Home Science News

Temporal Bone CT Scans Can Preoperatively Estimate Stapes Prosthesis Length

November 23, 2026
in Science News
Ophelia Keating
By Ophelia Keating Scienmag Editorial Profile - Health Services Research
Reading Time: 6 mins read
0
Temporal Bone CT Scans Can Preoperatively Estimate Stapes Prosthesis Length

Temporal Bone CT Scans Can Preoperatively Estimate Stapes Prosthesis Length

65
SHARES
587
VIEWS
Share on FacebookShare on Twitter
ADVERTISEMENT

Preoperative high-resolution computed tomography of the temporal bone can provide useful estimates of stapes prosthesis length when intraoperative anatomical visualization proves difficult, according to a retrospective clinical review conducted by researchers at the Department of Otorhinolaryngology. Investigating 179 ears from 166 patients diagnosed with otosclerosis who underwent stapedotomy or stapedectomy between January 2014 and March 2023, the study team analyzed whether non-invasive imaging could reliably predict the necessary replacement implant dimensions before surgery. Otosclerosis is an insidious and progressive metabolic bone disease of the otic capsule where normal endochondral bone is replaced by spongy vascular bone, frequently causing conductive hearing loss through the mechanical fixation of the stapes footplate. Surgical intervention aims to restore sound conduction across the ossicular chain by inserting an artificial stapes prosthesis into a fenestra created in the stapes footplate. Because accurate prosthesis sizing is vital to postoperative hearing restoration and balance preservation, investigating whether cross-sectional imaging can reliably guide sizing decisions addresses a longstanding logistical challenge in reconstructive otology.

Surgical management of fenestral otosclerosis typically involves performing a stapedotomy or stapedectomy coupled with the careful selection and insertion of a stapes prosthesis. Establishing the precise distance between the lateral surface of the incus long process and the stapes footplate is essential for functional success, as an improper prosthesis length can directly cause surgical failure and poor patient outcomes. An excessively long prosthesis projects deeply into the vestibule, causing vestibular overstimulation, dizziness, and imbalance during physiological maneuvers like swallowing, sneezing, flying, or diving. Conversely, a prosthesis that is too short can result in sound distortion, inadequate acoustic energy transfer, and poor audiological gains. Long-term surgical records indicate that inappropriate prosthesis sizing and mechanical dislocation remain leading indications for revision procedures, which historically demonstrate lower success rates and progressive hearing loss with each subsequent surgical attempt. Although surgeons routinely employ intraoperative measuring gauges, intraoperative assessment can be severely hindered or rendered inaccurate during challenging surgical events such as facial nerve overhang, dehiscence, excessive bleeding, perilymph gushers, or footplate fracture.

To investigate whether axial high-resolution computed tomography can reliably predict prosthesis length before reaching the operating table, the research team examined 179 ears belonging to patients over fifteen years of age who had undergone primary stapes surgery with preoperative temporal bone imaging. Patients presenting with anomalous ossicles, hypermobile incus bones, prior revision surgeries, or imaging that failed predefined measurement quality criteria were excluded to maintain analytical consistency. Scans were captured on a GE Discovery 750 HD CT scanner using a bone algorithm kernel, direct 0.625 mm axial slices, a field of view of 20 to 25 cm, and a 512 by 512 matrix. The team utilized Centricity software version 2.0 with standardized bone window presets and a magnification factor of 2X on clinical workstations. To measure the anticipated prosthesis length, investigators identified specific axial slices displaying the lateral surface of the long process of the incus alongside the posterior crus of the stapes, tracing the linear distance from the incus lateral aspect to the stapes footplate immediately anterior to the posterior crus.

To ensure rigorous radiological evaluation and control for investigator bias, slice selection was performed independently by a principal investigator not involved in measurement collection. Measurements were then independently gathered by three distinct evaluators: two otolaryngologists with comparable levels of clinical experience, designated as observers 1 and 2, and a clinical radiologist, designated as observer 3. The retrospective cohort comprised 99 male patients (60%) and 67 female patients (40%), with 13 individuals undergoing bilateral surgical procedures. While otosclerosis literature generally reports a female predominance, the authors noted that higher male representation in this operated cohort likely reflected local health-seeking behaviors across working-age demographics. The overall cohort exhibited an average age of presentation of 37 years, with 36 percent of participants (60 individuals) situated between 30 and 40 years of age. Bilateral clinical involvement was documented in 93 percent of the patient cohort, while unilateral disease was observed in only 7 cases at the initial evaluation stage.

Audiological evaluations established a comprehensive baseline across all 179 operated ears, analyzing pure-tone air conduction and bone conduction thresholds across 500 Hz, 1000 Hz, and 2000 Hz alongside corresponding air-bone gaps. Patients presented with an average air conduction pure-tone threshold of 61 dB and an average bone conduction threshold of 22 dB, generating a mean air-bone gap of 39 dB. Hearing loss was the primary presenting symptom, with 56 percent of patients additionally reporting non-pulsatile, intermittent tinnitus and 10 percent presenting with associated vertigo. Preoperative tympanometric tracing demonstrated an A-type curve in approximately 70 percent of cases (126 ears), while only 34 cases displayed the classical low-compliance As-type curve typically attributed to ossicular stiffening. Speech audiometry revealed preserved central discriminatory capacity, with speech discrimination scores ranging from 70 to 100 percent across the cohort and 67 percent of patients achieving high scores between 91 and 100 percent.

Intraoperative surgical findings were systematically logged to document middle ear anatomy, prosthesis sizing, and operative complexities encountered across the 179 procedures. A total of 102 surgeries were conducted on the left ear using an endomeatal surgical approach, employing a Teflon prosthesis augmented with a vein tissue graft. Examination of surgical morphology classified stapes footplate involvement into three standard anatomical categories: 52 percent of cases (94 ears) presented with type 2 circumferential or biscuit-type footplates, while the remainder demonstrated type 1 localized lesions or type 3 obliterative otosclerosis. Documented intraoperative challenges that complicated direct visualization and physical measurement included three instances of facial nerve overhang directed toward the oval window, two cases exhibiting dehiscent facial nerves, and two occurrences of intraoperative perilymph gushers during footplate fenestration.

The mean radiological distance measured across all preoperative high-resolution computed tomography scans was 4.25 mm, spanning a range from 4.1 to 4.4 mm. This radiological mean aligned identically with the overall mean actual length of prostheses selected and placed intraoperatively. When examining statistical reproducibility, the two-way mixed-effects intraclass correlation coefficient across all three observers was 0.646 (95% CI: 0.545 to 0.727, p < 0.001), representing moderate overall inter-observer agreement. Pairwise evaluation demonstrated moderate reliability between observer 1 and observer 2 (ICC 0.57; 95% CI: 0.43 to 0.68) and between observer 2 and observer 3 (ICC 0.58; 95% CI: 0.43 to 0.68). However, agreement between observer 1 and observer 3 was poor (ICC 0.46; 95% CI: 0.27 to 0.59). When individual radiological estimates were compared against the actual length of the prosthesis selected intraoperatively, observers 1 and 2 displayed poor correlation, whereas the radiologist (observer 3) achieved moderate agreement with the true surgical length (ICC 0.50; 95% CI: 0.32 to 0.62).

Because commercial stapes prostheses and surgical measuring gauges are manufactured and trimmed in practical increments of 0.25 mm, the authors rounded all radiological measurements to the nearest 0.25 mm and repeated the comparative agreement analyses. The rounded intraclass correlation coefficient for all three readers remained moderate at 0.612 (95% CI: 0.502 to 0.701, p < 0.001). Inter-observer reliability between the two otolaryngologists was 0.54 (95% CI: 0.38 to 0.66), and reliability between otolaryngologist observer 2 and the radiologist was 0.58 (95% CI: 0.43 to 0.68). In contrast, the agreement between otolaryngologist observer 1 and the radiologist dropped to 0.36. Comparing the rounded values to the intraoperative prosthesis length revealed continued poor correlation for observers 1 and 2, but maintained moderate correlation for the radiologist with an ICC of 0.49 (95% CI: 0.32 to 0.63). The averaged measurements of all three observers yielded a poor correlation with the placed prosthesis (ICC 0.46), and the pooled otolaryngologist values correlated poorly as well (ICC 0.35).

Evaluating the exact numerical concordance between the radiologist’s rounded measurements and the final intraoperative prosthesis length demonstrated that 43 percent of cases (78 ears) matched the exact physical prosthesis size placed by the surgeon. Furthermore, 22 percent of cases (39 ears) yielded an imaging measurement that was 0.25 mm larger than the intraoperative prosthesis, while 16 percent of cases (29 ears) measured 0.25 mm smaller than the surgical implant. Combined together, more than 80 percent of all operated cases fell within a tight margin of plus or minus 0.25 mm of the true intraoperative length. This distribution confirms that when evaluated by an experienced radiologist, temporal bone computed tomography reliably tracks the physical dimensions of the middle ear ossicular gaps.

Despite these favorable predictive margins from the radiologist, the authors emphasized clear limitations that prevent preoperative computed tomography from replacing conventional direct intraoperative measurements. The pronounced disparity in predictive accuracy between the radiologist and the two otolaryngologists suggests that routine software manipulation, windowing precision, and slice interpretation require specialized radiological training to yield reliable millimeter-level calculations. Moreover, the presence of poor inter-observer agreement between certain evaluators underscores that computed tomography cannot guarantee standardized millimeter accuracy across different clinical readers. The study concluded that direct physical measurement using an intraoperative gauge remains the definitive gold standard during routine stapedotomy and stapedectomy. Nevertheless, in complex operative scenarios where direct access to the oval window niche is obstructed by facial nerve overhang, brisk bleeding, or a perilymph gusher, preoperative measurements performed by a dedicated radiologist offer a dependable sizing estimate to guide the surgical team.

Subject of Research: Preoperative stapes prosthesis length estimation using temporal bone high-resolution computed tomography in otosclerosis

Article Title: The use of high-resolution ct (HRCT) of the temporal bone for accurate preoperative prediction of stapes prosthesis length in patients with otosclerosis

Article References: Sunil, N., Philip, A., Juanita Job, A., Mary Augustine, A., Susan Regi, S., Deena Mammen, M., & P. G., M. (2026). The use of high-resolution ct (HRCT) of the temporal bone for accurate preoperative prediction of stapes prosthesis length in patients with otosclerosis. The Egyptian Journal of Otolaryngology, 42(1), Article 281. https://doi.org/10.1186/s43163-026-01267-1

Image Credits: AI Generated

DOI: 10.1186/s43163-026-01267-1

Keywords: otosclerosis, stapedotomy, stapedectomy, stapes prosthesis, temporal bone, high-resolution CT, HRCT, incus, stapes footplate, conductive hearing loss, audiology, air-bone gap, intraclass correlation coefficient, radiology, middle ear surgery, carhart notch

Cite Scienmag News

Ophelia Keating. (November 23, 2026). Temporal Bone CT Scans Can Preoperatively Estimate Stapes Prosthesis Length. Scienmag. https://scienmag.com/temporal-bone-ct-scans-can-preoperatively-estimate-stapes-prosthesis-length/

Ophelia Keating. "Temporal Bone CT Scans Can Preoperatively Estimate Stapes Prosthesis Length." Scienmag, 23 November 2026, https://scienmag.com/temporal-bone-ct-scans-can-preoperatively-estimate-stapes-prosthesis-length/. Accessed 23 November 2026.

Ophelia Keating. "Temporal Bone CT Scans Can Preoperatively Estimate Stapes Prosthesis Length." Scienmag. November 23, 2026. https://scienmag.com/temporal-bone-ct-scans-can-preoperatively-estimate-stapes-prosthesis-length/

Tags: air-bone gapaudiologycarhart notchconductive hearing losshigh-resolution CTHRCTincusintraclass correlation coefficientmiddle ear surgeryotosclerosisradiologystapedectomystapedotomystapes footplatestapes prosthesistemporal bone
Share26Tweet16
Previous Post

International Survey Finds Stoma Choices in Rectal Cancer Surgery Vary Widely

Next Post

GLP-1 Receptor Agonists Cut Heart Failure Events in HFpEF Without Lowering Mortality

Related Posts

Participatory Thermal Walks Reveal How Sensory Cues Shape Urban Heat Perceptions
Science News

Participatory Thermal Walks Reveal How Sensory Cues Shape Urban Heat Perceptions

November 23, 2026
Diabetic Migrant Workers in Qatar Face Substantial Depression and Anxiety Symptoms
Medicine

Diabetic Migrant Workers in Qatar Face Substantial Depression and Anxiety Symptoms

November 23, 2026
Platform Algorithms Expand Topical Variety While Narrowing Underlying Semantic Information Delivery
Science News

Platform Algorithms Expand Topical Variety While Narrowing Underlying Semantic Information Delivery

November 23, 2026
Advanced Water Oxidation Destroys Carbamazepine but Leaves Residual Toxicity in Frog Embryos
Technology and Engineering

Advanced Water Oxidation Destroys Carbamazepine but Leaves Residual Toxicity in Frog Embryos

November 23, 2026
Lower County Household Income Linked to Increased Out-of-Hospital Cardiac Deaths in Ohio
Medicine

Lower County Household Income Linked to Increased Out-of-Hospital Cardiac Deaths in Ohio

November 23, 2026
RNA Binding Protein HuR Coordinates Cytokine Synthesis via Granules on Endoplasmic Reticulum
Science News

RNA Binding Protein HuR Coordinates Cytokine Synthesis via Granules on Endoplasmic Reticulum

November 23, 2026
Next Post
GLP-1 Receptor Agonists Cut Heart Failure Events in HFpEF Without Lowering Mortality

GLP-1 Receptor Agonists Cut Heart Failure Events in HFpEF Without Lowering Mortality

  • Mothers who receive childcare support from maternal grandparents show more optimized

    Mothers who receive childcare support from maternal grandparents show more parental warmth, finds NTU Singapore study

    27656 shares
    Share 11059 Tweet 6912
  • University of Seville Breaks 120-Year-Old Mystery, Revises a Key Einstein Concept

    1061 shares
    Share 424 Tweet 265
  • Bee body mass, pathogens and local climate influence heat tolerance

    682 shares
    Share 273 Tweet 171
  • Researchers record first-ever images and data of a shark experiencing a boat strike

    546 shares
    Share 218 Tweet 137
  • Groundbreaking Clinical Trial Reveals Lubiprostone Enhances Kidney Function

    531 shares
    Share 212 Tweet 133
Science

Embark on a thrilling journey of discovery with Scienmag.com—your ultimate source for cutting-edge breakthroughs. Immerse yourself in a world where curiosity knows no limits and tomorrow’s possibilities become today’s reality!

RECENT NEWS

  • Participatory Thermal Walks Reveal How Sensory Cues Shape Urban Heat Perceptions
  • Diabetic Migrant Workers in Qatar Face Substantial Depression and Anxiety Symptoms
  • Platform Algorithms Expand Topical Variety While Narrowing Underlying Semantic Information Delivery
  • Advanced Water Oxidation Destroys Carbamazepine but Leaves Residual Toxicity in Frog Embryos

Categories

  • Agriculture
  • Anthropology
  • Archaeology
  • Athmospheric
  • Biology
  • Biotechnology
  • Blog
  • Bussines
  • Cancer
  • Chemistry
  • Climate
  • Earth Science
  • Editorial Policy
  • Marine
  • Mathematics
  • Medicine
  • Pediatry
  • Policy
  • Psychology & Psychiatry
  • Science Education
  • Science News
  • Social Science
  • Space
  • Technology and Engineering

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 5,151 other subscribers

© 2026 Scienmag - Science Magazine

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • HOME
  • SCIENCE NEWS
  • CONTACT US

© 2026 Scienmag - Science Magazine

Discover more from Science

Subscribe now to keep reading and get access to the full archive.

Continue reading