<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>tendon-driven actuation &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/tendon-driven-actuation/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Fri, 25 Sep 2026 22:06:23 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.2</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>tendon-driven actuation &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>Robotic Spine That Bends Like a Cheetah&#8217;s Could Supercharge Quadruped Robots</title>
		<link>https://scienmag.com/robotic-spine-that-bends-like-a-cheetahs-could-supercharge-quadruped-robots/</link>
		
		<dc:creator><![CDATA[Denise Maddox]]></dc:creator>
		<pubDate>Fri, 25 Sep 2026 22:06:23 +0000</pubDate>
				<category><![CDATA[Technology and Engineering]]></category>
		<category><![CDATA[animal-inspired robot biomechanics]]></category>
		<category><![CDATA[bio-inspired design]]></category>
		<category><![CDATA[bio-inspired robotic mobility]]></category>
		<category><![CDATA[biomimetic robotic spine]]></category>
		<category><![CDATA[cheetah biomechanics]]></category>
		<category><![CDATA[compression springs]]></category>
		<category><![CDATA[continuum robot degrees of freedom]]></category>
		<category><![CDATA[continuum robots]]></category>
		<category><![CDATA[cross-universal joints]]></category>
		<category><![CDATA[elastic energy storage in robots]]></category>
		<category><![CDATA[flexible robotic spine design]]></category>
		<category><![CDATA[load-bearing]]></category>
		<category><![CDATA[load-bearing robotic structures]]></category>
		<category><![CDATA[locomotion]]></category>
		<category><![CDATA[modular hybrid robotic architecture]]></category>
		<category><![CDATA[Newton-Euler model]]></category>
		<category><![CDATA[quadruped robot agility enhancement]]></category>
		<category><![CDATA[quadruped robot locomotion]]></category>
		<category><![CDATA[quadruped robots]]></category>
		<category><![CDATA[robotic spine]]></category>
		<category><![CDATA[robotic spine flexibility and strength]]></category>
		<category><![CDATA[static modeling]]></category>
		<category><![CDATA[tendon-driven actuation]]></category>
		<category><![CDATA[tendon-driven continuum robots]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=214856</guid>

					<description><![CDATA[A cheetah-inspired tendon-driven robotic spine combining cross-universal joints and compression springs has demonstrated stable bending under a 7.5-kilogram load, far exceeding comparable continuum designs.]]></description>
										<content:encoded><![CDATA[<p>When a cheetah sprints across the savanna, its spine flexes and extends with every stride, storing and releasing elastic energy like a living spring. That remarkable biomechanical trick has long eluded roboticists, whose four-legged machines—from Boston Dynamics&#8217; Spot to MIT&#8217;s Cheetah and ETH Zurich&#8217;s ANYmal—still lumber along on rigid torsos. Now, a team of researchers in China has built a bendable robotic spine inspired by quadruped anatomy that can carry more than three times the load reported for comparable tendon-driven continuum designs, bringing truly agile, animal-like locomotion one step closer.</p>
<p>The new device, described in the journal Results in Engineering, is a tendon-driven continuum robotic spine developed by Jingwei Ke and colleagues. Continuum robots, which deform smoothly along their entire length rather than hinging at discrete joints, offer theoretically infinite degrees of freedom. That makes them ideal mimics of biological spines, but it comes with a notorious weakness: they are typically too floppy to bear significant loads or hold their position accurately when something pushes on them. The team&#8217;s solution is a hybrid architecture that marries rigid and compliant elements into a modular, load-capable structure.</p>
<p>At the heart of the design are cross-universal joints placed between adjacent spacer discs. Unlike a conventional central elastic backbone, such as a flexible nickel-titanium rod, these joints grant two degrees of rotational freedom while actively resisting axial twisting. Torsional rigidity has been a persistent Achilles heel of continuum robots; under asymmetric loading, flexible backbones tend to twist unpredictably, wrecking positioning accuracy. By embedding discrete cross-coupled joints along the central neutral axis, the researchers established a robust torsional load-bearing skeleton that keeps the structure aligned even when forces push unevenly on its sides.</p>
<p>Surrounding this skeleton, pre-compressed coil springs are distributed symmetrically around the spine&#8217;s periphery, directly inspired by the elastic muscle-tendon units of a cheetah&#8217;s back. These passive springs provide stabilizing restoring forces that reduce the peak motor torque needed during load-bearing movements, and they decouple heavy compressive actuation loads from the bending deformation of the joints. That decoupling prevents the structural buckling that plagues standard continuum backbones under heavy loading. Each spring is guided by a sleeve to stop it buckling sideways during compression, and its stiffness can be tuned for different applications—a design flexibility the team says allows engineers to trade compliance against load capacity as needed.</p>
<p>The spine itself measures 230 millimeters long and 160 millimeters in diameter, and bends in two degrees of freedom: sagittal flexion and extension, plus lateral bending—the two dominant posture-adaptation modes seen in legged animals. Three flexible wire ropes, each 3 millimeters thick and arranged 120 degrees apart around the central axis, drive the deformation. The three-tendon layout enables full spatial bending while avoiding the extra weight and complexity of a four-tendon system. In the laboratory prototype, three DJI M3508 motors turn ball screws that precisely lengthen or shorten the tendons, though the authors acknowledge that more compact actuators, such as pulley-based routing or twisted-string mechanisms, would be needed before the spine could ride on an actual walking robot.</p>
<p>Modeling such a structure is fiendishly difficult. Conventional constant-curvature models assume the whole spine bends uniformly, which collapses under real-world loads where segments deform non-uniformly. More sophisticated approaches, like Cosserat rod theory, capture that complexity but require solving computationally expensive boundary value problems. The researchers instead developed a unified static model based on Newton–Euler equations, which treats each spacer disc individually and computes its rotation from local force and moment balance. Crucially, they incorporated a Coulomb friction model describing the interaction between tendons and their guide holes—a factor earlier versions of the work had ignored entirely—with a friction coefficient of 0.3 drawn from reported values for steel cables sliding against polymer sheaths.</p>
<p>The framework also captures the fundamental coupling that makes loaded continuum robots so hard to control: the actuation forces, structural deformation, and external loads all influence one another simultaneously. Because the resulting equations are highly nonlinear and actuation is redundant—three tendons controlling two degrees of freedom—the team solved them numerically, minimizing the sum of tendon tensions subject to static equilibrium constraints. A single solve completes in under one second on an ordinary desktop computer, a computational budget that leaves room for real-time control in a way that Cosserat rod formulations cannot match. Simulations confirmed what the experiments would later show: under load, adjacent segments bend by different amounts, a non-uniform profile the constant-curvature model simply cannot predict.</p>
<p>To choose the right springs, the team swept stiffness values of 10, 20, 30, and 40 newtons per millimeter in simulations with a 7.5-kilogram load. At 10 N/mm the spine deformed excessively, with roughly 10.5 degrees of angular deviation at the tip. At 20 N/mm, the spine achieved an average bending angle of 16.26 degrees across all directions with the best combination of compliance, stability, and solver efficiency, so that value was selected for the physical prototype. Experiments then put the spine through horizontal bending, vertical bending, and a full 360-degree circular trajectory at a 30-millimeter radius, all under a 7.5-kilogram external load while an eight-camera Nokov motion capture system with 0.5-millimeter precision tracked six reflective markers.</p>
<p>The results were striking. The maximum positional error measured was 10.10 millimeters—just 4.40 percent of the spine&#8217;s total length—during horizontal bending, with root-mean-square errors of 4.89, 5.68, and 3.96 millimeters for the circular, horizontal, and vertical trajectories respectively. For context, comparable tendon-driven continuum robots in the literature have been tested at loads ranging from 60 grams to 3.5 kilograms; this design withstood 7.5 kilograms while maintaining stable, controllable bidirectional bending. The authors caution that the comparison is contextual rather than a direct ranking, since the various robots differ in size, materials, and testing protocols, but the margin is nonetheless substantial.</p>
<p>The work remains deliberately scoped to quasi-static behavior: inertial forces, impacts, and vibrations during high-speed running are not yet modeled, and the test loads were applied at the spine&#8217;s tip rather than distributed through a robot&#8217;s torso and limbs as they would be in a complete quadruped. Still, the researchers report that a simplified version of the spine has already been integrated into a quadruped robot prototype, setting the stage for experiments on coordinated spine-limb control, gait performance, and energy efficiency. If those efforts succeed, the rigid-torso robots patrolling disaster zones and inspection sites today may one day move with the supple, spring-loaded grace of the animals that inspired this machine.</p>
<p><strong>Subject of Research:</strong> Bio-inspired tendon-driven continuum robotic spine design for load-bearing quadruped robot applications</p>
<p><strong>Article Title:</strong> Design and evaluation of a bio-inspired tendon-driven continuum robotic spine for quadruped applications</p>
<p><strong>Article References:</strong> Ke, J., Yi, S., Liu, Y., Liu, S., Lei, F., Gu, X., &amp; Guo, Z. (2026). Design and evaluation of a bio-inspired tendon-driven continuum robotic spine for quadruped applications. <em>Results in Engineering, 32</em>, Article 113064. <a href="https://doi.org/10.1016/j.rineng.2026.113064" rel="noopener noreferrer">https://doi.org/10.1016/j.rineng.2026.113064</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1016/j.rineng.2026.113064" rel="noopener noreferrer">10.1016/j.rineng.2026.113064</a></p>
<p><strong>Keywords:</strong> quadruped robots, continuum robots, robotic spine, bio-inspired design, tendon-driven actuation, Newton-Euler model, cross-universal joints, compression springs, load-bearing, cheetah biomechanics, static modeling, locomotion</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">214856</post-id>	</item>
		<item>
		<title>Twisted Wires, Sharper Turns: Rethinking Catheter Routing for ERCP</title>
		<link>https://scienmag.com/twisted-wires-sharper-turns-rethinking-catheter-routing-for-ercp/</link>
		
		<dc:creator><![CDATA[Denise Maddox]]></dc:creator>
		<pubDate>Thu, 24 Sep 2026 23:39:48 +0000</pubDate>
				<category><![CDATA[Technology and Engineering]]></category>
		<category><![CDATA[advancements in minimally invasive biliary procedures]]></category>
		<category><![CDATA[anatomical challenges in ERCP]]></category>
		<category><![CDATA[bile duct cannulation]]></category>
		<category><![CDATA[bile duct cannulation techniques]]></category>
		<category><![CDATA[biomedical engineering]]></category>
		<category><![CDATA[catheter design]]></category>
		<category><![CDATA[challenges in endoscopic retrograde cholangiopancreatography]]></category>
		<category><![CDATA[duodenoscope]]></category>
		<category><![CDATA[endoscopic procedure success factors]]></category>
		<category><![CDATA[endoscopy]]></category>
		<category><![CDATA[ERCP]]></category>
		<category><![CDATA[ERCP catheter navigation]]></category>
		<category><![CDATA[improved endoscope steering mechanisms]]></category>
		<category><![CDATA[innovative catheter routing methods]]></category>
		<category><![CDATA[Japanese research on catheter mechanics]]></category>
		<category><![CDATA[mechanical flaws in steerable catheters]]></category>
		<category><![CDATA[medical device engineering in endoscopy]]></category>
		<category><![CDATA[medical robotics]]></category>
		<category><![CDATA[post-ERCP pancreatitis]]></category>
		<category><![CDATA[Shiga University of Medical Science]]></category>
		<category><![CDATA[steerable catheter]]></category>
		<category><![CDATA[steerable-tip endoscopes]]></category>
		<category><![CDATA[tendon-driven actuation]]></category>
		<category><![CDATA[wire routing]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=213427</guid>

					<description><![CDATA[Researchers in Japan have shown that rerouting a steerable catheter's control wires along non-straight, crossed paths dramatically improves tip bending performance under the constrained conditions of ERCP.]]></description>
										<content:encoded><![CDATA[<p>Every year, hundreds of thousands of patients undergo endoscopic retrograde cholangiopancreatography, or ERCP, a procedure in which physicians thread instruments through the digestive tract to reach the bile and pancreatic ducts. The single most demanding step is selective bile duct cannulation, the delicate act of steering a catheter tip into the papilla of Vater and up into the biliary tree. Success depends on the operator&#8217;s ability to angle the catheter precisely against anatomy that is often hostile: steeply angled orifices, strictures, and surgically altered anatomy that can make a straight instrument nearly useless. Steerable-tip catheters, which bend on demand at the distal end, were developed to solve exactly this problem, yet their real-world performance has been limited by a subtle mechanical flaw that a team of Japanese researchers has now tackled head-on.</p>
<p>The new study, published in Medical &amp; Biological Engineering &amp; Computing by Atsushi Yamada and colleagues at Shiga University of Medical Science, together with Wataru Yonemichi of Zeon Medical Inc., addresses a phenomenon that will be familiar to anyone who has pulled a brake cable on a bicycle: when a wire-driven mechanism is constrained along its length, the actuation forces do not travel cleanly to the tip. Instead, the wires can push and pull against the catheter shaft itself, inducing unintended deformation on the shaft side and bleeding off the transmitted motion. In the constrained environment of a duodenoscope channel, where the catheter shaft is compressed and bent around tight curves, this transmission loss can degrade steerability precisely when the endoscopist needs it most.</p>
<p>Wire-driven steerable catheters work on a simple principle. Two or more control wires run through the length of the instrument to a flexible distal segment; pulling one wire while releasing the other bends the tip toward that side. In a conventional design, the wires are routed in straight, parallel paths from the handle to the bending section. The trouble is that when the operator pulls a wire, the tension does not act only on the distal segment. The wire also presses against the walls of its internal lumens and against the shaft structure, especially when the shaft is constrained inside the endoscope. The result is friction, hysteresis, and a tendency for the shaft itself to buckle or deform, so that handle movement produces less tip bending than expected, and the force required climbs steeply.</p>
<p>Yamada&#8217;s group hypothesized that the wire routing itself was the culprit, and that a non-straight path for the control wires could fundamentally change the mechanics. To test the idea, they built three bidirectional steerable catheter prototypes. The first, designated SC#0, was a conventional design with straight wire routing and served as the baseline. The second, SC#1, used a non-straight but non-crossed routing architecture, in which the wires follow curved paths through the catheter body. The third, SC#2, employed a non-straight, crossed routing scheme, in which the wires cross over one another along their route. The crossed configuration draws on principles established in tendon-driven robotics, where crossing tendons can produce more balanced and efficient actuation of continuum manipulators, and on the team&#8217;s earlier work on flexible ureteroscopes with crossed control wiring.</p>
<p>The evaluation protocol was deliberately rigorous and clinically grounded. Steerability was quantified using incremental wire-pulling tests under two conditions: a straight-shaft condition, in which the catheter was unconstrained, and a loose-shaft condition designed to mimic the constrained reality inside an endoscope. The key outcome measures were the handle displacement and the pulling force required to achieve 85 degrees of distal bending, denoted HD(85) and HPF(85), along with target-angle reachability. An 85-degree bend is a meaningful benchmark because it approximates the acute angulation an endoscopist must generate to redirect the catheter into the bile duct when the anatomy does not cooperate. The team also conducted a mock ERCP study using an actual duodenoscope, testing the catheters in a simulated procedure environment rather than only on a benchtop.</p>
<p>The results were striking. Under the straight-shaft condition, the two non-straight designs reduced the handle displacement needed to reach 85 degrees by 54 to 63 percent, and the required pulling force by 63 to 65 percent, compared with the conventional straight-wired prototype. In other words, the operators could achieve the same bend with roughly a third of the effort and movement. But the more clinically telling result came from the loose-shaft tests, which model the constrained conditions of a real procedure. There, the conventional catheter reached the 85-degree target in only one of five trials, while both non-straight designs achieved it in every single trial. That difference between occasional and reliable performance is exactly the kind of gap that separates a laboratory curiosity from a clinically dependable instrument.</p>
<p>The mock ERCP study reinforced the message. Using an actual duodenoscope, the proposed designs cut handle displacement by 57 to 71 percent and pulling force by 57 to 62 percent relative to the conventional design, and they did so in both bending directions. Bidirectional symmetry matters: a catheter that bends crisply upward but sluggishly downward forces the endoscopist to reposition the entire scope, wasting time and increasing trauma. The crossed and non-crossed non-straight architectures both delivered balanced, efficient steering in either direction, suggesting that the underlying principle, rather than one specific geometric trick, is what drives the improvement.</p>
<p>What is mechanically happening when the wires take a non-straight path? The authors&#8217; analysis, grounded in the broader literature on tendon-driven continuum robots, points to a redistribution of the interaction forces between the wires and the catheter structure. Straight, parallel wires under tension tend to press radially against their lumens and to transmit bending moments along the shaft, particularly when the shaft is bent or compressed. By introducing curvature into the wire paths, and by crossing the wires, the designs alter how tension maps into tip deflection, reducing the parasitic forces that would otherwise deform the shaft and waste the operator&#8217;s input. This is consistent with prior mechanical analyses of friction in single-tendon continuum manipulators and with catheter steering studies in interventional cardiology, where similar transmission losses have long been recognized as a barrier to precise control.</p>
<p>The clinical stakes are considerable. Failed or difficult biliary cannulation is associated with longer procedure times and an elevated risk of post-ERCP pancreatitis, one of the most feared complications of the procedure, which recent systematic reviews of 145 randomized controlled trials place at a persistent and non-trivial incidence. Guidewire-assisted techniques and precut sphincterotomy are established rescue strategies, and steerable-tip catheters have shown promise in case reports for navigating severe strictures, altered surgical anatomy, and steeply angled anastomoses. But if a steerable catheter loses its steering ability when constrained inside the scope, its advantage evaporates. The present findings suggest that non-straight wire routing could make such instruments dependable under exactly those conditions, potentially extending their use from niche rescue devices to routine cannulation tools.</p>
<p>The work is benchtop and mock-procedure research, not yet a clinical trial, and the authors are careful to frame their conclusions accordingly: the findings indicate that non-straight wire-routing architectures can be practically implemented in a bidirectional steerable catheter for ERCP and may improve steerability under ERCP-relevant constraints. Still, the engineering is mature enough that the team has filed Japanese patent applications on the technology, both of which received decisions to grant in 2026, with corresponding U.S. and European applications pending. With a prior version of the group&#8217;s steerable catheter already applied clinically in patients with altered anatomy, the path from prototype to patient-facing device is unusually short. If subsequent clinical studies confirm the benchtop gains, the humble act of rerouting a pair of wires through a curved, crossed path may prove to be one of those rare mechanical insights that quietly reshapes how a high-stakes procedure is performed.</p>
<p><strong>Subject of Research:</strong> Non-straight wire routing to improve the steerability of bidirectional steerable catheters for ERCP bile duct cannulation</p>
<p><strong>Article Title:</strong> Improving practical steerability of a bidirectional steerable catheter for ERCP by non-straight wire routing</p>
<p><strong>Article References:</strong> Improving practical steerability of a bidirectional steerable catheter for ERCP by non-straight wire routing. (n.d.). <a href="https://doi.org/10.1007/s11517-026-03670-5" rel="noopener noreferrer">https://doi.org/10.1007/s11517-026-03670-5</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1007/s11517-026-03670-5" rel="noopener noreferrer">10.1007/s11517-026-03670-5</a></p>
<p><strong>Keywords:</strong> ERCP, steerable catheter, wire routing, bile duct cannulation, endoscopy, medical robotics, tendon-driven actuation, catheter design, post-ERCP pancreatitis, duodenoscope, biomedical engineering, Shiga University of Medical Science</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">213427</post-id>	</item>
	</channel>
</rss>
