Thursday, October 29, 2026
Science
No Result
View All Result
  • Login
  • HOME
  • SCIENCE NEWS
  • CONTACT US
  • HOME
  • SCIENCE NEWS
  • CONTACT US
No Result
View All Result
Scienmag
No Result
View All Result
Home Science News Medicine

Preclinical SPECT scanner cuts 177Lu dose needed for sharp mouse tumour imaging

October 28, 2026
in Medicine, Technology and Engineering
Nathaniel Bowman
By Nathaniel Bowman Scienmag Editorial Profile - Precision Oncology
Reading Time: 3 mins read
0
Preclinical SPECT scanner cuts 177Lu dose needed for sharp mouse tumour imaging

Preclinical SPECT scanner cuts 177Lu dose needed for sharp mouse tumour imaging

65
SHARES
587
VIEWS
Share on FacebookShare on Twitter
ADVERTISEMENT

Researchers have mapped out how little radioactive tracer a mouse cancer study actually needs, reporting that a small-animal SPECT scanner can produce usable tumour images with as little as 4 megabecquerels of a 177Lu-labelled peptide for short-term imaging, and 8 megabecquerels for studies stretching out to a full week after injection. The finding, published as open-access original research in EJNMMI Physics, comes from a systematic performance evaluation of the γ-CUBE preclinical SPECT system, a scanner designed for theranostic studies in laboratory animals.

The study, led by Davide Tosoni and colleagues, set out with two goals: to characterise how the γ-CUBE performs with both 99mTc, a workhorse of nuclear medicine imaging, and 177Lu, a radionuclide increasingly central to peptide receptor radionuclide therapy, and to determine the minimum administered activity of a novel 177Lu-labelled peptide in a mouse cancer model without compromising image quality.

System performance was assessed in terms of uniformity, spatial resolution and contrast-to-noise ratio, using syringes and Derenzo phantoms, with 177Lu compared directly against 99mTc. The scanner accepts three interchangeable collimators, each with a different trade-off between sensitivity and resolution: a general-purpose-rat collimator (GP-R), a general-purpose-mouse collimator (GP-M) and a high-sensitivity-mouse collimator (HS-M). The team tested all three while varying the number of iterations of the reconstruction algorithm, an important variable because iterative reconstruction can sharpen images but also degrade uniformity as iterations accumulate.

The uniformity results illustrate that trade-off. With 99mTc, integral uniformity measured 18.3 percent for the GP-R collimator, 23.6 percent for GP-M and 17.3 percent for HS-M at 50 iterations. Increasing the number of iterations degraded uniformity, and 99mTc consistently showed better uniformity values than 177Lu across the tested conditions.

Spatial resolution followed a different pattern. The GP-M collimator resolved all Derenzo rods, down to the finest 1 millimetre rods, for both radionuclides. The HS-M collimator resolved rods of 1.6 millimetres and larger at 500 iterations, while the GP-R collimator resolved rods of at least 1.4 millimetres for 99mTc and at least 2 millimetres for 177Lu at 500 iterations. These phantom measurements define the practical limits of what each collimator configuration can distinguish in a small animal.

Quantitative accuracy for 177Lu was determined at 50 iterations using a biomimetic mouse phantom and polypropylene tubes filled with activity concentrations ranging from 0.095 to 2.36 megabecquerels per millilitre. The HS-M collimator delivered superior quantitative accuracy, exceeding 90 percent, for all tested activity concentrations. That accuracy figure is central to the scanner’s usefulness for biodistribution studies, where the goal is not just to see where a tracer accumulates but to measure how much of it is there.

To establish the activity threshold, the researchers injected three tumour-bearing mice with 16.0 plus or minus 1.3 megabecquerels of the 177Lu-labelled peptide and scanned them with the HS-M collimator at different time points after injection. Lower activities, from 1.6 to 12 megabecquerels, were then simulated by retrospective reconstructions of the acquired data. Tumour contrast-to-noise ratio was calculated at 48 hours and 168 hours post-injection, and image quality was assessed by five independent readers using a 5-point scale.

The results showed that tumour contrast-to-noise ratio worsened as injected activity was reduced, as expected. The panel of readers and the CNR analysis converged on 8 megabecquerels as the threshold for good image quality up to 7 days after injection, while 4 megabecquerels was deemed acceptable for short-term studies of less than 48 hours. In other words, the injected activity of the 177Lu-peptide in the experimental paradigm used for the study can be significantly reduced while still maintaining adequate image quality for longitudinal biodistribution studies.

On the basis of these measurements, the authors conclude that the γ-CUBE system offers versatile performance for imaging with both 99mTc and 177Lu. They recommend the HS-M collimator for low-activity studies, and they identify 50 iterations as the best compromise for routine applications. The study is limited to the preclinical setting and the specific experimental paradigm described, so the thresholds reported here apply to this scanner, these collimators and this peptide rather than to clinical imaging. The article was published on 5 October 2026 as a peer-reviewed, accepted manuscript shared ahead of final copyediting.

Subject of Research: Performance evaluation of a preclinical SPECT scanner and optimization of imaging protocols for 177Lu-labelled radiopharmaceuticals in mouse cancer models

Article Title: Performance evaluation of a preclinical SPECT system and optimization of imaging protocols for 177Lu-labelled radiopharmaceuticals

Article References: Tosoni, D., Piai, A., Roletto, A., Valtorta, S., Belloli, S., Curnis, F., Chiti, A., Moresco, R. M., & del Vecchio, A. (2026). Performance evaluation of a preclinical SPECT system and optimization of imaging protocols for 177Lu-labelled radiopharmaceuticals. EJNMMI Physics. https://doi.org/10.1186/s40658-026-00950-9

Image Credits: AI Generated

DOI: 10.1186/s40658-026-00950-9

Keywords: SPECT, 177Lu, preclinical imaging, radiopharmaceuticals, theranostics, γ-CUBE, collimators, image quality, mouse cancer model, biodistribution, 99mTc, quantitative accuracy

Cite Scienmag News

Nathaniel Bowman. (October 28, 2026). Preclinical SPECT scanner cuts 177Lu dose needed for sharp mouse tumour imaging. Scienmag. https://scienmag.com/preclinical-spect-scanner-cuts-177lu-dose-needed-for-sharp-mouse-tumour-imaging/

Nathaniel Bowman. "Preclinical SPECT scanner cuts 177Lu dose needed for sharp mouse tumour imaging." Scienmag, 28 October 2026, https://scienmag.com/preclinical-spect-scanner-cuts-177lu-dose-needed-for-sharp-mouse-tumour-imaging/. Accessed 29 October 2026.

Nathaniel Bowman. "Preclinical SPECT scanner cuts 177Lu dose needed for sharp mouse tumour imaging." Scienmag. October 28, 2026. https://scienmag.com/preclinical-spect-scanner-cuts-177lu-dose-needed-for-sharp-mouse-tumour-imaging/

Tags: 177Lu177Lu-labelled peptide dose optimization99mTcbiodistributioncollimator impact on image qualitycollimatorscomparison of 99mTc and 177Lu imagingcontrast-to-noise ratio in preclinical imagingimage qualityminimal radioactive tracer requirementmouse cancer modelmouse cancer model imagingnuclear medicine imaging techniquespreclinical imagingpreclinical SPECT imagingquantitative accuracyradionuclide therapy imagingradiopharmaceuticalssmall animal tumor imagingSPECTtheranostic studies in laboratory animalsTheranosticsγ-CUBEγ-CUBE SPECT system performance
Share26Tweet16
Previous Post

Medicinal Plant Compounds Show Predicted Activity Against Colorectal Cancer Targets

Next Post

Survey Reveals Wide Variation in Anticoagulation After Venous Stenting

Related Posts

Rapid Sequencing Outperforms Routine Tests in Detecting Tuberculosis, Study Finds
Medicine

Rapid Sequencing Outperforms Routine Tests in Detecting Tuberculosis, Study Finds

October 29, 2026
Why Experts Sometimes Trust Their Eyes Too Much: A New Model Separates Two Kinds of Multisensory Learning
Medicine

Why Experts Sometimes Trust Their Eyes Too Much: A New Model Separates Two Kinds of Multisensory Learning

October 29, 2026
Imaging Teamwork Caught Rare Right-Ventricular Thrombi in Inherited Heart Disease
Medicine

Imaging Teamwork Caught Rare Right-Ventricular Thrombi in Inherited Heart Disease

October 29, 2026
Research report: Construction and application of proactive health service for discharged patients based on internet hospital platform
Medicine

Research report: Construction and application of proactive health service for discharged patients based on internet hospital platform

October 29, 2026
Machine Learning Model for Surgical Complications in Older Adults Faces Methodological Critique
Medicine

Machine Learning Model for Surgical Complications in Older Adults Faces Methodological Critique

October 29, 2026
AI matches expert severity ratings in half of hospital adverse event reports
Medicine

AI matches expert severity ratings in half of hospital adverse event reports

October 29, 2026
Next Post
Survey Reveals Wide Variation in Anticoagulation After Venous Stenting

Survey Reveals Wide Variation in Anticoagulation After Venous Stenting

  • Mothers who receive childcare support from maternal grandparents show more optimized

    Mothers who receive childcare support from maternal grandparents show more parental warmth, finds NTU Singapore study

    27656 shares
    Share 11059 Tweet 6912
  • University of Seville Breaks 120-Year-Old Mystery, Revises a Key Einstein Concept

    1061 shares
    Share 424 Tweet 265
  • Bee body mass, pathogens and local climate influence heat tolerance

    682 shares
    Share 273 Tweet 171
  • Researchers record first-ever images and data of a shark experiencing a boat strike

    546 shares
    Share 218 Tweet 137
  • Groundbreaking Clinical Trial Reveals Lubiprostone Enhances Kidney Function

    531 shares
    Share 212 Tweet 133
Science

Embark on a thrilling journey of discovery with Scienmag.com—your ultimate source for cutting-edge breakthroughs. Immerse yourself in a world where curiosity knows no limits and tomorrow’s possibilities become today’s reality!

RECENT NEWS

  • Systematic Review Maps the Genetic Landscape of Epilepsy Across Africa
  • Rapid Sequencing Outperforms Routine Tests in Detecting Tuberculosis, Study Finds
  • Why Experts Sometimes Trust Their Eyes Too Much: A New Model Separates Two Kinds of Multisensory Learning
  • High Seas Treaty Faces Hurdles Sharing Non-Monetary Gains of Marine DNA Data

Categories

  • Agriculture
  • Anthropology
  • Archaeology
  • Athmospheric
  • Biology
  • Biotechnology
  • Blog
  • Bussines
  • Cancer
  • Chemistry
  • Climate
  • Earth Science
  • Editorial Policy
  • Marine
  • Mathematics
  • Medicine
  • Pediatry
  • Policy
  • Psychology & Psychiatry
  • Science Education
  • Science News
  • Social Science
  • Space
  • Technology and Engineering

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 5,151 other subscribers

© 2025 Scienmag - Science Magazine

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • HOME
  • SCIENCE NEWS
  • CONTACT US

© 2025 Scienmag - Science Magazine

Discover more from Science

Subscribe now to keep reading and get access to the full archive.

Continue reading