<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>sensorless estimation &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/sensorless-estimation/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Tue, 20 Oct 2026 08:36:35 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>sensorless estimation &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>Vision model estimates guidewire contact forces in vessel-phantom images</title>
		<link>https://scienmag.com/vision-model-estimates-guidewire-contact-forces-in-vessel-phantom-images/</link>
		
		<dc:creator><![CDATA[Blake Davidson]]></dc:creator>
		<pubDate>Tue, 20 Oct 2026 08:36:35 +0000</pubDate>
				<category><![CDATA[Technology and Engineering]]></category>
		<category><![CDATA[application of multi-scale feature extraction in medical force prediction]]></category>
		<category><![CDATA[computer vision]]></category>
		<category><![CDATA[end-to-end mapping of planar images to contact forces]]></category>
		<category><![CDATA[error metrics in force estimation models]]></category>
		<category><![CDATA[estimation]]></category>
		<category><![CDATA[force feedback]]></category>
		<category><![CDATA[guidewire contact force]]></category>
		<category><![CDATA[guidewire contact force estimation]]></category>
		<category><![CDATA[image analysis]]></category>
		<category><![CDATA[image-based force prediction using deep learning]]></category>
		<category><![CDATA[Medical Imaging]]></category>
		<category><![CDATA[multi-scale features]]></category>
		<category><![CDATA[non-invasive force measurement in percutaneous coronary intervention]]></category>
		<category><![CDATA[percutaneous coronary intervention]]></category>
		<category><![CDATA[reducing instrumentation complexity in minimally invasive procedures]]></category>
		<category><![CDATA[region masking]]></category>
		<category><![CDATA[region-mask feature extraction in medical imaging]]></category>
		<category><![CDATA[sensor-free force measurement techniques in interventional cardiology]]></category>
		<category><![CDATA[sensorless estimation]]></category>
		<category><![CDATA[vessel phantom]]></category>
		<category><![CDATA[vessel-phantom image analysis for guidewire force assessment]]></category>
		<category><![CDATA[vision-based computational modeling in vessel imaging]]></category>
		<category><![CDATA[visual]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=317173</guid>

					<description><![CDATA[A multi-scale vision model estimated guidewire contact forces from planar images with a mean absolute error of 0.861 g on 343 samples collected from a three-dimensional printed vessel phantom.]]></description>
										<content:encoded><![CDATA[<p>A vision-based computational method estimated guidewire contact forces from conventional planar images without adding sensing hardware. Tested on 343 samples acquired on a three-dimensional printed vessel phantom, the model achieved a mean absolute error (MAE) of 0.861 g and a root mean square error (RMSE) of 1.036 g. An ablation experiment found that adding the region-mask component reduced MAE by 79% relative to the identical architecture without it.</p>
<p>The study addresses contact force between a guidewire and a vessel wall during percutaneous coronary intervention, where force is a key mechanical factor in vessel injury but cannot be measured directly with conventional imaging. Sensor-based methods can measure contact force directly, but they also increase instrumentation complexity and cost. The proposed alternative instead learns an end-to-end mapping from planar images to force values associated with four predefined contact regions, using visual information alone.</p>
<p>Technically, the approach combines multi-scale feature extraction with region-mask mean pooling. The former is incorporated into the model alongside the region-mask operation, while mean pooling summarizes features according to the four designated regions. The system then maps the resulting visual representation to the contact force in each region.</p>
<p>The authors report that the method requires neither additional sensing hardware nor complex physical modeling, distinguishing it from a sensor-based measurement approach. Evaluation was confined to 343 samples acquired on a three-dimensional printed vessel phantom, so the reported performance does not establish accuracy in patients or during live percutaneous coronary intervention. In the ablation comparison, researchers tested the identical architecture without the region mask.</p>
<p>Inclusion of the mask was associated with a 79% reduction in MAE, indicating a substantial contribution from that component within the experimental dataset. The findings support the technical feasibility of vision-based, sensorless contact-force estimation under the tested conditions and suggest a possible route toward force feedback in interventional procedures, but that broader application was not demonstrated.</p>
<p><strong>Subject of Research:</strong> Vision-based estimation of regional guidewire contact forces from planar images</p>
<p><strong>Article Title:</strong> Visual estimation of guidewire contact forces by integrating multi-scale features and region mask</p>
<p><strong>Article References:</strong> Guo, J., Yang, D., Xiao, N., Li, J., Zheng, Q., &amp; Wei, W. (2026). Visual estimation of guidewire contact forces by integrating multi-scale features and region mask. <em>Medical &amp; Biological Engineering &amp; Computing</em>. <a href="https://doi.org/10.1007/s11517-026-03690-1" rel="noopener noreferrer">https://doi.org/10.1007/s11517-026-03690-1</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1007/s11517-026-03690-1" rel="noopener noreferrer">10.1007/s11517-026-03690-1</a></p>
<p><strong>Keywords:</strong> guidewire contact force, computer vision, medical imaging, percutaneous coronary intervention, region masking, sensorless estimation, image analysis, vessel phantom, multi-scale features, force feedback, Visual, estimation</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">317173</post-id>	</item>
	</channel>
</rss>
