A single-center randomized controlled clinical trial conducted at Damascus University has revealed that clear aligners induce less apical root resorption than conventional fixed appliances across multiple tooth types during orthodontic treatment for severe Class I crowding involving premolar extractions. The investigation demonstrated that while both treatment modalities produced measurable reductions in root length, the overall magnitude of apical shortening remained mild and well within established biological thresholds of safety. Across the evaluated dental arches, the mean apical root resorption ranged between 0.41 and 0.77 millimeters among patients treated with in-house clear aligners, compared to a range between 0.14 and 1.35 millimeters among individuals treated with conventional preadjusted edgewise fixed appliances. Following strict Bonferroni corrections for multiple comparisons, five distinct tooth categories displayed statistically significant reductions in root resorption in favor of clear aligners, specifically the maxillary central incisors, maxillary lateral incisors, maxillary canines, mandibular canines, and mandibular first molars. These findings indicate that clear aligners offer a biological safety profile regarding apical root conservation that is comparable, and in several anterior and posterior positions slightly superior, to traditional fixed bracket systems during complex premolar extraction mechanics.
Apical root resorption represents an unwanted yet recognized iatrogenic sequela of active orthodontic tooth movement characterized by the irreversible loss of hard cementum and dentin tissues at the anatomical root terminus. The biological cascade initiating root shortening is primarily associated with the concentration of sustained mechanical forces that compress the surrounding periodontal ligament, precipitating the localized development of a sterile hyalinized necrosis zone. This process initiates an inflammatory cascade that results in cementum and apical root resorption. Although incisors are inherently susceptible to apical resorption due to their single, tapered root configurations, the extent of tissue loss is heavily influenced by extrinsic mechanical factors such as force magnitude, delivery rhythm, movement vectors, and overall therapy duration. The historical transition of clear aligner technology from its initial conceptualization by Kesling in the 1940s and subsequent commercial digital emergence in the late 1990s into modern practice has expanded its clinical application from mild alignment to complex four-premolar extraction treatments. However, prior systematic reviews regarding aligner-induced root resorption had yielded conflicting conclusions largely derived from non-extraction cohorts, creating a need for prospective randomized evidence in complex extraction protocols.
To rigorously resolve this clinical question, the trial recruited young adult participants from patient pools seeking care at the Department of Orthodontics within the Faculty of Dentistry at Damascus University in Syria. Ethical approval was formally granted by the Local Research Ethics Committee under identification code DDS-8954-2021PG/SRC8871, institutional funding was provided directly by Damascus University under grant allocation 758137002DEN, and the trial was registered prospectively on the ClinicalTrials.gov registry under identifier NCT07236775. The participant recruitment window extended from November 2020 through March 2021, screening an initial cohort of 133 candidates before enrolling 40 eligible young adults aged between 18 and 25 years. The inclusion criteria required Class I malocclusion accompanied by severe dental crowding with a discrepancy exceeding 6 millimeters, requiring extraction of four first premolars. Eligible subjects possessed complete permanent dentition excluding third molars and showed no history of previous orthodontic intervention, baseline apical root defects, maxillofacial trauma, surgical history, systemic illnesses, or known hypersensitivity to medical thermoplastics.
The trial design adhered to a two-arm parallel-group framework governed by an equal one-to-one allocation ratio without protocol amendments during study execution. Simple randomization sequences were generated independently by an external researcher using Minitab 18.1 statistical software prior to participant enrollment, separating generation from recruitment. Concealment of group allocations was achieved through sequentially numbered, opaque, sealed envelopes that were unsealed exclusively after the bilateral extraction of all four first premolars was completed. Given the unmistakable aesthetic and structural distinctions between transparent thermoplastic aligners and labial metallic orthodontic brackets, blinding of treated participants and the principal treating clinician was operationally impossible. Nevertheless, complete methodological blinding was successfully maintained for both the diagnostic outcome assessor responsible for image analysis and the consulting data statistician. The final cohort comprised 16 males and 24 females with an overall mean age of 21.55 years, uniformly balanced between the clear aligner arm and the conventional fixed appliance arm without participant dropouts or protocol deviations.
Participants allocated to the clear aligner group received custom aligners manufactured using the 3DA digital system. Digital dental impressions were acquired using a Helios 600 intraoral scanner, followed by baseline zero aligner delivery and subsequent virtual setup manipulation within OnyxCeph3 planning software. Aligner biomechanics followed the Stepwise Activated Movements by Multiple Enhanced Re-anchorage protocol, which systematically organized treatment into three successive mechanical phases: an initial decrowding stage that prioritized sequential canine, lateral incisor, and central incisor alignment using posterior anchor units; an intermediate space-closure stage controlling premolar and molar reciprocal translation; and a final fine-tuning phase dedicated to occlusal refinement and posterior intercuspation. Programmed tooth movements were deliberately restricted to maximum increments of 0.25 millimeters for linear translation and 1.5 degrees for rotation per aligner setup. Models were 3D printed using a Phrozen DLP printer, and aligners were fabricated using 0.76-millimeter Zendura FLX aligner sheets and a Biostar thermoforming device. Aligners were initiated one week post-extraction, with composite attachments bonded at designated coordinates and patients instructed to wear each consecutive tray sequentially for fourteen days, yielding an average group treatment time of 24.27 months.
Patients assigned to the conventional fixed appliance group were treated using 0.022-inch Razor MBT prescription metallic brackets bonded to all maxillary and mandibular teeth one week after first premolar extractions. Anchorage conservation was actively supported in the maxillary arch through a transpalatal arch incorporating an acrylic Nance button, while the mandibular dentition was braced using a rigid lingual arch appliance. Orthodontic alignment and leveling progressed through a strictly standardized wire sequence consisting of initial 0.012-inch, 0.014-inch, 0.016-inch, and 0.016 by 0.022-inch nickel-titanium archwires, advancing subsequently to rectangular 0.017 by 0.025-inch nickel-titanium, 0.017 by 0.025-inch stainless steel, and ending with heavy 0.019 by 0.025-inch stainless steel working wires. Clinical appointments occurred regularly every four weeks to modify activations, swap ligatures, and monitor space-closure mechanics until comprehensive intercuspation and extraction site closure were confirmed. The mean treatment duration within the fixed appliance cohort was 27.20 months, during which pretreatment crowding values averaging 10.30 millimeters in the maxilla and 10.40 millimeters in the mandible were systematically resolved.
Outcome assessment centered upon absolute linear tooth length changes determined from standardized cone-beam computed tomography scans captured immediately before orthodontic bonding and following complete appliance removal. Scans were acquired on a Pax-i3D diagnostic system operating at identical exposure parameters of 85 kilovolts, 15 milliamperes, a 9-second scan time, a 150 by 150 millimeter field of view, and a 0.23-millimeter isometric voxel size. Using Ez3D-i Plus analytical software, the blinded investigator executed multiplanar reconstructions to reorient orthogonal slicing planes perfectly perpendicular to the longitudinal axis of each evaluated tooth. Linear measurements tracked the maximum perpendicular distance from the root apex to the anatomical incisal tip or respective cusp vertex, defining apical root resorption as baseline length minus final length. Measurement reliability was verified by re-evaluating sixteen randomly selected imaging volumes after a four-week interval; paired t-tests detected no systematic examiner bias, while intraclass correlation coefficients ranging between 0.951 and 0.995 confirmed excellent intra-examiner measurement consistency across anatomical landmarks.
Statistical evaluation in SPSS version 22.0 utilized independent two-sample t-tests alongside Bonferroni adjustments setting the threshold of statistical significance at P less than 0.005 to control familywise error rates across ten dental comparisons. Between-group mean difference estimates revealed statistically greater root length reduction under fixed appliances across five anatomical positions: maxillary central incisors exhibited a mean difference of negative 0.55 millimeters; maxillary lateral incisors demonstrated negative 0.53 millimeters; maxillary canines showed the largest divergence at negative 0.80 millimeters; mandibular canines reflected negative 0.39 millimeters; and mandibular first molars displayed negative 0.66 millimeters. The remaining tooth groups exhibited comparable resorption that did not satisfy Bonferroni thresholds, including mandibular central incisors and mandibular second premolars. Although maxillary second premolars displayed an estimated mean difference of 0.26 millimeters favoring fixed appliances, this difference failed to achieve corrected significance. Exploratory Pearson correlation analyses conducted within individual treatment cohorts showed no statistically significant relationship between total treatment duration and cumulative participant-level mean root resorption in either aligner or fixed groups.
The biological mechanisms underlying the reduced resorption observed with clear aligners appear linked to divergent force dynamics and intermittent activation patterns. Whereas conventional fixed archwires exert continuous mechanical loading across prolonged intervals, aligners generate intermittent forces that progressively dissipate across each fourteen-day wear cycle. This programmed force decay affords transient intervals of mechanical unloading, potentially allowing compressed periodontal tissues to experience cellular recovery and reducing the perpetuation of expansive hyalinized necrotic zones. From an empirical clinical standpoint, the absolute between-group differences identified in this trial, spanning 0.39 to 0.80 millimeters, fall comfortably below recognized thresholds of clinical harm. Root resorption below 2.0 to 2.5 millimeters is generally categorized as mild, clinically acceptable, and not usually associated with clinically significant adverse outcomes. These prospective measurements align consistently with prior observational literature by Gay, Aman, and Krieger reporting predominantly mild apical remodeling during aligner therapy, while extending biological safety verification to challenging premolar extraction protocols.
Throughout the entirety of active intervention and observation, no patient experienced adverse events, soft-tissue necrosis, severe pain requiring unscheduled appliance removal, or therapy termination attributable to appliance wear. Notwithstanding these favorable clinical outcomes, several methodological boundaries frame the interpretation of this trial. The investigation was conducted at a single academic center focusing exclusively on young adults presenting with severe Class I dental crowding, precluding direct extrapolation to adolescent cohorts, skeletal malocclusions, non-extraction protocols, or proprietary commercial aligner brands. Furthermore, three-dimensional alterations were quantified through reproducible linear distance metrics rather than comprehensive volumetric surface mapping, which may omit asymmetric peripheral root concavities. Finally, multiple tooth outcomes were analyzed without multilevel modeling of intra-subject clustering, underscoring that while aligners demonstrate biological safety, orthodontic treatment planning must weigh individual root morphology, anchorage demands, and patient compliance rather than relying solely on marginal differences in root resorption.
Subject of Research: Apical root resorption following premolar extraction treatment with clear aligners versus fixed appliances
Article Title: Evaluation of apical root resorption in young adults following orthodontic treatment of Class I malocclusion with severe crowding using clear aligners versus conventional fixed appliances: a randomized controlled trial
Article References: Jaber, S. T., Hajeer, M. Y., Burhan, A. S., Kara-Boulad, J. M., & Almasri, A. M. H. (2026). Evaluation of apical root resorption in young adults following orthodontic treatment of Class I malocclusion with severe crowding using clear aligners versus conventional fixed appliances: a randomized controlled trial. Progress in Orthodontics, 27(1), Article 48. https://doi.org/10.1186/s40510-026-00655-w
Image Credits: AI Generated
DOI: 10.1186/s40510-026-00655-w
Keywords: apical root resorption, clear aligners, fixed appliances, orthodontics, Class I malocclusion, severe crowding, premolar extraction, cone beam computed tomography, randomized controlled trial, tooth length, maxillary canines, mandibular first molars, periodontal ligament, orthodontic biomechanics, Damascus University, Bonferroni correction, intraoral scanning
Cite Scienmag News
Margaret Porter. (November 23, 2026). Clear Aligners Show Less Apical Root Resorption Across Five Tooth Types. Scienmag. https://scienmag.com/clear-aligners-show-less-apical-root-resorption-across-five-tooth-types/
Margaret Porter. "Clear Aligners Show Less Apical Root Resorption Across Five Tooth Types." Scienmag, 23 November 2026, https://scienmag.com/clear-aligners-show-less-apical-root-resorption-across-five-tooth-types/. Accessed 27 November 2026.
Margaret Porter. "Clear Aligners Show Less Apical Root Resorption Across Five Tooth Types." Scienmag. November 23, 2026. https://scienmag.com/clear-aligners-show-less-apical-root-resorption-across-five-tooth-types/