mixture range.
The experimental mixes were subjected to water absorption tests, acid mass loss testing, sulphate mass loss testing, and Rapid Chloride Penetration Testing, commonly abbreviated as RCPT. Test observations confirmed that water absorption, chloride penetration ability, and mass loss under acid and sulphate exposure all increased as the LECA content rose within the concrete mixes. However, despite these observed increases in penetration and mass loss, the measured durability levels conformed to acceptable performance criteria specified by the American Concrete Institute in ACI 213R-14 guidelines.
To understand the fundamental physical mechanisms governing these mechanical and durability outcomes, the authors performed microstructural evaluations using Scanning Electron Microscopy combined with Energy Dispersive X-ray (SEM–EDX) analysis. The microscopic examination revealed that incorporating LECA produced a more refined interfacial transition zone between the aggregate particles and the surrounding cement paste. Notably, SEM–EDX analysis detected less accumulation of calcium hydroxide within this transition region, which helped establish stronger mechanical bonding between the aggregate and the paste.
Beyond mechanical integrity and durability, the research evaluated the sustainability impacts of substituting conventional aggregates with LECA by quantifying embodied energy and carbon dioxide (CO₂) emissions. The calculations showed that utilizing LECA increases the embodied energy of the concrete mix relative to conventional aggregate concrete. Nevertheless, the authors noted that this initial energetic increase is counterbalanced by significant density reductions of 15% to 20%, which lower the overall dead load imposed on an engineered structure.
In this window, the concrete preserves adequate compressive strengths of 17 to 19 MPa alongside compliant durability under ACI 213R-14 standards, while capturing the structural and dead-load advantages of a 15% to 20% density decrease.
Subject of Research: Engineering properties and durability of M25 concrete using LECA aggregate
Article Title: Engineering properties, durability, microstructural, and sustainability characteristics of concrete made with LECA aggregate as an alternative to conventional coarse aggregate
Article References: Nair, S. M., Anand, N., Andrushia, D., & Varghese, A. (2026). Engineering properties, durability, microstructural, and sustainability characteristics of concrete made with LECA aggregate as an alternative to conventional coarse aggregate. Scientific Reports. https://doi.org/10.1038/s41598-026-71504-3
Image Credits: AI Generated
DOI: 10.1038/s41598-026-71504-3
Keywords: M25 concrete, Light Expanded Clay Aggregate, LECA, coarse aggregate replacement, compressive strength, concrete density, split tensile strength, flexural strength, slump test, interfacial transition zone, SEM-EDX analysis, calcium hydroxide, Rapid Chloride Penetration Testing, acid mass loss, sulphate mass loss, ACI 213R-14, embodied energy, carbon dioxide emissions
Cite Scienmag News
Denise Maddox. (November 16, 2026). LECA Coarse Aggregate Lowers Concrete Density While Maintaining Acceptable Structural Durability. Scienmag. https://scienmag.com/leca-coarse-aggregate-lowers-concrete-density-while-maintaining-acceptable-structural-durability/
Denise Maddox. "LECA Coarse Aggregate Lowers Concrete Density While Maintaining Acceptable Structural Durability." Scienmag, 16 November 2026, https://scienmag.com/leca-coarse-aggregate-lowers-concrete-density-while-maintaining-acceptable-structural-durability/. Accessed 16 November 2026.
Denise Maddox. "LECA Coarse Aggregate Lowers Concrete Density While Maintaining Acceptable Structural Durability." Scienmag. November 16, 2026. https://scienmag.com/leca-coarse-aggregate-lowers-concrete-density-while-maintaining-acceptable-structural-durability/