<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>refractive index sensing &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/refractive-index-sensing/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Tue, 22 Sep 2026 16:07:36 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.2</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>refractive index sensing &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>Hybrid AI Learns to Read Light Modes in Gold-Coated Fiber Sensors With Near-Perfect Accuracy</title>
		<link>https://scienmag.com/hybrid-ai-learns-to-read-light-modes-in-gold-coated-fiber-sensors-with-near-perfect-accuracy/</link>
		
		<dc:creator><![CDATA[Blake Davidson]]></dc:creator>
		<pubDate>Tue, 22 Sep 2026 16:07:36 +0000</pubDate>
				<category><![CDATA[Technology and Engineering]]></category>
		<category><![CDATA[automated fiber sensor mode identification]]></category>
		<category><![CDATA[biosensor]]></category>
		<category><![CDATA[COMSOL simulation]]></category>
		<category><![CDATA[convolutional neural network]]></category>
		<category><![CDATA[convolutional neural networks for optical mode recognition]]></category>
		<category><![CDATA[EfficientNet]]></category>
		<category><![CDATA[fiber optic biosensors for glucose and blood components]]></category>
		<category><![CDATA[gold-coated photonic crystal fiber biosensor]]></category>
		<category><![CDATA[gradient-boosted decision trees for sensor analysis]]></category>
		<category><![CDATA[light mode classification in fiber sensors]]></category>
		<category><![CDATA[Machine learning]]></category>
		<category><![CDATA[machine learning-based optical mode classification]]></category>
		<category><![CDATA[mode classification]]></category>
		<category><![CDATA[near-perfect accuracy in optical mode detection]]></category>
		<category><![CDATA[photonic crystal fiber]]></category>
		<category><![CDATA[plasmonic sensor design automation]]></category>
		<category><![CDATA[plasmonics]]></category>
		<category><![CDATA[refractive index detection in biological samples]]></category>
		<category><![CDATA[refractive index sensing]]></category>
		<category><![CDATA[support vector machine]]></category>
		<category><![CDATA[support vector machines in fiber optics]]></category>
		<category><![CDATA[surface plasmon resonance]]></category>
		<category><![CDATA[surface plasmon resonance sensing technology]]></category>
		<category><![CDATA[XGBoost]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=206579</guid>

					<description><![CDATA[An Indian research team has combined a gold-coated photonic crystal fiber SPR sensor with a hybrid CNN-SVM-XGBoost framework that classifies optical modes with 99.69 percent accuracy.]]></description>
										<content:encoded><![CDATA[<p>Researchers in India have unveiled a gold-coated photonic crystal fiber biosensor whose operating intelligence comes not from an engineer&#8217;s eye but from an ensemble of machine learning models that classify optical modes with 99.69 percent accuracy. The study, published in Results in Physics, describes a sensor tuned to detect refractive index changes in the biologically important range of 1.37 to 1.40, a window that encompasses glucose solutions, distinct blood components, and certain cancerous cells. By combining a convolutional neural network with support vector machines and gradient-boosted decision trees, the team transformed one of the most tedious steps in plasmonic sensor design, the manual identification of fiber modes, into an automated process that is fast, repeatable, and statistically robust.</p>
<p>Surface plasmon resonance, or SPR, lies at the heart of the device. When p-polarized light strikes a metal-dielectric interface at precisely the right angle and wavelength, it can couple its energy into collective oscillations of free electrons on the metal surface known as surface plasmons. This momentum-matching condition produces a sharp resonant dip in the transmitted spectrum or a pronounced peak in the confinement loss. Because the resonance position is exquisitely sensitive to the refractive index of the surrounding medium, even a minute change in the analyte displaces the resonant wavelength significantly, which is precisely why SPR-based sensors rank among the most sensitive refractive index detection platforms available today.</p>
<p>Conventional SPR excitation relies on prism-based coupling schemes such as the Kretschmann and Otto configurations. These approaches are well understood and have formed the basis of many commercial biosensors, but they demand careful optical alignment, are bulky, and resist miniaturization. Mode mismatch and coupling inefficiencies between the prism apparatus and optical fibers further limit their usefulness in wearable devices, remote sensing, and point-of-care diagnostics. Photonic crystal fibers offer a compelling alternative. These microstructured optical fibers surround their core with a periodic lattice of air holes running along the fiber length, and by engineering the size, shape, and placement of those holes, designers can force the core-guided light to overlap strongly with the external environment, marrying the sensitivity of SPR with the compactness and long-haul compatibility of fiber optics.</p>
<p>The team&#8217;s proposed architecture, modeled with the finite element method in COMSOL Multiphysics 6.0, uses a fused silica background with two rings of air holes, ten holes of 0.8 micrometer diameter and twenty-four holes of 1.6 micrometer diameter, plus a central hole, arranged to maximize coupling from the core mode into the plasmonic mode. Two channels of three enlarged outer air holes are deliberately opened to let light penetrate from the core toward the plasmonic region. A symmetrical cylindrical layer of gold, thirty nanometers thick, is coated externally around the core, followed by a one-micrometer analyte layer thick enough to fully contain the decay of the plasmonic field. Fused silica was chosen for its low optical loss, mechanical strength, and well-characterized dispersion, modeled through the Sellmeier equation, while the optical constants of gold were captured with a Drude-Lorentz dispersion model that accounts for both free-electron response and interband transitions.</p>
<p>The physics behind the sensor&#8217;s operation is elegantly visible in the simulation data. For an analyte of refractive index 1.38, the real parts of the effective refractive indices of the core-guided fundamental mode and the surface plasmon polariton mode intersect at a resonance wavelength of 0.705 micrometers under y-polarization, exactly where the confinement loss peaks. The narrow full-width-half-maximum of the loss spectrum signals strong light-matter interaction and minimal spectral broadening. As the analyte index rises from 1.37 to 1.40, the resonance wavelength shifts monotonically toward longer values, a red shift caused by the increased permittivity at the gold-analyte interface that strengthens plasmonic confinement. Wavelength sensitivity reaches 13,500 nanometers per refractive index unit at an analyte index of 1.39, with a corresponding resolution of 7.41 x 10^-6 RIU, figures that outperform comparable gold-coated and arc-shaped PCF-SPR sensors reported in recent literature.</p>
<p>Yet the design&#8217;s most distinctive contribution is not the fiber geometry but the artificial intelligence layered on top of it. Traditional sensor development leans on physics-based simulations that are computationally exhaustive, and identifying which computed mode is the fundamental core mode and which is a surface plasmon polariton has long been a subjective, error-prone judgment call, especially near resonance where the modes hybridize. Earlier machine learning efforts in optical sensing were largely regression-based, predicting resonance shifts without exploiting the rich spatial information embedded in electromagnetic field distributions. The authors&#8217; hybrid framework closes that gap by treating each mode&#8217;s field-intensity image as data to be learned from.</p>
<p>The pipeline begins with EfficientNet-B0, a computationally lean pretrained convolutional neural network whose MBConv blocks and Swish activations extract local spatial patterns such as hot-spot localization, nodal lines, symmetry features, and mode leakage signatures. Its dense layers compress each 224 by 224 pixel field image into a compact 256-dimensional feature embedding. Transfer learning was applied by freezing most of the pretrained layers, reducing trainable parameters and suppressing overfitting. These deep features then feed three complementary classifiers: a support vector machine with a radial basis function kernel, an XGBoost ensemble of fifty trees with depth three, and a logistic regression meta-learner that fuses their outputs. Logistic regression was selected for its low computational cost, strong generalization on limited datasets, and interpretability, combining the CNN, SVM, and XGBoost predictions in a stable and traceable manner.</p>
<p>Training data comprised 323 simulated modal field distribution images spanning the fundamental core mode, surface plasmon polariton modes, and higher-order SPP coupling modes, generated across wavelengths from 0.60 to 1.00 micrometers in steps of 0.005 micrometers under both x- and y-polarizations for an analyte index of 1.38. Stratified five-fold cross-validation, dropout regularization, adaptive learning-rate scheduling with ReduceLROnPlateau, early stopping, and training-fold-only data balancing all guarded against overfitting and leakage. The payoff was dramatic: the standalone CNN managed only 76.36 percent accuracy with a sprawling standard deviation of 31.29 percent, while the full hybrid stack achieved 99.69 percent plus or minus 0.62 percent, with precision and specificity of a perfect 100 percent, recall of 99.63 percent, an F1-score of 99.81 percent, and a Matthews correlation coefficient of 98.97 percent. On the test set, the model correctly identified 268 of 269 SPP modes and all 54 core modes, committing just a single false assignment across the entire classification task.</p>
<p>The team pushed validation further with 1,000-iteration bootstrap resampling at a 95 percent confidence level, confirming that accuracy clustered between 0.9907 and 1.0000 and that the Matthews correlation coefficient remained above 0.9630, evidence that the model&#8217;s performance is stable rather than a statistical fluke. Receiver operating characteristic analysis yielded an area under the curve of 0.9999, and t-distributed stochastic neighbor embedding of the learned feature space produced well-separated clusters of fundamental and SPP modes with a Silhouette score of 0.3147, a Davies-Bouldin index of 0.6301, and a Calinski-Harabasz index of 159.5034. SHAP explainability analysis revealed that the real part of the effective index and the mode index dominated decisions for core modes, while the imaginary part of the effective index carried the most weight for SPP identification, confirming that the network&#8217;s predictions rest on physically meaningful quantities rather than artifacts.</p>
<p>The authors acknowledge that fabrication remains demanding. Forming precise, uniform air holes of the specified diameters is critical, because even small deviations can disturb the phase-matching condition, and maintaining hole circularity during fiber drawing is difficult due to thermal deformation. Depositing a uniform 30-nanometer gold film at microscale dimensions is challenging, since surface roughness increases plasmonic damping, and controlled infiltration of the thin analyte layer affects long-term stability. Fortunately, mature thin-film techniques including thermal evaporation, magnetron sputtering, chemical vapor deposition, atomic layer deposition, and electroless plating can all be applied, and experimentally demonstrated externally coated micro-channel SPR-PCF sensors already exist in the literature, suggesting the design is within practical reach. While the current study is computational, focusing on mode classification rather than real-time spectral analysis from an optical spectrum analyzer, the researchers argue that the hybrid machine learning framework points toward intelligent sensing systems capable of autonomously analyzing spectral data, cutting simulation costs, and accelerating the journey of plasmonic biosensors from laboratory prototype to clinical and environmental deployment.</p>
<p><strong>Subject of Research:</strong> Hybrid machine learning classification of optical modes in a gold-coated SPR-driven photonic crystal fiber biosensor</p>
<p><strong>Article Title:</strong> Hybrid machine learning approach for mode classification of SPR driven photonic crystal fiber sensor</p>
<p><strong>Article References:</strong> Harsh, D. R., Khatri, N., &amp; Awasthi, S. K. (2026). Hybrid machine learning approach for mode classification of SPR driven photonic crystal fiber sensor. <em>Results in Physics, 88</em>, Article 108746. <a href="https://doi.org/10.1016/j.rinp.2026.108746" rel="noopener noreferrer">https://doi.org/10.1016/j.rinp.2026.108746</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1016/j.rinp.2026.108746" rel="noopener noreferrer">10.1016/j.rinp.2026.108746</a></p>
<p><strong>Keywords:</strong> photonic crystal fiber, surface plasmon resonance, machine learning, convolutional neural network, XGBoost, support vector machine, biosensor, refractive index sensing, mode classification, EfficientNet, plasmonics, COMSOL simulation</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">206579</post-id>	</item>
		<item>
		<title>AI-Inspired Algorithms Sharpen a Copper-Based Optical Sensor for Arsenic-Tainted Groundwater</title>
		<link>https://scienmag.com/ai-inspired-algorithms-sharpen-a-copper-based-optical-sensor-for-arsenic-tainted-groundwater/</link>
		
		<dc:creator><![CDATA[Denise Maddox]]></dc:creator>
		<pubDate>Sat, 12 Sep 2026 22:40:40 +0000</pubDate>
				<category><![CDATA[Technology and Engineering]]></category>
		<category><![CDATA[advancements in optical sensor sensitivity]]></category>
		<category><![CDATA[AI-driven optical sensor design]]></category>
		<category><![CDATA[AI-enhanced environmental analytical tools]]></category>
		<category><![CDATA[arsenic detection]]></category>
		<category><![CDATA[Bangladesh]]></category>
		<category><![CDATA[challenges in arsenic monitoring in rural Bangladesh]]></category>
		<category><![CDATA[computational modeling for sensor development]]></category>
		<category><![CDATA[copper plasmonics]]></category>
		<category><![CDATA[copper-based nanomaterials for arsenic sensing]]></category>
		<category><![CDATA[differential evolution]]></category>
		<category><![CDATA[environmental health impacts of arsenic contamination]]></category>
		<category><![CDATA[genetic algorithm]]></category>
		<category><![CDATA[groundwater]]></category>
		<category><![CDATA[groundwater arsenic detection]]></category>
		<category><![CDATA[Kretschmann configuration]]></category>
		<category><![CDATA[label-free arsenic detection methods]]></category>
		<category><![CDATA[low-cost solutions for water quality assessment]]></category>
		<category><![CDATA[machine learning optimization of environmental sensors]]></category>
		<category><![CDATA[metaheuristic optimization]]></category>
		<category><![CDATA[particle swarm optimization]]></category>
		<category><![CDATA[portable groundwater testing technologies]]></category>
		<category><![CDATA[refractive index sensing]]></category>
		<category><![CDATA[surface plasmon resonance]]></category>
		<category><![CDATA[water quality monitoring]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=199360</guid>

					<description><![CDATA[Researchers have combined transfer-matrix modeling, finite-element validation, and a comparative metaheuristic optimization framework to design a low-cost copper-based surface plasmon resonance sensor aimed at arsenic monitoring in Bangladesh's contaminated groundwater.]]></description>
										<content:encoded><![CDATA[<p>Arsenic in the groundwater of Bangladesh remains one of the world&#8217;s most severe environmental health crises, with naturally mobilized arsenic exceeding guideline values across large parts of the Bengal Basin. Millions of people draw their drinking water from shallow tube wells, and chronic exposure to inorganic arsenic has been linked to dermatological, cardiovascular, neurological, and carcinogenic effects even at concentrations close to regulatory thresholds. National survey data show extensive regions where concentrations surpass the World Health Organization guideline of 10 micrograms per liter. Against this backdrop, researchers have now designed and computationally optimized a compact optical sensor that could bring sensitive, label-free arsenic monitoring closer to the communities that need it most, without the centralized laboratory infrastructure that conventional testing demands.</p>
<p>Traditional arsenic quantification relies on techniques such as atomic absorption spectrometry, inductively coupled plasma mass spectrometry, and ion chromatography. These methods deliver excellent sensitivity and speciation capability, but they require sophisticated instrumentation and trained personnel, which limits routine, high-frequency surveillance across dispersed rural wells. Portable electrochemical and colorimetric assays have been deployed in national screening programs, yet they often demand chemical pre-treatment, suffer matrix-dependent interference, or lack the quantitative precision needed for long-term monitoring and remediation validation. Optical approaches such as fluorometric and colorimetric platforms respond rapidly and can be portable, but many depend on specialized reagents, complex surface functionalization, or indirect detection mechanisms that can undermine long-term stability and selectivity in the field.</p>
<p>The new study, published in Results in Optics, turns to surface plasmon resonance, a label-free optical technique with real-time response and exceptional sensitivity to refractive-index variations at a metal-dielectric interface. In the classic Kretschmann configuration, a p-polarized beam passing through a high-index prism excites a surface plasmon polariton at a thin metallic layer, and any change in the adjacent aqueous refractive index is translated into a measurable shift of the resonance angle. Surface plasmon resonance has long been applied to chemical and biomedical sensing, including prior arsenic quantification, but achieving simultaneously high sensitivity, narrow resonance linewidth, and a strong quality factor remains a major challenge when the refractive-index perturbations associated with contamination are small.</p>
<p>The research team, led by Khandoker Tauhid Imam with Masiath Ibna Jamil and Md. Aminur Rahman, addressed three gaps that persist in the literature. Most optimized multilayer plasmonic sensors target biomedical or generic water-quality scenarios rather than groundwater arsenic specifically. Comparative studies evaluating multiple optimization algorithms on the same multilayer platform are scarce, limiting insight into how different strategies trade off sensitivity, resonance sharpness, and fabrication feasibility. And few studies have explored low-cost copper-based architectures that balance a high quality factor, narrow linewidth, and manufacturability. To fill these gaps, the team designed an S-FPL53 prism/MgF2/Cu/Ni/ZnSe multilayer stack that combines dielectric-assisted coupling with bimetallic plasmonic confinement, and subjected it to a rigorous computational design pipeline.</p>
<p>The theoretical backbone of the work is the transfer matrix method, which provides an exact closed-form solution for wave propagation in stratified planar media and can rapidly evaluate reflection spectra for thousands of candidate thickness combinations. In the Kretschmann geometry, resonance occurs when the in-plane component of the incident wavevector matches the surface plasmon polariton wavevector at the metal-dielectric boundary. Sweeping the incidence angle at a fixed wavelength of 632.8 nanometers identifies the resonance minimum from which the resonance angle and full width at half maximum are extracted, feeding into standard performance metrics: angular sensitivity, detection accuracy, quality factor, figure of merit, and a refractive-index limit of detection. To guard against numerical artifacts, the team independently cross-validated all resonance characteristics with finite-element simulations in COMSOL Multiphysics, which solve the full boundary-value problem of Maxwell&#8217;s equations without assuming planar layering. The two methods agreed closely on resonance angles, linewidths, and field distributions, and the field maps revealed strong confinement at the Cu/Ni-ZnSe boundary with an evanescent penetration depth of roughly 209 nanometers into the analyte, sufficient to probe the bulk aqueous medium.</p>
<p>A critical modeling step involved estimating the refractive index of arsenic-doped water. Experimental calibration data from a photonic-crystal-fiber SPR study supplied refractive indices for arsenic concentrations between 0.1 and 0.5 percent, and the team extrapolated to 1.0 percent using linear regression, quadratic regression, and a rate-based method. The quadratic model proved most reliable, achieving a coefficient of determination of 0.9975 and a root mean square error of 4.81 by 10 to the minus 6, predicting a refractive index of about 1.3474 at 1.0 percent. Leave-one-out cross-validation and a 95 percent prediction interval confirmed the stability of this extrapolation, although the authors honestly note that the five-point dataset remains limited and that direct measurements at higher concentrations are a priority for future work. They are equally transparent that the laboratory calibration concentrations are roughly five orders of magnitude higher than the parts-per-billion levels of the WHO guideline, so the study should be read as a demonstration of refractive-index sensitivity and optimization methodology rather than a direct simulation of field-realistic arsenic levels.</p>
<p>Within the specified refractive-index window from 1.330 for pure water to 1.3474, the manually tuned baseline sensor performed strongly. The resonance dip sat at 79.78 degrees for pure water and shifted progressively to 85.70, 85.86, and 86.34 degrees as arsenic-derived refractive indices rose, yielding sensitivities of 361.42, 365.17, and 377.01 degrees per refractive-index unit with linewidths of only about 2.4 to 2.6 degrees. The SNR-limited refractive-index detection limit remained near 1.1 by 10 to the minus 6 RIU across all concentrations. Comparative screening showed that the low-index Ohara S-FPL53 prism nearly tripled the sensitivity of a conventional BK7 prism, that copper outperformed silver in figure of merit by more than an order of magnitude while matching its sensitivity, and that thickness sweeps identified roughly 50-nanometer copper and 2-nanometer ZnSe as the sweet spots balancing sensitivity against resonance sharpness. Against published aqueous SPR sensors operating near the water refractive-index region, the design&#8217;s 377 degrees per RIU was the highest angular sensitivity reported among the compared structures.</p>
<p>The centerpiece of the study, however, is a head-to-head comparison of three metaheuristic algorithms, Differential Evolution, Particle Swarm Optimization, and a Genetic Algorithm, all run with identical population sizes of 30, identical generation counts of 40, identical search bounds, and the same transfer-matrix fitness evaluation. Differential Evolution and Particle Swarm Optimization converged to nearly identical thickness configurations, with copper near 59.3 nanometers, nickel at 1 nanometer, and ZnSe at 2 nanometers, and delivered the sharpest resonances: quality factors up to 67.64, figures of merit approaching 202 per RIU, and linewidths narrowed to about 1.22 degrees. The Genetic Algorithm instead pushed angular sensitivity beyond 308 degrees per RIU at the cost of broader dips and lower quality factors. Across 25 independent runs, DE and PSO converged rapidly with minimal variability, standard deviations of 0.0051 and 0.3019 respectively, while GA varied far more, with a standard deviation of 6.0231. A multi-objective Differential Evolution run further improved average figure of merit and quality factor by 51.57 percent and 169.45 percent at the expense of a 33.89 percent sensitivity reduction, giving designers a tunable trade-off between spectral resolution and raw sensitivity.</p>
<p>Fabrication feasibility and robustness were examined in detail. Every layer can be produced with mature thin-film techniques: thermal or electron-beam evaporation and atomic layer deposition for the magnesium fluoride spacer, magnetron sputtering for copper, RF sputtering for the protective nickel cap, and evaporation, sputtering, or chemical vapor deposition for ZnSe. A tolerance analysis with plus-or-minus 5 and 10 percent thickness perturbations showed that the magnesium fluoride layer is essentially immune to error, that copper thickness most strongly governs resonance sharpness and quality factor, and that the ultrathin nickel and ZnSe films are most critical per nanometer for preserving sensitivity, underscoring the value of atomic-scale deposition control for the thinner layers. Even under worst-case simultaneous minus-10 percent deviations the sensor retained a sensitivity above 311 degrees per RIU, while positive deviations pushed performance as high as 443.79 degrees per RIU.</p>
<p>The authors are careful about the road to deployment. Because the structure transduces bulk refractive index rather than binding arsenic specifically, selective quantification in real groundwater, which contains iron, manganese, bicarbonate, dissolved organic matter, and other constituents, will require complementary surface functionalization, reference-channel compensation, or multivariate calibration. Temperature fluctuations alone shift the refractive index of water by roughly 1 by 10 to the minus 4 RIU per degree Celsius, comparable to the signals of low arsenic concentrations, so field instruments will need thermal compensation, vibration-stable angular interrogation or a move toward fixed-angle schemes, and periodic recalibration against arsenic-free references, ideally on low-power solar-supplemented electronics suited to rural Bangladesh. Even so, the combination of a low-cost copper plasmonic layer rather than gold, sharp optimized resonances, demonstrated fabrication tolerance, and a transparent, reproducible optimization framework makes this multilayer design a compelling transduction platform. With appropriate arsenic-selective chemistry layered on top, the same architecture could ultimately serve decentralized tube-well screening, and the authors plan experimental fabrication, stability testing, and validation with real groundwater samples from arsenic-affected regions as the next steps.</p>
<p><strong>Subject of Research:</strong> Metaheuristic optimization of a multilayer surface plasmon resonance sensor for arsenic monitoring in groundwater in Bangladesh</p>
<p><strong>Article Title:</strong> Comparative metaheuristic optimization of a multilayer SPR sensor for arsenic monitoring in groundwater in Bangladesh</p>
<p><strong>Article References:</strong> Imam, K. T., Jamil, M. I., &amp; Rahman, M. A. (2026). Comparative metaheuristic optimization of a multilayer SPR sensor for arsenic monitoring in groundwater in Bangladesh. <em>Results in Optics, 25</em>, Article 101134. <a href="https://doi.org/10.1016/j.rio.2026.101134" rel="noopener noreferrer">https://doi.org/10.1016/j.rio.2026.101134</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1016/j.rio.2026.101134" rel="noopener noreferrer">10.1016/j.rio.2026.101134</a></p>
<p><strong>Keywords:</strong> surface plasmon resonance, arsenic detection, groundwater, Bangladesh, metaheuristic optimization, Differential Evolution, Particle Swarm Optimization, Genetic Algorithm, copper plasmonics, refractive index sensing, Kretschmann configuration, water quality monitoring</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">199360</post-id>	</item>
		<item>
		<title>Hybrid graphene–MXene–WS₂ terahertz metasurface detects chikungunya virus via machine learning</title>
		<link>https://scienmag.com/hybrid-graphene-mxene-ws%e2%82%82-terahertz-metasurface-detects-chikungunya-virus-via-machine-learning/</link>
		
		<dc:creator><![CDATA[Neil Sanderson]]></dc:creator>
		<pubDate>Fri, 11 Sep 2026 10:38:52 +0000</pubDate>
				<category><![CDATA[Technology and Engineering]]></category>
		<category><![CDATA[advanced materials for virus detection]]></category>
		<category><![CDATA[chikungunya virus detection]]></category>
		<category><![CDATA[computational biosensor design]]></category>
		<category><![CDATA[computational biosensor engineering]]></category>
		<category><![CDATA[electromagnetic sensor design]]></category>
		<category><![CDATA[high sensitivity biosensors]]></category>
		<category><![CDATA[high sensitivity terahertz sensors]]></category>
		<category><![CDATA[hybrid graphene MXene WS₂]]></category>
		<category><![CDATA[hybrid graphene–MXene–WS₂ metasurface]]></category>
		<category><![CDATA[machine learning in biosensing]]></category>
		<category><![CDATA[multilayer architecture]]></category>
		<category><![CDATA[multilayer nanomaterials]]></category>
		<category><![CDATA[nanomaterial-based sensors]]></category>
		<category><![CDATA[point-of-care virus diagnostics]]></category>
		<category><![CDATA[public health diagnostics]]></category>
		<category><![CDATA[refractive index sensing]]></category>
		<category><![CDATA[terahertz biosensor]]></category>
		<category><![CDATA[terahertz metasurface biosensor]]></category>
		<category><![CDATA[virus diagnosis in field settings]]></category>
		<category><![CDATA[XGBoost surrogate model]]></category>
		<guid isPermaLink="false">https://scienmag.com/hybrid-graphene-mxene-ws%e2%82%82-terahertz-metasurface-detects-chikungunya-virus-via-machine-learning/</guid>

					<description><![CDATA[Scientists have unveiled a computational design for a terahertz metasurface biosensor that combines five distinct materials—graphene, MXene, tungsten disulfide, gold, and copper—into a single multilayer architecture capable of detecting refractive-index changes associated with chikungunya virus infection. The study, published in Results in Optics by G. Arunachalam, A.R. Kalaiarasi, Giri.G. Hallur, and V. Parthasarathy, reports a [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Scientists have unveiled a computational design for a terahertz metasurface biosensor that combines five distinct materials—graphene, MXene, tungsten disulfide, gold, and copper—into a single multilayer architecture capable of detecting refractive-index changes associated with chikungunya virus infection. The study, published in Results in Optics by G. Arunachalam, A.R. Kalaiarasi, Giri.G. Hallur, and V. Parthasarathy, reports a numerically predicted sensitivity of 907 GHz per refractive-index unit, among the highest values reported for hybrid-material terahertz biosensors, and couples the electromagnetic design to an XGBoost machine-learning surrogate model that predicts sensor behavior with accuracies exceeding 99.8 percent.</p>
<p>Chikungunya virus is an enveloped, positive-sense single-stranded RNA alphavirus transmitted primarily by Aedes aegypti and Aedes albopictus mosquitoes. While mortality remains low, generally below 0.1 percent, the broader public health burden arises from severe polyarthralgia that can persist for months or even years in a substantial fraction of patients across tropical and subtropical regions. With no approved antiviral therapy or licensed vaccine currently available, diagnostic accuracy sits at the center of clinical management and transmission control. Yet existing diagnostic tools face significant practical constraints, particularly in point-of-care and field settings.</p>
<p>Serological methods such as enzyme-linked immunosorbent assay suffer from cross-reactivity with related alphaviruses, including Ross River and O&#8217;nyong-nyong viruses, reducing diagnostic specificity. Real-time reverse transcription polymerase chain reaction offers high sensitivity during the acute phase but depends on laboratory infrastructure, trained personnel, and controlled sample handling. Virus isolation in cell culture provides confirmatory results but requires biosafety level-3 facilities and extended processing time. These limitations have motivated the search for rapid, label-free sensing approaches capable of operating at clinically relevant concentrations in decentralized environments.</p>
<p>The new work turns to the terahertz band, spanning roughly 0.1 to 10 THz, which lies between microwave and infrared regions of the electromagnetic spectrum. Terahertz radiation is non-ionising, with photon energies in the millielectronvolt range, allowing interaction with biological samples without causing ionising damage. Crucially, terahertz waves couple to low-frequency vibrational and rotational modes of biomolecules such as proteins, nucleic acids, and polysaccharides, producing measurable spectral features that support label-free detection. Because biological media including blood plasma and viral suspensions exhibit refractive-index variations in this domain, differences on the order of 0.01 to 0.02 refractive-index units can shift resonance frequency and field distribution when coupled to resonant sensing structures.</p>
<p>The proposed sensor is built around a periodically repeated square unit cell containing two identical square resonators, 2000 nanometers on a side, coated with tungsten disulfide—a two-dimensional transition metal dichalcogenide with strong light–matter interaction, high carrier mobility, and excellent dielectric confinement. This layer localizes the electric field in the sensing region and increases the interaction volume between the resonant field and the surrounding analyte. A pair of concentric circular rings, 3200 and 3800 nanometers in diameter and functionalized with MXene, surrounds the resonators, enhancing electromagnetic coupling, promoting efficient charge transport, and strengthening plasmonic interactions between resonator elements. An outer gold ring, 6000 nanometers in diameter, serves as the main plasmonic resonator supporting strong localized surface plasmon resonances with low optical loss. The entire multi-resonant assembly is embedded within a monolayer graphene sheet measuring 14,000 by 14,000 nanometers, which acts as a broadband absorber and a high-mobility charge transport medium whose electrically tunable chemical potential allows dynamic, active control of the resonance characteristics. Copper elements woven into the architecture provide supplementary conductive pathways that reinforce current distribution and coupling among the hybrid resonators. The structure rests on a silicon dioxide substrate, chosen for its low dielectric loss and mechanical robustness, which preserves the resonance quality factor.</p>
<p>The authors stress that the multilayer design is compatible with established microfabrication techniques. Fabrication would begin with a cleaned silicon dioxide substrate, followed by polymer-assisted transfer of monolayer graphene and thermal annealing. Gold and copper resonators can be deposited through electron-beam evaporation or magnetron sputtering with lift-off patterning, MXene rings through solution-based deposition, and the tungsten disulfide layer through chemical vapor deposition or thin-film transfer. With a unit-cell dimension of approximately 14 micrometers, the required feature sizes fall comfortably within conventional photolithography capabilities, and because fabrication imperfections remain far smaller than the operating terahertz wavelength, moderate tolerances are expected to have only limited influence on the electromagnetic response. For biosensing, the graphene surface could subsequently be functionalized with chikungunya-specific antibodies or aptamers using EDC/NHS or pyrene-based linker chemistries.</p>
<p>The electromagnetic modeling, performed in COMSOL Multiphysics, reveals a pronounced resonance at 0.355 THz, where electric-field simulations show the strongest and most spatially extensive enhancement. Varying the graphene chemical potential from 0.1 to 0.9 electronvolts produced dramatic modulation of the transmission contrast, which increased roughly 36-fold at the highest bias, from less than one percentage point to more than 27 percentage points, while peak transmission remained essentially unchanged above 98.6 percent. This asymmetric response—stable maxima paired with strongly modulated minima—arises because increasing chemical potential enhances graphene&#8217;s intraband conductivity, deepening resonant absorption through stronger light–matter interaction. The sensor also demonstrated remarkable angular robustness, maintaining peak transmittance above 97.8 percent across incident angles from 0 to 80 degrees, an important tolerance for realistic deployment where normal incidence cannot always be guaranteed.</p>
<p>Geometric optimization identified an outer circular resonator radius of 2500 nanometers and a square resonator side length of 2500 nanometers as the dimensions that maximize resonance strength, driving minimum transmittance down to approximately 65 to 67 percent and signifying optimal electromagnetic confinement within the active sensing region. When evaluated across refractive indices from 1.33 to 1.39, a range encompassing reported values for healthy plasma (approximately 1.35 RIU), healthy platelets (1.39 RIU), chikungunya-infected plasma (1.33 RIU), and infected platelets (1.38 RIU), the optimized configuration achieved a maximum sensitivity of 907 GHz/RIU, a figure of merit of 18.519 RIU⁻¹, a minimum detection limit of 0.061 RIU, a sensor resolution of 55.178, and a refractive-index resolution of 0.001 RIU. In comparative benchmarks against recently reported graphene- and hybrid-material-based terahertz biosensors—including graphene/copper/aluminum, graphene/silicon dioxide, MXene–graphene–black phosphorus, and graphene-integrated copper–silver designs—the proposed architecture&#8217;s sensitivity exceeded most published values, reflecting the synergistic field confinement produced by the five-material stack.</p>
<p>The machine-learning component addresses one of the central bottlenecks in metasurface development: the computational cost of repeated full-wave finite-element simulations during structural optimization. The team trained an XGBoost regressor, an ensemble method based on gradient-boosted decision trees, on simulation data covering incidence-angle variation and circular-ring dimension variation, using stratified sampling with 80 percent of data for training and 20 percent held out for independent testing, alongside five-fold cross-validation and grid-search hyperparameter optimization. The model captured more than 99.7 percent of response variance on unseen data, with mean absolute percentage errors below 0.162 percent and prediction accuracies from 99.838 to 99.959 percent. Acting as a computational surrogate, the trained model enables rapid interpolation across the design space without sacrificing the fidelity of the underlying electromagnetic model.</p>
<p>The authors are careful to frame the work as a computational proof-of-concept rather than an experimentally validated diagnostic. The sensor detects changes in the local dielectric environment surrounding the resonators, not viral particles or nucleic acids directly, and refractive-index sensing alone cannot intrinsically distinguish chikungunya from other viruses with similar dielectric properties. Analytical specificity in practice will depend on surface biofunctionalization with chikungunya-specific recognition molecules immobilized on the graphene or gold sensing surface. Future work will focus on device fabrication, biofunctionalization, calibration with reference refractive-index standards, experimental validation with clinically relevant plasma and platelet samples, and systematic evaluation of selectivity against related arboviruses—steps that would transform this numerically validated platform into a practical tool for rapid, label-free infectious disease diagnostics in the field.</p>
<div class="scienmag-article-metadata"><strong>Subject of Research:</strong> Label-free terahertz metasurface biosensing for chikungunya virus detection using a hybrid graphene–MXene–WS₂–Au–Cu architecture with machine-learning-assisted optimization</p>
<p><strong>Article Title:</strong> Hybrid graphene–MXene–WS₂ terahertz metasurface detects chikungunya virus via machine learning</p>
<p><strong>Article References:</strong> Arunachalam, G., Kalaiarasi, A., Hallur, G., &amp; Parthasarathy, V. (2026). Machine learning-assisted hybrid graphene–MXene–WS₂ terahertz metasurface biosensor for highly sensitive label-free chikungunya virus detection. <em>Results in Optics, 25</em>, Article 101149. <a href="https://doi.org/10.1016/j.rio.2026.101149" target="_blank" rel="noopener noreferrer">https://doi.org/10.1016/j.rio.2026.101149</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1016/j.rio.2026.101149" target="_blank" rel="noopener noreferrer">10.1016/j.rio.2026.101149</a></p>
<p><strong>Keywords:</strong> chikungunya virus detection, computational biosensor design, high sensitivity biosensors, hybrid graphene MXene WS₂, machine learning in biosensing, multilayer architecture, nanomaterial-based sensors, public health diagnostics, refractive index sensing, terahertz metasurface biosensor, virus diagnosis in field settings, XGBoost surrogate model</p>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">192615</post-id>	</item>
		<item>
		<title>New Plasmonic Nanobiosensor Spots Fuel Adulteration at Record Sensitivity</title>
		<link>https://scienmag.com/new-plasmonic-nanobiosensor-spots-fuel-adulteration-at-record-sensitivity/</link>
		
		<dc:creator><![CDATA[Bethany Barker]]></dc:creator>
		<pubDate>Thu, 03 Sep 2026 13:39:32 +0000</pubDate>
				<category><![CDATA[Chemistry]]></category>
		<category><![CDATA[advanced biosensor for hydrocarbons]]></category>
		<category><![CDATA[aluminium antimonide]]></category>
		<category><![CDATA[black phosphorus]]></category>
		<category><![CDATA[cost-effective fuel adulteration testing]]></category>
		<category><![CDATA[environmental impact of fuel adulteration]]></category>
		<category><![CDATA[fuel adulteration]]></category>
		<category><![CDATA[Fuel adulteration detection]]></category>
		<category><![CDATA[graphene]]></category>
		<category><![CDATA[hafnium dioxide]]></category>
		<category><![CDATA[iron sesquioxide]]></category>
		<category><![CDATA[label-free detection technology]]></category>
		<category><![CDATA[MoS2]]></category>
		<category><![CDATA[MoSe2]]></category>
		<category><![CDATA[nanobiosensor]]></category>
		<category><![CDATA[nanotechnology in fuel analysis]]></category>
		<category><![CDATA[plasmonic nanobiosensor]]></category>
		<category><![CDATA[portable fuel quality testing]]></category>
		<category><![CDATA[rapid fuel quality assessment]]></category>
		<category><![CDATA[refractive index change measurement]]></category>
		<category><![CDATA[refractive index sensing]]></category>
		<category><![CDATA[sensitive detection of fuel contamination]]></category>
		<category><![CDATA[surface plasmon resonance]]></category>
		<category><![CDATA[surface plasmon resonance sensor]]></category>
		<category><![CDATA[transfer matrix method]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=186235</guid>

					<description><![CDATA[Researchers have designed a multilayer surface plasmon resonance nanobiosensor combining hafnium dioxide, aluminium antimonide and iron sesquioxide with two-dimensional materials to detect fuel adulteration with record sensitivity.]]></description>
										<content:encoded><![CDATA[<p>Fuel adulteration is one of those quiet crimes that most motorists never see but almost everyone eventually pays for. When cheaper hydrocarbons such as kerosene are blended into commercial gasoline or diesel, engines lose efficiency, critical components wear out faster, and exhaust emissions of particulates and pollutants climb. The financial losses ripple through transport fleets and national economies, while the environmental burden accumulates in city air. Yet detecting diluted fuel has traditionally required laboratory-based techniques such as gas chromatography, mass spectrometry or infrared spectroscopy, all of which demand expensive instrumentation, skilled personnel and hours of processing time. A research team at the Koneru Lakshmaiah Education Foundation in Andhra Pradesh, India, now proposes a way to make fuel quality checks fast, cheap and portable: a label-free plasmonic nanobiosensor that can spot refractive index changes as tiny as 0.001 refractive index units, corresponding to adulteration levels below ten percent.</p>
<p>The new design, reported in the journal Discover Electrochemistry, rests on the well-established physics of surface plasmon resonance, or SPR. In a standard SPR sensor, p-polarized light strikes a thin metal film through a prism, and at a precise incidence angle the photons transfer their energy to collective electron oscillations, known as surface plasmons, at the metal-dielectric interface. That resonance condition depends exquisitely on the refractive index of the medium touching the metal. If the index shifts even slightly, the resonance angle moves, producing a measurable dip in reflected light intensity. Because the technique requires no labels, reagents or chemical processing, it is attractive for real-time, field-deployable monitoring. The catch has always been sensitivity: conventional SPR configurations confine the optical field weakly and suffer high losses, limiting their ability to resolve the minuscule index changes that adulteration produces.</p>
<p>The Indian team, led by Shashank Reddy Perati with Sandeep Boddu, Yesudasu Vasimalla and Santosh Kumar, tackled this limitation by stacking multiple functional layers above the metal film rather than relying on a single noble metal and a lone dielectric spacer. Their architecture follows the Kretschmann configuration and comprises a BAK1 prism, a 54-nanometer silver layer, followed by 2-nanometer hafnium dioxide (HfO2), 0.53-nanometer aluminium antimonide (AlSb) and 0.53-nanometer iron sesquioxide (Fe2O3), with the fuel sample acting as the sensing medium. The researchers chose silver over gold because it delivers lower optical loss and stronger field confinement at the 633-nanometer wavelength of a helium-neon laser. The BAK1 prism, with its refractive index of 1.5704, efficiently couples light into the plasmon modes at that wavelength.</p>
<p>Each added layer plays a distinct optical role. Hafnium dioxide, a high-k dielectric with an index of 1.8943, acts as a spacer that reduces radiation loss and pushes more of the evanescent electromagnetic field toward the sensing interface. Aluminium antimonide, a semiconductor with a complex refractive index of 3.8644 plus a small imaginary component, improves optical coupling and charge redistribution between adjacent layers, enhancing plasmon propagation. Iron sesquioxide, whose index of 3.1251 with modest absorption makes it a high-refractive-index, strongly interacting material, serves as the active sensing layer closest to the fuel. Together, the researchers argue, these layers sharpen the resonance dip, narrow its full width at half maximum, and amplify the angular shift produced by each unit change in refractive index, a synergistic effect that conventional single-dielectric SPR designs cannot match.</p>
<p>To model the sensor&#8217;s response, the team employed the transfer matrix method, calculating Fresnel reflection coefficients for every layer interface and solving the full multilayer reflectance without approximations. The optical constants for each material were taken from established databases, and the sensing medium was swept across refractive indices from 1.4167 to 1.4259, a range chosen to represent fuel samples progressively contaminated with adulterants. Performance was quantified using five metrics: angular sensitivity in degrees per refractive index unit, quality factor, signal-to-noise ratio, figure of merit, and a combined sensitivity factor. Optimizing the silver thickness proved crucial. Sweeping it from 40 to 56 nanometers, the simulations showed that at 54 nanometers the resonance dip became deepest and narrowest, minimum reflectance fell to roughly 0.001, and sensitivity peaked at 188.01 degrees per refractive index unit for the bare multilayer stack.</p>
<p>The biggest leap, however, came from decorating the iron sesquioxide surface with atomically thin two-dimensional materials. The team tested graphene, black phosphorus, molybdenum disulfide (MoS2) and molybdenum diselenide (MoSe2) as overlayers, and then explored multi-layer variants of each. Graphene and MoSe2 contributed chemical stability and durability to the sensor surface, while black phosphorus and MoS2 delivered the largest field enhancements. Stacking several BP sublayers pushed the sensitivity to 389.91 degrees per refractive index unit, the highest value reported in the study, alongside a quality factor of 201.193 per refractive index unit, a signal-to-noise ratio of 0.231 and a figure of merit of 114.481. Multi-layer graphene configurations achieved quality factors above 330 and a figure of merit of 171.71, while MoS2 variants reached a quality factor of 362.77, underscoring how heavily the choice and number of 2D layers shape the plasmonic response.</p>
<p>Intriguingly, the simulations also revealed a hard limit to the layering strategy. When the researchers increased the number of Fe2O3 sublayers, sensitivity climbed from 188.01 to 250.65 and then 348.17 degrees per refractive index unit for two, four and six sublayers respectively, but collapsed again with eight sublayers. The explanation is physical rather than numerical: excessively thick dielectric stacks confine the electromagnetic field so tightly within the layers themselves that too little of the evanescent tail penetrates the sensing medium, shrinking the plasmon-analyte overlap. Black phosphorus showed a similar trade-off, its strong optical absorption and anisotropy damping plasmons when the effective optical thickness grew too large. The lesson, the authors note, is that 2D and dielectric layers enhance sensing only up to an optimized thickness, beyond which added material becomes a liability rather than an asset.</p>
<p>How does the design stack up against the competition? In the comparative table the authors assembled, conventional prism-based SPR sensors using nickel, silver, black phosphorus, tungsten disulfide, MXenes or graphene typically achieve sensitivities between 199 and 300 degrees per refractive index unit, with the best 2024 structure, a prism-silver-silicon-graphene stack, reaching 307.81. The proposed BAK1/Ag/HfO2/AlSb/Fe2O3 architecture with optimized 2D overlayer clearly outperforms all of them at 389.91. The team attributes this advantage to the combined high dielectric confinement of hafnium dioxide, the semiconductor-mediated coupling of aluminium antimonide, and the strong light-matter interaction of iron sesquioxide, which together produce larger resonance-angle shifts for the same index change than any previously reported fuel-adulteration SPR sensor. They also sketch a fabrication pathway in which each layer is deposited stepwise on the BAK1 prism, emphasizing interface uniformity and material compatibility as the keys to practical realization.</p>
<p>The researchers are candid about the remaining hurdles. Silver and aluminium antimonide are vulnerable to environmental degradation, so protective coatings or encapsulation will be needed for long-term field stability, and the added fabrication complexity of the hafnium dioxide layer could introduce unintended optical losses if thickness control slips. The current study is entirely simulation-based, using refractive index values drawn from published fuel-adulteration datasets rather than real fuel samples, and the influence of interfering compounds has not yet been examined. Experimental proof-of-concept trials, fabrication feasibility studies and selectivity analysis with genuine fuel mixtures and different contaminants are planned as next steps. Still, if the laboratory results match the modelling, the payoff could be substantial: an affordable, rapid, label-free sensor capable of catching adulteration below the ten percent threshold in seconds rather than hours, protecting engines, cutting emissions and, by extension, giving regulators and consumers a powerful new tool in the fight against fuel fraud.</p>
<p>The operating wavelength of 633 nanometers is a deliberate choice rooted in practical instrumentation. This is the emission line of the helium-neon laser, a mature, inexpensive and highly stable light source that has anchored optical laboratories for decades. Building a sensor around such a wavelength means the eventual device could rely on commodity optics rather than specialized tunable lasers, an important consideration if the goal is a field-deployable instrument that inspectors or fuel distributors can operate outside a controlled laboratory environment.</p>
<p>Angular interrogation, the readout mode used in this design, is one of several ways to extract a signal from an SPR platform. In this scheme, the incidence angle is scanned while the reflected intensity is monitored, and adulteration is inferred from the shift of the resonance minimum. The sensitivity figure of 389.91 degrees per refractive index unit therefore describes how many degrees the dip moves per unit change in the fuel&#8217;s index, while the quality factor and figure of merit capture how precisely that movement can actually be resolved against the width of the dip. A narrow resonance is as important as a large shift, because a deep but broad minimum is harder to locate accurately in noisy measurements.</p>
<p>The two-dimensional materials layered atop the oxide stack bring more than optical enhancement. Graphene, for instance, is chemically inert and impermeable to most molecules, which helps shield the underlying metal from oxidation while its high carrier mobility supports strong plasmon coupling. Black phosphorus, by contrast, offers a tunable bandgap and pronounced anisotropy that strengthen light-matter interaction, though its susceptibility to ambient degradation is a known limitation that mirrors the encapsulation concerns raised for the metallic layers. Molybdenum disulfide and diselenide round out the family as stable transition-metal dichalcogenides whose optical conductivity can be tuned by layer number.</p>
<p>The transfer matrix method itself is a standard analytical tool for stratified optical media, tracing how each plane wave accumulates phase and amplitude across every interface. Its use here means the reported performance metrics rest on well-validated electromagnetic theory rather than empirical fitting, though the authors&#8217; own caution about the purely computational nature of the study remains pertinent. Real fuels are complex mixtures whose aromatic content, sulfur compounds and additives can alter both the refractive index and the surface chemistry of the sensing layer, so translating simulated gains into measured performance will hinge on how faithfully the modeled dielectric constants match those of genuine kerosene-gasoline blends under field conditions.</p>
<p><strong>Subject of Research:</strong> Design of a label-free surface plasmon resonance nanobiosensor using hafnium dioxide, aluminium antimonide and iron sesquioxide for detecting fuel adulteration</p>
<p><strong>Article Title:</strong> Design of a label free plasmonic nanobiosensor based on hafnium dioxide with aluminium antimonide and iron sesquioxide for fuel adulteration monitoring</p>
<p><strong>Article References:</strong> Perati, S. R., Boddu, S., Vasimalla, Y., &amp; Kumar, S. (2026). Design of a label free plasmonic nanobiosensor based on hafnium dioxide with aluminium antimonide and iron sesquioxide for fuel adulteration monitoring. <em>Discover Electrochemistry, 3</em>(1), Article 78. <a href="https://doi.org/10.1007/s44373-026-00165-8" rel="noopener noreferrer">https://doi.org/10.1007/s44373-026-00165-8</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1007/s44373-026-00165-8" rel="noopener noreferrer">10.1007/s44373-026-00165-8</a></p>
<p><strong>Keywords:</strong> surface plasmon resonance, fuel adulteration, nanobiosensor, hafnium dioxide, aluminium antimonide, iron sesquioxide, black phosphorus, graphene, MoS2, MoSe2, refractive index sensing, transfer matrix method</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">186235</post-id>	</item>
	</channel>
</rss>
