Thursday, November 26, 2026
Science
No Result
View All Result
  • Login
  • HOME
  • SCIENCE NEWS
  • CONTACT US
  • HOME
  • SCIENCE NEWS
  • CONTACT US
No Result
View All Result
Scienmag
No Result
View All Result
Home Science News Medicine

Deep Learning Automates Brainstem MRI Planimetry in Multiple Sclerosis

November 26, 2026
in Medicine
Blake Davidson
By Blake Davidson Scienmag Editorial Profile - Data Science
Reading Time: 6 mins read
0
Deep Learning Automates Brainstem MRI Planimetry in Multiple Sclerosis

Deep Learning Automates Brainstem MRI Planimetry in Multiple Sclerosis

65
SHARES
587
VIEWS
Share on FacebookShare on Twitter
ADVERTISEMENT

A newly developed deep learning framework can automatically extract and quantify critical brainstem structures from magnetic resonance imaging scans of patients with multiple sclerosis in under half a second. Brain volume changes and structural atrophy within infratentorial regions represent crucial imaging biomarkers for tracking neurodegenerative progression and predicting irreversible disability in multiple sclerosis. Historically, evaluating these changes through magnetic resonance planimetry has required trained medical experts to manually locate anatomical landmarks and trace tissue boundaries on specialized image slices, a process that is time-consuming, prone to interrater variability, and difficult to standardize across clinical sites. By coupling an automated midsagittal plane extraction algorithm with a convolutional neural network trained to segment the midbrain and pons, the new automated pipeline derived comprehensive area and diameter measurements across four anatomical regions of interest in only 0.45 seconds per patient on a standard desktop computer, compared to 106.7 seconds required for manual delineation by clinical specialists.

Multiple sclerosis is a chronic neuroinflammatory and neurodegenerative disorder of the central nervous system in which early axonal damage and neuronal loss lead to progressive cerebral volume loss. Infratentorial involvement, particularly involving the midbrain and pons, is strongly associated with poorer clinical trajectories and sustained disability accumulation. While magnetic resonance volumetry provides valuable diagnostic insights into disease progression, its clinical implementation remains constrained by scanner variability, complex computational processing requirements, and limited routine accessibility. In contrast, magnetic resonance planimetry provides robust, readily obtainable geometric parameters derived from a single midsagittal plane using standard imaging software. Previous clinical investigations have demonstrated the prognostic utility of brainstem planimetric metrics, including midbrain and pontine cross-sectional areas, maximum anteroposterior diameters, and composite indices such as the magnetic resonance parkinsonism index, for assessing structural degradation and distinguishing distinct neurodegenerative phenotypes. However, wider clinical adoption has been prevented by reliance on manual expert measurements.

Planimetric evaluation focuses directly on the midsagittal plane, a well-defined anatomical slice that divides the human brain into left and right cerebral hemispheres. In conventional radiology workflows, expert raters visually identify this plane and manually trace polygonal boundaries around the midbrain and pons, an approach that is labor-intensive and susceptible to observer bias. To overcome these limitations, the investigators created an end-to-end automated workflow that eliminates manual slice selection and contour tracing. The proposed framework performs automated extraction of the midsagittal plane from three-dimensional magnetic resonance volumes, executes neural network-based segmentation of the midbrain and pons, algorithmically computes corresponding cross-sectional areas and anteroposterior diameters, and applies a task-specific loss function during training to address anatomical class imbalance. The primary objective was to benchmark this fully automated computational approach against expert manual planimetry, establishing whether deep learning can deliver reproducible, scalable infratentorial assessments across diverse multiple sclerosis subtypes and clinical scanner platforms.

The research team developed and evaluated the framework using a clinical dataset containing 227 three-dimensional magnetic resonance imaging volumes collected from 106 participants. The cohort consisted of 87 patients with multiple sclerosis representing various clinical subtypes—including clinically isolated syndrome, relapsing-remitting multiple sclerosis, secondary progressive multiple sclerosis, and primary progressive multiple sclerosis—alongside 19 healthy control subjects. Imaging acquisitions were performed at the Neuroimaging Core Facility across four 1.5-Tesla and two 3-Tesla Siemens scanners utilizing high-resolution T1-weighted magnetization-prepared rapid gradient echo sequences. To prevent data leakage and performance inflation, dataset splitting was performed strictly at the patient level rather than by individual scans. The multiple sclerosis training cohort contained 56 patients contributing 136 scans, the validation set comprised 9 patients with 18 scans, and the independent multiple sclerosis test cohort included 22 patients with 54 scans. An additional test group of 19 healthy controls provided 19 scans reserved exclusively for independent robustness testing.

Automating the planimetric pipeline required an algorithmic method to identify and extract the midsagittal plane from three-dimensional imaging volumes without human intervention. The researchers developed a technique combining the two-dimensional Radon transform with vertical symmetry metrics to calculate the three spatial degrees of freedom: yaw angle, roll angle, and perpendicular distance. The algorithm first selects an upper axial slice, calculates the center of mass of a thresholded binary image, and applies the Radon transform to compute projection averages along varying line angles and distances. Identifying the minimum intensity value within the transform determines the yaw angle and perpendicular offset, enabling rotational realignment of all axial slices with the coronal plane. Next, candidate roll angles between minus ten and positive ten degrees are evaluated on the central coronal slice to maximize vertical symmetry. Extracted midsagittal slices are subsequently resampled to 176 by 256 pixels, from which a standardized 128 by 128 pixel region of interest enclosing the brainstem is extracted.

To delineate brainstem structures within the extracted region of interest, the researchers deployed a standard U-Net architecture implemented in Python using the Keras deep learning library. The network incorporates convolutional layers with 3 by 3 and 1 by 1 filter kernels, max-pooling operations, and factor-of-two upsampling layers, encompassing 31,031,685 trainable parameters. Because the midbrain and pons occupy only a small fraction of the image frame, standard training runs the risk of generating trivial background-only segmentations due to severe spatial class imbalance. To ensure stable optimization, the authors combined Sørensen–Dice loss with a weighted binary cross-entropy loss function. This formulation incorporated a class- and contour-aware weighting factor that assigned higher mathematical penalties to target structure pixels and structural boundary contours. Four separate neural network models were trained across 30 epochs with a batch size of four, utilizing data augmentation routines that applied random pixel shifts, rotations up to fifteen degrees, and image zooms between 80 and 120 percent.

Expert manual measurements served as the clinical reference standard for training and validating the automated models. Under standardized protocols executed in MATLAB, human experts established two anatomical reference lines: an upper boundary connecting the inferior edge of the quadrigeminal plate to the superior pontine notch, and a parallel lower line passing through the inferior pontine notch to separate the pons from the medulla oblongata. Traced polygons provided midbrain and pontine areas, while maximum anteroposterior diameters were derived from the minor axes of ellipses fitted to the segmentations, excluding the collicular plate and pontine tegmentum. In the automated pipeline, cross-sectional areas were computed by multiplying predicted binary mask pixel counts by pixel dimensions. Automated diameters were obtained by applying a least-squares algorithm to fit an ellipse to the segmentation boundaries and calculating the minor axis. Discrepancies between automated predictions and manual tracings were evaluated using Sørensen–Dice overlap coefficients, absolute and relative area differences, absolute and relative diameter differences, and Hausdorff boundary distance metrics.

On the independent test dataset of 54 scans from 22 patients with multiple sclerosis, the automated segmentation system demonstrated high concordance with expert manual ground truth. For cross-sectional area segmentations, the U-Net achieved a mean Sørensen–Dice coefficient of 0.966 with a standard deviation of 0.011 for the pons, and a mean Dice coefficient of 0.941 with a standard deviation of 0.02 for the midbrain. Relative absolute area differences averaged 3.02 percent for pontine structures and 4.52 percent for the midbrain, while mean Hausdorff distances remained restricted to 1.59 millimeters and 1.24 millimeters. Ellipse-based diameter measurements similarly exhibited high spatial accuracy, yielding mean Dice coefficients of 0.925 for the pons and 0.908 for the midbrain, with average relative absolute diameter differences of 5.90 percent and 8.31 percent. Linear regression analysis confirmed strong statistical correlations between automated and manual evaluations, with squared correlation coefficients reaching 0.886 for pontine area, 0.878 for midbrain area, 0.794 for pontine diameter, and 0.780 for midbrain diameter.

Bland–Altman analyses revealed a slight tendency for the automated system toward area oversegmentation, with mean area differences of 9.33 square millimeters for the pons and 4.21 square millimeters for the midbrain. Conversely, automated diameter estimations displayed a mild negative bias, yielding minor axis diameters that were slightly shorter than manual measurements in 85 percent of pontine cases and 92 percent of midbrain cases. The investigators attributed this minor underestimation to the algebraic ellipse-fitting formulation rather than mask delineation errors, noting that the discrepancy did not cause threshold-based diagnostic misclassifications. Robustness analyses demonstrated that intravenous gadolinium-based contrast administration did not significantly alter segmentation performance, yielding non-significant differences with p-values of 0.5 or greater. In contrast, variations in slice thickness and matrix size produced measurable effects; scans acquired at 176 by 256 pixels with 1-millimeter thickness showed statistically significant improvements in midbrain Dice scores and relative area differences compared to 128 by 256 pixel scans with 1.2-millimeter thickness.

Stress testing with synthetic image noise confirmed that the framework maintained stable segmentation accuracy across moderate noise levels, with performance holding steady down to a signal-to-noise ratio of 15 before encountering a sharp failure threshold. In addition, testing on the 19 healthy control participants produced error metrics comparable to those observed in multiple sclerosis patients, achieving area Dice scores of 0.961 for the pons and 0.929 for the midbrain despite having received no training on healthy anatomy. Comparisons against two independent human raters with differing radiological experience confirmed that the deep learning framework maintained measurement consistency on par with inter-expert agreement. The authors noted that while rare vascular anomalies like basilar artery elongation could cause localized pontine misclassifications due to low tissue contrast, the automated system offers rapid, reproducible brainstem quantification that can be integrated directly into clinical picture archiving environments through standardized DICOM structured reporting.

Subject of Research: Automated deep learning framework for brainstem magnetic resonance imaging planimetry in multiple sclerosis

Article Title: Deep Learning Framework for Automated MRI Planimetry in Multiple Sclerosis

Article References: Mangesius, S., Schiefeneder, D., Schwab, M., Tiefenthaler, M., Deisenhammer, F., Haltmeier, M., & Gizewski, E. R. (2026). Deep Learning Framework for Automated MRI Planimetry in Multiple Sclerosis. International Journal of Biomedical Imaging, 2026(1), Article 4456355. https://doi.org/10.1155/ijbi/4456355

Image Credits: AI Generated

DOI: 10.1155/ijbi/4456355

Keywords: Multiple Sclerosis, MRI Planimetry, Deep Learning, Brainstem Atrophy, U-Net Architecture, Midsagittal Plane, Pons Segmentation, Midbrain Segmentation, Neuroimaging, Sørensen–Dice Coefficient, Expanded Disability Status Scale, Magnetic Resonance Imaging, Radon Transform, Automated Image Segmentation, Infratentorial Biomarkers, Disease Progression Monitoring, PACS Integration

Cite Scienmag News

Blake Davidson. (November 26, 2026). Deep Learning Automates Brainstem MRI Planimetry in Multiple Sclerosis. Scienmag. https://scienmag.com/deep-learning-automates-brainstem-mri-planimetry-in-multiple-sclerosis/

Blake Davidson. "Deep Learning Automates Brainstem MRI Planimetry in Multiple Sclerosis." Scienmag, 26 November 2026, https://scienmag.com/deep-learning-automates-brainstem-mri-planimetry-in-multiple-sclerosis/. Accessed 26 November 2026.

Blake Davidson. "Deep Learning Automates Brainstem MRI Planimetry in Multiple Sclerosis." Scienmag. November 26, 2026. https://scienmag.com/deep-learning-automates-brainstem-mri-planimetry-in-multiple-sclerosis/

Tags: Automated Image Segmentationbrainstem atrophydeep learningdisease progression monitoringExpanded Disability Status ScaleInfratentorial Biomarkersmagnetic resonance imagingMidbrain SegmentationMidsagittal PlaneMRI PlanimetryMultiple SclerosisneuroimagingPACS integrationPons SegmentationRadon TransformSørensen-Dice coefficientU-Net Architecture
Share26Tweet16
Previous Post

Perceived Usefulness and Institutional Trust Shape Malaysian Student Transit Intentions

Next Post

Climate Driven Shifts in Global Fishing Fleets Reshape Threats to Subsea Cables

Related Posts

Neurodivergent Healthcare Graduates Rewrite Professional Identity Norms Through Self-Authorship
Medicine

Neurodivergent Healthcare Graduates Rewrite Professional Identity Norms Through Self-Authorship

November 26, 2026
Baseline Handgrip Ratio Associated With Complete Tooth Loss in Two Longitudinal Cohorts
Medicine

Baseline Handgrip Ratio Associated With Complete Tooth Loss in Two Longitudinal Cohorts

November 26, 2026
Review Associates Mindfulness With Better Mental Health and Healthier Social Media Use
Medicine

Review Associates Mindfulness With Better Mental Health and Healthier Social Media Use

November 26, 2026
Amiodarone Impairs Metoprolol Clearance at Clinically Relevant Serum Concentrations
Medicine

Amiodarone Impairs Metoprolol Clearance at Clinically Relevant Serum Concentrations

November 26, 2026
Rare Breast Cancer Case Reveals Two Step Subtype Shift Under Chemotherapy Pressure
Cancer

Rare Breast Cancer Case Reveals Two Step Subtype Shift Under Chemotherapy Pressure

November 26, 2026
Prostate MRI Reporting Serves as Crucial Testbed for Language Model Safety
Medicine

Prostate MRI Reporting Serves as Crucial Testbed for Language Model Safety

November 26, 2026
Next Post
Climate Driven Shifts in Global Fishing Fleets Reshape Threats to Subsea Cables

Climate Driven Shifts in Global Fishing Fleets Reshape Threats to Subsea Cables

  • Mothers who receive childcare support from maternal grandparents show more optimized

    Mothers who receive childcare support from maternal grandparents show more parental warmth, finds NTU Singapore study

    27657 shares
    Share 11059 Tweet 6912
  • University of Seville Breaks 120-Year-Old Mystery, Revises a Key Einstein Concept

    1061 shares
    Share 424 Tweet 265
  • Bee body mass, pathogens and local climate influence heat tolerance

    682 shares
    Share 273 Tweet 171
  • Researchers record first-ever images and data of a shark experiencing a boat strike

    546 shares
    Share 218 Tweet 137
  • Groundbreaking Clinical Trial Reveals Lubiprostone Enhances Kidney Function

    531 shares
    Share 212 Tweet 133
Science

Embark on a thrilling journey of discovery with Scienmag.com—your ultimate source for cutting-edge breakthroughs. Immerse yourself in a world where curiosity knows no limits and tomorrow’s possibilities become today’s reality!

RECENT NEWS

  • Neurodivergent Healthcare Graduates Rewrite Professional Identity Norms Through Self-Authorship
  • Baseline Handgrip Ratio Associated With Complete Tooth Loss in Two Longitudinal Cohorts
  • Review Associates Mindfulness With Better Mental Health and Healthier Social Media Use
  • Melissa Burt Named 2027 American Meteorological Society President-Elect

Categories

  • Agriculture
  • Anthropology
  • Archaeology
  • Athmospheric
  • Biology
  • Biotechnology
  • Blog
  • Bussines
  • Cancer
  • Chemistry
  • Climate
  • Earth Science
  • Editorial Policy
  • Marine
  • Mathematics
  • Medicine
  • Pediatry
  • Policy
  • Psychology & Psychiatry
  • Science Education
  • Science News
  • Social Science
  • Space
  • Technology and Engineering

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 5,152 other subscribers

© 2026 Scienmag - Science Magazine

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • HOME
  • SCIENCE NEWS
  • CONTACT US

© 2026 Scienmag - Science Magazine

Discover more from Science

Subscribe now to keep reading and get access to the full archive.

Continue reading