Published in Scientific Reports, the experimental study addresses a specific limitation in steel-concrete composite structures: while saw-tooth connectors are highly efficient at transferring massive concentrated loads, they are inherently brittle and typically fail due to the surrounding concrete rather than the steel connector itself. By introducing an external confinement mechanism using double-headed studs, the team aimed to control the behavior of the concrete and enhance the overall structural efficiency of the connection.
The study focuses on the mechanical connection at the interface of steel-concrete composite members, which is critical for transferring longitudinal shear and resisting vertical uplift. Although headed shear studs are the most widely utilized connectors globally due to their reliability and automation, their performance can degrade under fatigue loads. To overcome these limitations, specialized geometries like the saw-tooth connector have been developed for high-load applications. The saw-tooth design uses a strut-and-tie model where shear loads are transferred through a fan-shaped set of compression struts along the toothed surface. However, this high rigidity classifies it as a brittle shear connector, with failure always governed by the surrounding concrete.
The novelty of this research lies in the use of double-headed studs as an external confinement mechanism. Unlike previous investigations that focused primarily on connector geometry without additional confinement, this study examines the influence of stud arrangement on stress distribution and failure behavior. The approach provides an alternative solution for improving bearing capacity in scenarios where conventional transverse reinforcement, such as stirrups, is restricted by the specimen geometry. The double-headed studs are designed to restrain the concrete and prevent splitting failure, with the heads providing confinement and the shanks carrying the vertical load.
The experimental investigation utilized a modified push-out test on three specimens with identical dimensions to those previously used to study unconfined saw-tooth connectors. The specimens consisted of slender reinforced concrete slabs measuring 1562 mm in length, 700 mm in width, and 100 mm in thickness. The concrete was designed with a compressive strength of 50 MPa, and the connectors were made of S355 steel. The double-headed studs had a shank diameter of 16 mm and a head diameter of 48 mm, positioned around the connector to confine the adjacent concrete area.
To monitor the performance of these confined connections, the researchers employed a comprehensive instrumentation setup. Twenty-three strain gauges were distributed on the concrete body of each specimen, and four additional strain gauges were fixed directly on the saw-tooth connector to measure stresses at the front and back. Ten linear variable displacement transducers (LVDTs) were used to measure the vertical displacement of the connector and the lateral displacement of the concrete. This extensive monitoring allowed the team to track the distribution of forces, the evolution of concrete strength through confinement, and the resulting failure mechanisms in detail.
The tests were conducted using a compression machine with a 5000 kN actuator. The load was applied at a rate of 35 kN per minute, and the values of strain were observed as the force increased. Preliminary loading cycles were repeated approximately 30 times up to a maximum load of 400 kN to ensure a uniform distribution of forces at the bottom of the slab. In the first test, CS1, a premature failure occurred at the bottom of the concrete slab due to the concentration of bearing forces, which prevented the full load-carrying capacity of the connector from being reached. To prevent this in subsequent tests, two C-shaped steel beams were introduced at the bottom of the slabs to provide additional confinement and stabilize the concrete.
The results from tests CS2 and CS3 showed that the addition of double-headed studs increased the load-bearing capacity by 20.1% compared to connectors without studs. The average scaled maximum force achieved in the confined tests was 2523 kN, whereas the average load capacity of the unconfined connector in previous tests was 2100 kN. The confinement boosted local concrete performance, with measurements indicating that the concrete strength near the stud heads reached approximately 1.2 times its uniaxial compressive strength. This increase in strength was calculated using Mander’s equations, suggesting that the concrete close to or under the heads of the studs experienced higher strength due to the confinement effect.
Despite the gains in strength and force distribution, the connection remains categorized as brittle. The failure was governed by concrete splitting in a wedge shape that propagated into a wider block than that observed in unconfined specimens. In specimen CS3, almost the entire width of the concrete specimen moved downward together with the connector, indicating the effectiveness of the studs in improving confinement. However, the connection still exhibited a sudden splitting failure, accompanied by the bending of the longitudinal reinforcement bars. The maximum relative displacement measured in the tests was approximately 1.4 mm, which is considerably lower than the 6 mm threshold defined by Eurocode 4 for classifying a shear connector as ductile.
The strain measurements revealed that the use of studs addressed the asymmetry and premature softening observed in unconfined tests. In the unconfined tests, the concrete elements lost strength earlier, causing the concrete along the connector to bear the load unevenly. In the confined tests, the concrete in front of the saw-tooth connector softened only after exceeding 2000 kN, and the distribution of stresses was more symmetrical. The strain values around the front part of the connector showed a significant difference between the confined and unconfined tests, with the confined specimens demonstrating a more uniform stress distribution. This symmetry is crucial for optimizing the load transfer mechanism and preventing premature concrete failure.
The study highlights that while double-headed studs are an effective method for optimizing bearing capacity and stress redistribution in high-load structural applications, they do not eliminate the brittle nature of the saw-tooth connector. The failure remains sudden, and the post-peak response could not be fully evaluated due to safety stops in the testing machine. The researchers note that the complete post-peak response, including the descending branch and residual bearing capacity, cannot be obtained from these tests. Therefore, the assessment of the connector behavior is based on the available load–displacement response and strain measurements up to the maximum load.
This experimental investigation provides valuable insights into the behavior of confined saw-tooth shear connectors in slender reinforced concrete slabs. The findings suggest that double-headed studs can be a viable solution for enhancing the performance of these connectors in applications where conventional reinforcement is not feasible. The study also sets the stage for future research, where a Finite Element model will be developed to further study the confined connection and investigate critical parameters that can optimize its structural performance. Further experimental investigations are planned to examine different stud arrangements and evaluate the behavior of the connection under cyclic and fatigue loading conditions.
The research contributes to the broader understanding of steel-concrete composite members and the mechanical connections that ensure their structural efficiency. By addressing the limitations of brittle failure in saw-tooth connectors, the study offers a practical approach to improving the safety and performance of high-load structural applications. The detailed instrumentation and careful experimental design allow for a comprehensive analysis of the forces and deformations involved, providing a solid foundation for future developments in shear connector technology.
Subject of Research: Experimental investigation of confined saw-tooth shear connectors using double-headed studs in slender concrete slabs
Article Title: Experimental investigation of confined saw-tooth shear connectors using double-headed studs in slender concrete slabs
Article References: Al-kroom, H., Reimer, A., & Schmid, V. (2026). Experimental investigation of confined saw-tooth shear connectors using double-headed studs in slender concrete slabs. Scientific Reports, 16(1), Article 40164. https://doi.org/10.1038/s41598-026-81531-9
Image Credits: AI Generated
DOI: 10.1038/s41598-026-81531-9
Keywords: Experimental, investigation, confined, saw-tooth, shear, connectors, double-headed, studs, slender, concrete, slabs
Cite Scienmag News
Gavin Prescott. (November 26, 2026). Double-headed studs boost shear connector capacity by 20%. Scienmag. https://scienmag.com/double-headed-studs-boost-shear-connector-capacity-by-20/
Gavin Prescott. "Double-headed studs boost shear connector capacity by 20%." Scienmag, 26 November 2026, https://scienmag.com/double-headed-studs-boost-shear-connector-capacity-by-20/. Accessed 26 November 2026.
Gavin Prescott. "Double-headed studs boost shear connector capacity by 20%." Scienmag. November 26, 2026. https://scienmag.com/double-headed-studs-boost-shear-connector-capacity-by-20/