<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>UHPFRC &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/uhpfrc/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Sat, 10 Oct 2026 12:57:22 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>UHPFRC &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>Tiny PVA Fibers Stop Ultra-Strong Concrete From Exploding in Fires</title>
		<link>https://scienmag.com/tiny-pva-fibers-stop-ultra-strong-concrete-from-exploding-in-fires/</link>
		
		<dc:creator><![CDATA[Denise Maddox]]></dc:creator>
		<pubDate>Sat, 10 Oct 2026 12:57:22 +0000</pubDate>
				<category><![CDATA[Technology and Engineering]]></category>
		<category><![CDATA[advancements in UHPFRC technology]]></category>
		<category><![CDATA[concrete]]></category>
		<category><![CDATA[concrete durability under fire]]></category>
		<category><![CDATA[concrete reinforcement fibers]]></category>
		<category><![CDATA[construction materials]]></category>
		<category><![CDATA[construction safety improvements]]></category>
		<category><![CDATA[crack dispersion in concrete]]></category>
		<category><![CDATA[explosive spalling]]></category>
		<category><![CDATA[explosive spalling in concrete]]></category>
		<category><![CDATA[fiber reinforcement]]></category>
		<category><![CDATA[fire safety]]></category>
		<category><![CDATA[fire safety in structural engineering]]></category>
		<category><![CDATA[fire-resistant concrete materials]]></category>
		<category><![CDATA[high-performance concrete]]></category>
		<category><![CDATA[innovative construction materials]]></category>
		<category><![CDATA[material science in civil engineering]]></category>
		<category><![CDATA[microstructure of high-strength concrete]]></category>
		<category><![CDATA[polyvinyl alcohol fibers]]></category>
		<category><![CDATA[PVA fiber reinforced concrete]]></category>
		<category><![CDATA[residual strength]]></category>
		<category><![CDATA[ring-restraint heating test]]></category>
		<category><![CDATA[thermal stress]]></category>
		<category><![CDATA[UHPFRC]]></category>
		<category><![CDATA[Ultra-High Performance Fiber-Reinforced Concrete]]></category>
		<category><![CDATA[vapor pressure]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=258690</guid>

					<description><![CDATA[Japanese researchers show that polyvinyl alcohol fibers alone can suppress explosive fire spalling in 150-MPa ultra-high-performance concrete through a two-stage mechanism of crack bridging and vapor venting.]]></description>
										<content:encoded><![CDATA[<p>Ultra-high-performance fiber-reinforced concrete, or UHPFRC, is one of the most remarkable construction materials of the modern era. With compressive strengths exceeding 150 megapascals, several times stronger than ordinary structural concrete, it allows engineers to build slimmer bridge decks, longer-lasting infrastructure, and structures that demand far less labor to construct. Its dense microstructure gives it exceptional durability and crack-dispersion properties, and design guidelines for its use have advanced rapidly in Japan, Europe, and the United States. Yet this very density conceals a dangerous weakness: when fire strikes, UHPFRC is far more prone to explosive spalling than normal-strength concrete, a failure mode in which fragments of the surface layer are violently ejected, sometimes with enough force to endanger people and strip away the protective cover over steel reinforcement.</p>
<p>A new study published in Case Studies in Construction Materials by Yuki Kobayashi, Taku Koyama, Keiichi Nakamura, and Mitsuo Ozawa tackles this problem with an elegant twist. Instead of combining steel fibers for strength with polypropylene fibers for fire protection, the team developed a UHPFRC reinforced exclusively with polyvinyl alcohol, or PVA, fibers. Their material achieved a compressive strength of at least 150 megapascals while carrying 1.7 percent by volume of PVA fibers, and their experiments reveal in quantitative detail how these hydrophilic synthetic fibers suppress explosive spalling through a two-stage mechanism that shifts as temperatures climb past the fibers&#8217; melting point.</p>
<p>The physics of spalling in dense concrete is unforgiving. When a fire heats the surface, thermal stress builds at the heated face while water trapped in the pores near the surface turns to vapor. Because UHPFRC has an extremely low permeability, that vapor cannot escape quickly, and pressure builds rapidly in the near-surface pores. At the same time, the material&#8217;s high elastic modulus amplifies thermal stresses generated by steep internal temperature gradients. The combination can crack the surface layer and then blast it away. Once cover concrete is lost, embedded reinforcement heats up faster and the load-bearing cross-section shrinks, so preventing spalling is essential for structural fire safety.</p>
<p>The conventional defense has been to add low doses of polypropylene fibers, which melt at around 170 degrees Celsius and leave behind channels that vent vapor pressure. Steel fibers, meanwhile, boost tensile performance at ambient temperature but are considered ineffective against spalling on their own, and some studies suggest they may even increase spalling risk. PVA fibers occupy a unique middle ground: they are highly hydrophilic and form strong chemical bonds with the cement matrix, which improves crack dispersion and flexural toughness at room temperature while also contributing to fire-spalling mitigation. They are also immune to the corrosion that plagues steel fibers, opening applications in highly corrosive environments or structures requiring non-magnetic properties.</p>
<p>To test their material under conditions closer to real structures, the researchers used the ring-restraint heating test, a method standardized by the Japan Concrete Institute and recommended by RILEM. Rather than heating free-standing cylinders, they cast the UHPFRC into steel rings 300 millimeters in diameter that confine the specimen&#8217;s outer circumference, mimicking the restraint that surrounding structure imposes on a heated member. After preheating a small furnace to roughly 1050 degrees Celsius, they exposed the specimen&#8217;s surface to one-sided heating for 30 minutes, a deliberately severe thermal shock harsher than standard tunnel-fire curves such as ISO 834. Throughout each test they recorded internal temperature, internal water vapor pressure, and the restraint stress acting on the concrete at depths of 5, 10, 25, and 40 millimeters, using strain gauges on the steel ring corrected for thermal expansion and a silicone-oil-filled steel pipe calibrated to separate true vapor pressure from oil-expansion artifacts.</p>
<p>The experimental campaign covered four fiber volume fractions: zero, 0.5, 1.0, and 1.7 percent, with fibers replacing an equivalent volume of sand in a mix with a water-to-binder ratio of just 16 percent. Preliminary testing showed that anything above 1.7 percent destroyed workability, making that the practical ceiling. The PVA fibers themselves were slender, 0.2 millimeters in diameter and 12 millimeters long, with tensile strengths between 1092 and 1716 megapascals. Thermogravimetric analysis showed the fibers begin losing weight near 80 degrees Celsius, melt at 237 degrees Celsius, and thermally decompose between 270 and 460 degrees Celsius, a thermal fingerprint that proved central to interpreting everything that followed.</p>
<p>The results were striking. Spalling depth and spalling volume both decreased steadily as fiber content rose. The fiber-free control developed deep, mortar-shaped defects at the center of the heated surface, and rapid temperature surges repeatedly rippled inward as each spalling event peeled the surface away and shifted the heated front deeper. In the fiber-reinforced specimens, the damage took a different form: layered cracking parallel to the heated surface rather than explosive detachment. Because the surface concrete stayed in place, heat transfer into the interior was limited, and internal temperatures at depth remained markedly lower than in the control. Restraint stress also rose more gradually in fiber-containing specimens, reaching roughly 3 megapascals in the 1.7 percent mix within five minutes of heating, compared with 4.5 megapascals in the fiber-free specimen over the same interval.</p>
<p>One finding defied expectations. Peak internal vapor pressures were higher in the fiber-reinforced specimens, up to 5.7 megapascals at 0.5 percent fiber content, than in the fiber-free control, which peaked at 2.3 megapascals. The researchers attribute this counterintuitive trend to a synergy between the PVA fibers&#8217; high melting point, their strong chemical bonding to the matrix, and the powerful crack-bridging effect of the high fiber dosage. Instead of venting early through cracks, as low-melting, weakly bonded polypropylene fibers allow, the vapor remained trapped because PVA fibers held crack surfaces together until temperatures approached the melting point. The pressure peaked in the range immediately before rapid fiber mass loss, then declined as the fibers melted and vanished, opening dissipation pathways through the voids they left behind.</p>
<p>Complementing the heating tests, residual strength experiments on small cylinders heated slowly to 200, 300, and 400 degrees Celsius mapped how the material degrades. Compressive strength fell to about 55 percent of its unheated value by 200 degrees Celsius, a sharper drop than seen in lower-strength PVA materials or in Eurocode 4 predictions for normal-weight concrete, likely because the dense, ultra-strong matrix generates larger thermal stresses that initiate fine map-like cracks early. The static modulus of elasticity proved even more sensitive, falling to just 18 percent of its initial value at 400 degrees Celsius, reflecting both the loss of fibers and the dehydration and decomposition of the cement hydrates that bind the matrix together.</p>
<p>Finally, the team applied a tensile strain failure model to connect the measurements to a coherent mechanism. When heated concrete expands but is restrained, compressive stress develops in the plane of the surface while tensile strain builds perpendicular to it through the Poisson effect; cracking occurs when that strain exceeds a critical value. Using experimentally derived residual modulus values and restraint stresses, the model reproduced initial spalling progression within about 10 millimeters of the heated surface when the tensile failure strain was set between 50 and 100 microstrain. Notably, for fiber contents of 1.0 percent and above, the model predicted earlier spalling than actually occurred, precisely because it cannot capture the fiber bridging and vapor dissipation that suppress spalling in reality. The authors propose that PVA fibers act in two stages: before melting, crack-bridging holds fractured fragments in place and prevents them scattering; after melting, the void network they leave behind dissipates accumulated vapor pressure. Direct microscopic confirmation of that void network remains future work, but the indirect evidence, from pressure curves that peak near the melting point and then fall, from enhanced air permeability reported in prior studies, and from notched-beam tests showing fibers intact at 200 degrees Celsius but gone at 300, makes a compelling case. If confirmed in full-scale beam tests under standard fire curves, this single-fiber strategy could simplify the design of fire-safe, corrosion-proof ultra-high-performance concrete for the infrastructure of the coming decades.</p>
<p><strong>Subject of Research:</strong> Spalling suppression in ultra-high-performance fiber-reinforced concrete using polyvinyl alcohol fibers</p>
<p><strong>Article Title:</strong> Fire-induced spalling suppression by polyvinyl alcohol fibers in ultra-high-performance fiber-reinforced concrete</p>
<p><strong>Article References:</strong> Kobayashi, Y., Koyama, T., Nakamura, K., &amp; Ozawa, M. (2026). Fire-induced spalling suppression by polyvinyl alcohol fibers in ultra-high-performance fiber-reinforced concrete. <em>Case Studies in Construction Materials, 25</em>, Article e06547. <a href="https://doi.org/10.1016/j.cscm.2026.e06547" rel="noopener noreferrer">https://doi.org/10.1016/j.cscm.2026.e06547</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1016/j.cscm.2026.e06547" rel="noopener noreferrer">10.1016/j.cscm.2026.e06547</a></p>
<p><strong>Keywords:</strong> UHPFRC, polyvinyl alcohol fibers, explosive spalling, fire safety, concrete, vapor pressure, thermal stress, ring-restraint heating test, construction materials, fiber reinforcement, residual strength, high-performance concrete</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">258690</post-id>	</item>
		<item>
		<title>Ultra-Tough Concrete Jacket Could Rescue Corroded Bridges, Simulation Study Shows</title>
		<link>https://scienmag.com/ultra-tough-concrete-jacket-could-rescue-corroded-bridges-simulation-study-shows/</link>
		
		<dc:creator><![CDATA[Denise Maddox]]></dc:creator>
		<pubDate>Sat, 12 Sep 2026 20:14:35 +0000</pubDate>
				<category><![CDATA[Technology and Engineering]]></category>
		<category><![CDATA[advanced materials in civil engineering]]></category>
		<category><![CDATA[bond-slip]]></category>
		<category><![CDATA[bridge safety and maintenance]]></category>
		<category><![CDATA[chloride penetration mitigation]]></category>
		<category><![CDATA[concrete durability]]></category>
		<category><![CDATA[concrete jacket for structural reinforcement]]></category>
		<category><![CDATA[corrosion]]></category>
		<category><![CDATA[corrosion-resistant bridge repair]]></category>
		<category><![CDATA[ductility]]></category>
		<category><![CDATA[durability of offshore structures]]></category>
		<category><![CDATA[finite element analysis]]></category>
		<category><![CDATA[flexural behavior]]></category>
		<category><![CDATA[load-bearing capacity restoration]]></category>
		<category><![CDATA[marine infrastructure]]></category>
		<category><![CDATA[material properties of UHPFRC]]></category>
		<category><![CDATA[numerical simulation of concrete structures]]></category>
		<category><![CDATA[rehabilitation]]></category>
		<category><![CDATA[reinforced concrete]]></category>
		<category><![CDATA[steel reinforcement corrosion]]></category>
		<category><![CDATA[strain hardening]]></category>
		<category><![CDATA[structural retrofit techniques]]></category>
		<category><![CDATA[structural strengthening]]></category>
		<category><![CDATA[UHPFRC]]></category>
		<category><![CDATA[Ultra-High Performance Fiber-Reinforced Concrete]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=198244</guid>

					<description><![CDATA[A new finite element study shows that strain-hardening ultra-high-performance fiber-reinforced concrete jackets can restore up to 273 percent of the flexural capacity of corrosion-damaged reinforced concrete beams while preserving ductility far better than strain-softening variants.]]></description>
										<content:encoded><![CDATA[<p>Reinforced concrete has carried the modern world on its shoulders, from cross-sea bridges and port terminals to offshore wind platforms, but the ocean is quietly eating away at its skeleton. Chloride-laden seawater penetrates even well-made concrete, triggering rust formation inside the steel reinforcement. As the bars corrode, their cross-sections shrink, cracks open, and the bond between steel and concrete decays, sapping the load-bearing capacity, stiffness, and ductility of entire structures. In the worst cases, this hidden deterioration ends not with gradual sagging but with sudden, brittle failure. Now, a detailed numerical study from researchers at institutions affiliated with the University of Macau and collaborators has quantified just how much of that lost performance can be clawed back with a thin jacket of ultra-high-performance fiber-reinforced concrete, or UHPFRC, and revealed that the choice between two subtle variants of the material can mean the difference between a beam that bends gracefully and one that snaps.</p>
<p>UHPFRC is an extraordinary material by any measure. Its ultra-dense matrix dramatically restricts chloride penetration, while embedded steel fibers give it compressive strengths above 150 megapascals and tensile strengths far beyond those of conventional concrete. Earlier experiments have shown that a 60-millimeter UHPFRC layer can more than triple the load capacity of a severely corroded beam, and that U-shaped jackets encasing a beam on three sides can dramatically boost stiffness. Yet a critical complication has gone largely unexamined: not all UHPFRC behaves the same way after it cracks. The French standard NF P18-470 formally separates the family into strain-softening, low strain-hardening, and high strain-hardening grades. Strain-hardening UHPFRC keeps gaining stress after first cracking, spawning networks of fine, distributed micro-cracks and a pseudo-ductile plateau. Strain-softening UHPFRC, though still mechanically superior to ordinary concrete, sheds stress progressively once past its peak, relying on fewer, wider cracks.</p>
<p>Which of these behaviors a given mix displays depends on fiber type, mix proportions, admixtures, and curing conditions, and the consequences for structural rehabilitation are far from academic. Prior experimental campaigns produced apparently contradictory results: one study found that strain-hardening UHPFRC enhanced the ductility of corroded beams, while another reported that strain-softening layers actually reduced it. Because most existing research on this strengthening technique has been experimental, and because numerical modeling of corrosion-induced degradation remains notoriously difficult—with researchers split over how to represent rust expansion, bond loss, and interfacial behavior—the field lacked a reliable computational tool to systematically separate these effects. The new study, published in Case Studies in Construction Materials, was designed to close that gap.</p>
<p>Lead author Zhukai Tang, together with Wai-Meng Quach, Ran Feng, and Zhiyuan Chen, built a nonlinear finite element framework in ABAQUS that tackles the three hardest problems head-on. First, nonlinear spring elements spaced at 50-millimeter intervals connect reinforcement nodes to the surrounding concrete, capturing the bond-slip deterioration that corrosion causes; the springs follow calibrated constitutive laws in which maximum bond stress falls with corrosion ratio according to established models for corroded reinforcement. Second, the interface between the UHPFRC jacket and the substrate concrete is governed by a traction-separation law, whose normal and shear strengths of 19.2 and 5.9 megapascals were extracted directly from slant-shear and double-shear interface tests performed by the team, with damage initiating at a plastic displacement of 0.241 millimeters. Third, the researchers implemented two distinct post-peak tensile constitutive models for UHPFRC, one strain-hardening and one strain-softening, carefully tuned so that both materials shared an identical tensile strength of 11.4 megapascas under the same steel fiber conditions, 15-millimeter-long fibers at 0.2 millimeters diameter and a 2 percent volume fraction. This clever control variable isolates the pure effect of post-cracking behavior on structural response.</p>
<p>The model itself was grounded in real experiments. The team validated it against 24 corroded, UHPFRC-strengthened beams from two published four-point bending campaigns. In the first, six strengthened beams and three unstrengthened controls were exposed to 360 days of wet-dry cycling in artificial seawater, producing 2 to 3 percent corrosion of the bottom reinforcement and stirrups before being retrofitted with 15, 30, or 45 millimeter layers of strain-hardening UHPFRC with a compressive strength of 153.7 megapascals. In the second, 18 beams were corroded by impressed current to controlled ratios of 10 to 23 percent in the bottom bars, then strengthened with strain-softening UHPFRC in bottom-face or U-shape configurations at thicknesses from 20 to 60 millimeters. Across all 24 specimens, the simulated-to-experimental load ratios ranged from 0.90 to 1.08, averaging 0.994 with a standard deviation of just 0.0504, an accuracy rare in corrosion modeling, where stochastic deterioration usually wrecks convergence.</p>
<p>With the model validated, the researchers ran 48 simulations of simply supported beams, sweeping UHPFRC thicknesses from 10 to 60 millimeters in 10-millimeter increments, comparing bottom-face and U-shape jacket configurations, varying corrosion ratios from 5 to 30 percent, and switching between the two tensile constitutive laws. The results are striking. For uncorroded beams, increasing the strain-hardening UHPFRC thickness from 10 to 60 millimeters raised peak load capacity by 8.2 to 79.6 percent with bottom-face strengthening, and by a remarkable 27.8 to 273 percent with U-shape jackets. The strain-softening variant followed similar trends, gaining 4.5 to 59.2 percent and 26.3 to 222.2 percent respectively. In the most extreme case, a 60-millimeter strain-hardening U-shape jacket boosted flexural capacity by 273 percent, yield load by 200.1 percent, and lifted the cracking load from 19.7 kilonewtons to 210.2 kilonewtons—more than a tenfold improvement in the load at which the beam first cracks.</p>
<p>The mechanism behind these gains is partly geometric and partly material. Thicker jackets increase the section depth and moment of inertia, while UHPFRC&#8217;s superior tensile capacity carries stress across cracked zones and unloads the corroded steel. But the fiber-bridging effect proved especially potent for crack control: fibers mechanically anchor micro-cracks, and energy dissipated during fiber pull-out delays the coalescence of macro-cracks. Crack resistance improved even faster with thickness than raw strength did. Failure modes also evolved with the jacket. Bottom-face strengthened beams shifted from tightly concentrated midspan flexural cracking toward a more uniform flexural-shear crack pattern as thickness grew, while U-shape beams tended toward a single dominant flexural crack at peak load, a signature of UHPFRC&#8217;s crack resistance concentrating deformation once fibers began pulling out. Interfacial contact stress analysis showed the highest stresses at the jacket ends, flagging those zones as debonding initiation sites, but the U-shape configuration&#8217;s side arms relieved end-of-span stress concentrations and made debonding significantly less likely than in bottom-face strengthening.</p>
<p>The most consequential finding, however, concerns the two tensile behaviors. Although both materials shared the same tensile strength, the performance gap widened with thickness: peak load differences between strain-hardening and strain-softening versions grew from 5.6 to 25.2 kilonewtons for bottom-face beams, and from 2.0 to 68.5 kilonewtons for U-shape beams, as thickness increased from 10 to 60 millimeters. Yield strength gaps followed the same trajectory. The strain-hardening material&#8217;s extended hardening phase means fibers slip over a longer strain range before pull-out or fracture, sustaining load even as micro-cracks accumulate. Corrosion amplified the contrast further: as corrosion ratios climbed to 30 percent, ductility of strain-softening-strengthened beams degraded much more sharply, because those beams lean heavily on the steel reinforcement for deformation capacity, precisely the component corrosion destroys. Strain-hardening jackets preserved ductility far better. Interestingly, strain-softening beams showed marginally higher initial stiffness, attributed to their stiffer pre-cracking tensile response—small consolation given their deficits elsewhere.</p>
<p>Beyond the simulations, the team distilled a closed-form theoretical model for predicting moment resistance of strengthened beams, accounting for the different stress blocks that strain-hardening and strain-softening UHPFRC produce across the cracked section. Validated against the 48 simulated beams plus test data from four independent experimental studies, the formulation achieved a mean prediction-to-test ratio of 1.012 with a standard deviation of 0.097, giving designers a practical hand-calculation tool for the first time that explicitly distinguishes post-peak material classes. The authors are candid about limitations: corrosion was modeled as uniform rather than pitting, stirrup corrosion was excluded, the flexural-shear mechanism transition was not captured, and the traction-separation law awaits full sensitivity analysis. The model is therefore best suited to moderate corrosion and monotonic loading, with non-uniform corrosion, coupled degradation, and long-term performance flagged for future work.</p>
<p>The practical message for infrastructure owners is clear and actionable. Bottom-face UHPFRC strengthening is the more economical option and still delivers large capacity gains, making it attractive for routine rehabilitation budgets. But when maximum strength, long-term corrosion resistance after retrofit, and preserved ductility are the priorities—as they usually are for critical marine structures—the U-shape jacket in a strain-hardening UHPFRC is the superior choice, and the study shows that specifying the material&#8217;s post-cracking class is not a detail but a decisive engineering parameter. As coastal concrete assets worldwide age into their corrosion-prone decades, tools like this model give engineers a quantitative basis for choosing not just whether to strengthen, but exactly how.</p>
<p><strong>Subject of Research:</strong> Finite element analysis of corroded reinforced concrete beams strengthened with strain-hardening and strain-softening UHPFRC layers</p>
<p><strong>Article Title:</strong> Flexural behavior of corrosion-damaged RC beams strengthened with strain-hardening and strain-softening UHPFRC: Numerical study</p>
<p><strong>Article References:</strong> Tang, Z., Quach, W.-M., Feng, R., &amp; Chen, Z. (2026). Flexural behavior of corrosion-damaged RC beams strengthened with strain-hardening and strain-softening UHPFRC: Numerical study. <em>Case Studies in Construction Materials, 25</em>, Article e06486. <a href="https://doi.org/10.1016/j.cscm.2026.e06486" rel="noopener noreferrer">https://doi.org/10.1016/j.cscm.2026.e06486</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1016/j.cscm.2026.e06486" rel="noopener noreferrer">10.1016/j.cscm.2026.e06486</a></p>
<p><strong>Keywords:</strong> UHPFRC, reinforced concrete, corrosion, finite element analysis, structural strengthening, flexural behavior, marine infrastructure, bond-slip, strain hardening, ductility, concrete durability, rehabilitation</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">198244</post-id>	</item>
	</channel>
</rss>
