In an observational case series of eight patients, researchers evaluated the utility of electrical impedance tomography for real-time functional lung monitoring during interventional pulmonary procedures. Traditional procedural monitoring during interventions such as bronchoscopy and thoracoscopy typically offers limited dynamic insight into immediate physiological changes. By utilizing continuous bedside impedance measurements, the study examined whether clinicians could evaluate immediate functional responses directly as interventions unfolded.
The evaluation involved eight patients undergoing specialized pulmonary interventions, including bronchoscopic tumor ablation, airway stent placement, and thoracoscopic adhesion release. Monitoring was conducted using a 16-electrode electrical impedance tomography belt positioned circumferentially at the level of the fifth intercostal space. The clinical team continuously recorded global ventilation levels, regional ventilation distributions, ventilation patterns, and overall lung symmetry across baseline, intraprocedural, and postprocedural periods.
During bronchoscopic tumor ablation, the imaging technique quantified immediate physiological improvements following the clearance of airway obstructions. In one treated patient, global ventilation values rose from a baseline of 218.09 to 327.07 following ablation. A second patient demonstrated an increase from 90.99 to 232.92. Both cases revealed substantial regional improvements within the treated lung areas, where specific regions of interest shifted from 1.31 to 124.39 in one patient and from 7.90 to 90.21 in the other.
The real-time monitoring system also tracked physiological responses associated with acute procedural complications and ongoing interventions. During an airway stent placement, the device captured a transient decrease in left lung ventilation while bleeding and active suctioning took place, which subsequently recovered once effective hemostasis was achieved. These dynamic recordings confirmed the system’s ability to mirror immediate shifts in ventilation and perfusion induced by acute airway events.
In patients undergoing bronchoscopic interventions for chronic airway obstruction, the tomography scans revealed a notable divergence between structural and functional restoration. Despite successful mechanical reopening of obstructed airways, the monitoring system demonstrated only modest immediate functional gains, indicating that chronic airway compromise may involve delayed physiological re-expansion rather than instantaneous recovery.
During thoracoscopic adhesiolysis, the monitoring platform documented regional re-ventilation while identifying persistent ventilation impairments linked to underlying pleural disease. The investigators concluded that electrical impedance tomography enabled differentiation between immediate anatomical success and functional physiological outcomes, providing an effective real-time complement to conventional endoscopic and structural imaging during thoracic interventions.
Subject of Research: Real-time electrical impedance tomography monitoring during interventional pulmonary procedures
Article Title: Real-time functional monitoring with electrical impedance tomography during bronchoscopic and thoracoscopic interventions
Article References: Shabani, N., Soltani, P., Abedini, A., Abbasi, M., Tabatabaei, S. M., Hashemian, S. M. R., Jafari, A., & Kiani, A. (2026). Real-time functional monitoring with electrical impedance tomography during bronchoscopic and thoracoscopic interventions. Journal of Cardiothoracic Surgery. https://doi.org/10.1186/s13019-026-04744-z
Image Credits: AI Generated
DOI: 10.1186/s13019-026-04744-z
Keywords: electrical impedance tomography, interventional pulmonology, bronchoscopy, thoracoscopy, lung ventilation, tumor ablation, airway stenting, adhesiolysis, regional ventilation, pulmonary monitoring, intraoperative imaging, ventilation distribution, thoracic surgery, airway obstruction, case series, physiological monitoring
Cite Scienmag News
Ophelia Keating. (November 20, 2026). Electrical Impedance Tomography Tracks Real-Time Lung Function During Pulmonary Interventions. Scienmag. https://scienmag.com/electrical-impedance-tomography-tracks-real-time-lung-function-during-pulmonary-interventions/
Ophelia Keating. "Electrical Impedance Tomography Tracks Real-Time Lung Function During Pulmonary Interventions." Scienmag, 20 November 2026, https://scienmag.com/electrical-impedance-tomography-tracks-real-time-lung-function-during-pulmonary-interventions/. Accessed 20 November 2026.
Ophelia Keating. "Electrical Impedance Tomography Tracks Real-Time Lung Function During Pulmonary Interventions." Scienmag. November 20, 2026. https://scienmag.com/electrical-impedance-tomography-tracks-real-time-lung-function-during-pulmonary-interventions/