<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>neonatal respiratory monitoring &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/neonatal-respiratory-monitoring/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Fri, 14 Aug 2026 22:35:25 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>neonatal respiratory monitoring &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>Does Finer-Grained Data Improve Bronchopulmonary Dysplasia Prediction?</title>
		<link>https://scienmag.com/does-finer-grained-data-improve-bronchopulmonary-dysplasia-prediction/</link>
		
		<dc:creator><![CDATA[Harold Sullivan]]></dc:creator>
		<pubDate>Fri, 14 Aug 2026 22:35:25 +0000</pubDate>
				<category><![CDATA[Technology and Engineering]]></category>
		<category><![CDATA[bronchopulmonary dysplasia risk prediction]]></category>
		<category><![CDATA[continuous physiological data in neonatology]]></category>
		<category><![CDATA[early detection of bronchopulmonary dysplasia]]></category>
		<category><![CDATA[granular clinical data in neonatal care]]></category>
		<category><![CDATA[impact of detailed clinical data on neonatal outcomes]]></category>
		<category><![CDATA[neonatal clinical data granularity and accuracy]]></category>
		<category><![CDATA[neonatal data-driven decision-making]]></category>
		<category><![CDATA[neonatal intensive care unit data analysis]]></category>
		<category><![CDATA[neonatal respiratory monitoring]]></category>
		<category><![CDATA[neonatal respiratory monitoring technology]]></category>
		<category><![CDATA[predictive modeling for BPD]]></category>
		<category><![CDATA[preterm infant respiratory support]]></category>
		<guid isPermaLink="false">https://scienmag.com/does-finer-grained-data-improve-bronchopulmonary-dysplasia-prediction/</guid>

					<description><![CDATA[Bronchopulmonary dysplasia, or BPD, remains one of the most important chronic complications affecting babies born extremely preterm. The condition develops in immature lungs that are exposed to prolonged oxygen therapy, mechanical ventilation, inflammation and other stresses during the neonatal period. Clinicians often need to estimate which infants are most likely to develop BPD long before [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Bronchopulmonary dysplasia, or BPD, remains one of the most important chronic complications affecting babies born extremely preterm. The condition develops in immature lungs that are exposed to prolonged oxygen therapy, mechanical ventilation, inflammation and other stresses during the neonatal period. Clinicians often need to estimate which infants are most likely to develop BPD long before the diagnosis can be formally confirmed, because that forecast can influence respiratory support, nutritional planning, monitoring and discussions with families. A new article in <em>Pediatric Research</em> asks whether the growing volume and precision of clinical data can genuinely improve that prediction. In “Does more granular data equal better bronchopulmonary dysplasia prediction?”, E.M. Taylor, D.G. Tingay and S.B. Axford examine a question at the centre of modern neonatal medicine: whether more detailed information automatically produces more reliable medical insight.</p>
<p>The appeal of granular data is easy to understand. A conventional clinical record may describe an infant’s respiratory status using broad categories, such as whether the baby is receiving oxygen or mechanical ventilation on a particular day. More granular systems can capture oxygen concentration, airway pressure, respiratory rate, oxygen saturation and heart rate continuously or at very short intervals. They may also record the timing of changes in ventilator settings, episodes of desaturation, blood-gas measurements, medication exposure, weight changes and patterns of respiratory instability. In theory, these high-resolution data streams could reveal subtle differences between infants whose lungs are recovering and those who are moving toward chronic respiratory disease. Advanced statistical models and machine-learning systems can then search for combinations of variables that might be difficult for clinicians to recognise in real time.</p>
<p>Yet the relationship between data detail and predictive accuracy is not straightforward. A larger dataset may contain more biological information, but it may also contain more noise. Neonatal monitoring systems generate frequent measurements that can be affected by motion, poor sensor contact, calibration problems or clinical interruptions. A transient change in oxygen saturation may represent a meaningful respiratory event, or it may reflect an artefact. Ventilator data can be equally complex: a recorded pressure setting does not always indicate the pressure actually reaching the infant’s lungs, and the same setting may have different physiological effects depending on lung compliance, airway resistance and the infant’s breathing effort. Prediction models must therefore distinguish clinically meaningful signals from the enormous background of imperfect observations.</p>
<p>BPD itself also complicates the task. It is not a single, uniform disease with one clearly defined biological pathway. The condition can emerge through different combinations of immaturity, inflammation, infection, oxygen toxicity, fluid exposure and mechanical injury. Two infants may meet the same clinical definition while having very different lung structure and future respiratory needs. Definitions of BPD have also evolved, with different approaches incorporating the level of respiratory support, oxygen requirement and the timing of assessment. If the outcome being predicted is not consistently defined, even an exceptionally sophisticated algorithm may appear inaccurate simply because it is learning to predict a moving target.</p>
<p>The timing of prediction is another critical issue. A model that forecasts BPD shortly before the diagnostic assessment may perform well because it has access to information that already reflects established lung disease. That may be statistically useful but clinically less valuable than a model capable of identifying risk earlier, when treatment and surveillance decisions could still be changed. Researchers must also prevent “data leakage,” a problem that occurs when information recorded after the relevant prediction point accidentally enters the model. For example, later respiratory support or outcomes may be embedded in a dataset in ways that allow an algorithm to anticipate the diagnosis without producing a genuinely early forecast. Granular data can increase this risk because the record contains a detailed timeline of events.</p>
<p>The article’s central question therefore reaches beyond the technical performance of any single prediction tool. It asks what kind of information should be considered valuable in neonatal care. A model may achieve a higher numerical accuracy by using hundreds or thousands of measurements, but that does not necessarily mean it will improve decisions at the bedside. Clinicians need predictions that are interpretable, timely and robust across hospitals, equipment platforms and patient populations. If an algorithm identifies a baby as high risk, medical teams need to understand which features drove that assessment and whether those features represent modifiable factors, unavoidable consequences of extreme prematurity or merely statistical associations. Without that context, a prediction may be precise in a mathematical sense while remaining difficult to act upon.</p>
<p>Data quality and missingness are particularly important in neonatal intensive care. Measurements are not collected evenly from every infant. A baby who is unstable may undergo more blood tests and receive more frequent monitoring than a baby who is improving. Some variables may be absent because they were not clinically necessary, while others may be missing because of equipment limitations or transfer between units. These patterns are not random; they can themselves reflect illness severity, staffing, local practice and resource availability. If a model interprets missing data as if it were neutral, it may produce biased predictions. A system developed in one neonatal unit may also struggle elsewhere, where clinicians use different ventilation strategies, monitoring devices or documentation practices.</p>
<p>There is also a practical cost to collecting, storing and processing high-resolution information. Continuous physiological data require technical infrastructure, secure data management and carefully designed systems capable of translating streams of numbers into clinically meaningful summaries. Neonatal teams already work in environments saturated with alarms and digital records. Adding more alerts or complex risk scores could increase cognitive load rather than improve care. For a prediction model to be useful, its output must fit into clinical workflows, communicate uncertainty and avoid encouraging unnecessary interventions. A risk estimate should support professional judgment, not replace it. In this setting, the most effective model may not be the one that uses the greatest number of variables, but the one that extracts a small set of dependable signals and presents them at the right moment.</p>
<p>The discussion by Taylor, Tingay and Axford arrives as neonatal researchers increasingly explore artificial intelligence, continuous monitoring and large-scale clinical databases. The promise is substantial: better prediction could help identify infants who need closer follow-up, guide research into prevention and improve the design of clinical trials. But the paper’s title highlights a necessary caution. More granular data may reveal important physiology, yet detail alone does not guarantee truth, fairness or clinical usefulness. The value of a dataset depends on how accurately it measures biology, how consistently outcomes are defined, how transparently models are evaluated and whether predictions work beyond the environment in which they were created. For BPD, the next advance may come not from collecting every possible data point, but from combining technically sound measurement with careful clinical reasoning. In neonatal medicine, better prediction will ultimately be judged not by the size of the database, but by whether it helps vulnerable infants receive safer and more timely care.</p>
<p><strong>Subject of Research</strong>: Bronchopulmonary dysplasia prediction in preterm infants</p>
<p><strong>Article Title</strong>: Does more granular data equal better bronchopulmonary dysplasia prediction?</p>
<p><strong>Article References</strong>: Taylor, E.M., Tingay, D.G. &amp; Axford, S.B. “Does more granular data equal better bronchopulmonary dysplasia prediction?” <i>Pediatric Research</i> (2026). <a href="https://doi.org/10.1038/s41390-026-05374-w">https://doi.org/10.1038/s41390-026-05374-w</a></p>
<p><strong>Image Credits</strong>: AI Generated</p>
<p><strong>DOI</strong>: <a href="https://doi.org/10.1038/s41390-026-05374-w">https://doi.org/10.1038/s41390-026-05374-w</a></p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">179360</post-id>	</item>
		<item>
		<title>Machine Learning Predicts Bronchopulmonary Dysplasia Seven Days After Birth Using Respiratory Data</title>
		<link>https://scienmag.com/machine-learning-predicts-bronchopulmonary-dysplasia-seven-days-after-birth-using-respiratory-data/</link>
		
		<dc:creator><![CDATA[Blake Davidson]]></dc:creator>
		<pubDate>Fri, 17 Jul 2026 17:53:13 +0000</pubDate>
				<category><![CDATA[Technology and Engineering]]></category>
		<category><![CDATA[artificial intelligence in pediatric healthcare]]></category>
		<category><![CDATA[bronchopulmonary dysplasia prediction]]></category>
		<category><![CDATA[clinical decision support tools for neonatology]]></category>
		<category><![CDATA[early detection of BPD]]></category>
		<category><![CDATA[early intervention in neonatal lung conditions]]></category>
		<category><![CDATA[early warning systems for neonatal respiratory complications]]></category>
		<category><![CDATA[longitudinal respiratory data analysis]]></category>
		<category><![CDATA[machine learning in neonatal care]]></category>
		<category><![CDATA[neonatal respiratory monitoring]]></category>
		<category><![CDATA[predictive modeling for preterm infants]]></category>
		<category><![CDATA[respiratory signal analysis for lung disease]]></category>
		<category><![CDATA[time-series analysis of infant respiratory data]]></category>
		<guid isPermaLink="false">https://scienmag.com/machine-learning-predicts-bronchopulmonary-dysplasia-seven-days-after-birth-using-respiratory-data/</guid>

					<description><![CDATA[In a breakthrough that could reshape early care for premature babies, researchers report a machine-learning system designed to forecast bronchopulmonary dysplasia (BPD) with remarkable speed. BPD—a chronic lung condition that remains a major cause of long-term respiratory problems—often becomes evident only after weeks, limiting the window for timely, targeted intervention. The study, published in Pediatric [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>In a breakthrough that could reshape early care for premature babies, researchers report a machine-learning system designed to forecast bronchopulmonary dysplasia (BPD) with remarkable speed. BPD—a chronic lung condition that remains a major cause of long-term respiratory problems—often becomes evident only after weeks, limiting the window for timely, targeted intervention.</p>
<p>The study, published in <em>Pediatric Research</em>, focuses on predicting whether an infant will develop BPD within just one week after birth. The key idea is to move beyond static measurements taken at a single time point, and instead analyze continuously recorded physiological signals that reflect the newborn’s evolving respiratory status.</p>
<p>Rather than relying solely on standard clinical markers, the model ingests respiratory and oxygenation time-series data—sequences that capture how breathing patterns and oxygen needs change hour by hour. These trajectories can reveal subtle trajectories of lung stress long before diagnosis is confirmed, potentially offering an earlier warning signal for clinicians.</p>
<p>Technically, the authors build an ML framework trained to detect patterns across the temporal dynamics of those signals. By converting time-series data into informative features, the system learns relationships between early fluctuations in respiratory mechanics and oxygen requirements and later BPD outcomes.</p>
<p>The researchers’ aim is not merely prediction, but actionable timing: a tool that can flag high-risk infants early enough to guide therapeutic decisions. If validated broadly, this approach could support earlier risk stratification and more personalized monitoring strategies in neonatal intensive care units.</p>
<p>Early prediction could also improve clinical trial design, allowing researchers to enroll infants closer to the true onset of disease processes. That could accelerate evaluation of interventions meant to prevent or mitigate BPD rather than respond after it has established.</p>
<p>The work underscores a growing trend in neonatal medicine: pairing high-frequency data streams with AI to extract clinically relevant information from complex, time-dependent physiology. The authors’ results suggest that respiratory and oxygenation patterns carry predictive information that standard snapshots may miss.</p>
<p>As premature care becomes increasingly data-driven, models like this could help translate continuous monitoring into earlier, more precise clinical action—turning raw vital signals into a forecast of lung outcomes.</p>
<p>Crucially, the study positions respiratory and oxygenation time-series as a practical input source, since these measurements are commonly captured in neonatal settings. That could make eventual deployment more feasible if future studies confirm generalizability across populations and equipment types.</p>
<p>Overall, the reported system represents a viral-worthy leap toward earlier BPD risk prediction—bringing the promise of ML-fueled prevention closer to the bedside.</p>
<p><strong>Subject of Research</strong>: Prediction of bronchopulmonary dysplasia (BPD) in premature infants using machine learning and respiratory/oxygenation time-series data.</p>
<p><strong>Article Title</strong>: Prediction of bronchopulmonary dysplasia seven days after birth using respiratory and oxygenation timeseries with machine learning.</p>
<p><strong>Article References</strong>: Bennis, F.C., Onland, W., van der Vorst, J.P. <i>et al.</i> Prediction of bronchopulmonary dysplasia seven days after birth using respiratory and oxygenation timeseries with machine learning. <i>Pediatr Res</i> (2026). <a href="https://doi.org/10.1038/s41390-026-05301-z">https://doi.org/10.1038/s41390-026-05301-z</a></p>
<p><strong>Image Credits</strong>: AI Generated</p>
<p><strong>DOI</strong>: <a href="https://doi.org/10.1038/s41390-026-05301-z">https://doi.org/10.1038/s41390-026-05301-z</a></p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">173608</post-id>	</item>
		<item>
		<title>Breath-by-Breath Lung Gas Detection in Neonatal Mannequin</title>
		<link>https://scienmag.com/breath-by-breath-lung-gas-detection-in-neonatal-mannequin/</link>
		
		<dc:creator><![CDATA[Harold Sullivan]]></dc:creator>
		<pubDate>Sat, 10 Jan 2026 08:11:57 +0000</pubDate>
				<category><![CDATA[Technology and Engineering]]></category>
		<category><![CDATA[advancements in newborn critical care]]></category>
		<category><![CDATA[breath-by-breath lung gas detection]]></category>
		<category><![CDATA[GASMAS technology in medicine]]></category>
		<category><![CDATA[high-fidelity neonatal mannequin]]></category>
		<category><![CDATA[innovative neonatal care solutions]]></category>
		<category><![CDATA[lung gas volume measurement techniques]]></category>
		<category><![CDATA[neonatal patient monitoring innovations]]></category>
		<category><![CDATA[neonatal respiratory monitoring]]></category>
		<category><![CDATA[non-invasive lung function assessment]]></category>
		<category><![CDATA[optical gas detection methods]]></category>
		<category><![CDATA[pediatric respiratory diagnostics]]></category>
		<category><![CDATA[real-time pulmonary function monitoring]]></category>
		<guid isPermaLink="false">https://scienmag.com/breath-by-breath-lung-gas-detection-in-neonatal-mannequin/</guid>

					<description><![CDATA[A groundbreaking breakthrough in neonatal respiratory monitoring has emerged from recent research employing Gas in Scattering Media Absorption Spectroscopy (GASMAS) to detect lung gas volumes on a breath-by-breath basis. This innovative study, published in Pediatric Research, introduces a cutting-edge technology capable of providing real-time insights into pulmonary function in neonates, potentially revolutionizing critical care in [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>A groundbreaking breakthrough in neonatal respiratory monitoring has emerged from recent research employing Gas in Scattering Media Absorption Spectroscopy (GASMAS) to detect lung gas volumes on a breath-by-breath basis. This innovative study, published in Pediatric Research, introduces a cutting-edge technology capable of providing real-time insights into pulmonary function in neonates, potentially revolutionizing critical care in newborn medicine. Utilizing a high-fidelity neonatal mannequin, the research team led by Panaviene and colleagues has demonstrated the capacity of GASMAS to measure dynamic lung gas volumes non-invasively, heralding a significant advancement in both respiratory diagnostics and patient monitoring.</p>
<p>Lung function monitoring in neonates has long posed a considerable challenge due to the delicate and rapidly changing physiological parameters of newborns. Traditional methods, such as blood gas analysis or ventilator monitoring, offer limited temporal resolution and often involve invasive procedures that add risk and discomfort for these vulnerable patients. Against this backdrop, the adoption of GASMAS technology provides a novel optical approach that leverages the unique spectral signatures of gases trapped in biological tissues. By applying spectroscopic principles, GASMAS accurately quantifies gas concentrations—specifically those of molecular oxygen and water vapor—within the lung environment, enabling precise lung volume evaluation without direct contact or interference.</p>
<p>The neonatal mannequin used in this study serves as a crucial platform for simulating real-world clinical scenarios, allowing detailed calibration and validation of the GASMAS apparatus. This controlled environment affords researchers the ability to replicate varying respiratory patterns and lung conditions relevant to a broad spectrum of neonatal health states. By continuously measuring the lung volumes on a breath-by-breath basis, the investigators have shown consistent correlation between optical signals obtained via GASMAS and the known volumes programmed into the mechanical lung simulator of the mannequin. Such high-resolution data capture could significantly enhance clinicians’ ability to detect subtle changes in lung function that precede overt respiratory distress.</p>
<p>Technical implementation of GASMAS relies on near-infrared light passing through scattering tissues, with specific absorption peaks corresponding to the gaseous components within the lung’s alveolar spaces. By meticulously analyzing these modulated optical signals, the instrument deciphers the concentration levels and changes of pulmonary gases during the respiratory cycle. This spectroscopic technique offers remarkable temporal resolution, allowing for near-instantaneous feedback on lung volume fluctuations. Such capabilities open the door to not only tracking ventilation efficacy but also assessing the success of therapeutic interventions in real-time, a feat previously unattainable without invasive or cumbersome methods.</p>
<p>Beyond its clinical implications, the GASMAS technique’s non-invasive nature represents a pivotal step toward minimizing distress and potential harm in neonatal care. Conventional monitoring often includes procedures that can increase infection risk or require sedation, both of which are highly undesirable in fragile infants. The optical gas sensing method eliminates these concerns by forgoing physical intrusion, reducing the risk profile, and improving the comfort of neonatal patients. Additionally, the portability and speed of GASMAS technology may facilitate broader deployment across neonatal intensive care units (NICUs), offering standardized and reproducible lung volume monitoring that can enhance patient outcomes globally.</p>
<p>The study’s results have far-reaching implications for diagnosing and managing a host of neonatal pulmonary conditions, including respiratory distress syndrome, bronchopulmonary dysplasia, and apnea of prematurity. Early and precise detection of compromised lung function enables timely interventions, which are crucial in this delicate patient population. Moreover, continuous breath-by-breath monitoring supports tailored ventilator settings that adapt to the neonate’s immediate physiological status, reducing the risk of lung injury caused by over- or under-ventilation. This adaptability marks a significant leap toward personalized respiratory care in neonatology.</p>
<p>Importantly, the integration of GASMAS with existing respiratory support systems could pave the way for highly automated care environments, where sensor inputs continuously guide therapeutic decisions. Imagine a closed-loop ventilation system that adjusts parameters based on live spectroscopic feedback from the lungs, optimizing oxygen delivery while minimizing damage. Such systems could dramatically reduce the workload on healthcare providers, ensuring that neonates receive vigilant, real-time monitoring irrespective of nurse or physician availability, thus enhancing patient safety and care quality.</p>
<p>The research also touches upon the methodological challenges overcome to harness GASMAS in a scattering medium as complex as human lung tissue, albeit simulated here by a mannequin. Biological tissues scatter and absorb light in intricate ways that complicate spectroscopic measurements, but advances in optical modeling and calibration algorithms have allowed the team to isolate gas-specific signals reliably. This achievement not only demonstrates the technical feasibility of GASMAS for pulmonary monitoring but also lays the groundwork for future in vivo studies to verify and refine this approach in clinical settings.</p>
<p>Further exploration is warranted to extend this technology beyond mannequins and into live neonatal patients, where variables such as spontaneous movement, varying tissue properties, and heterogeneous lung pathology could influence signal acquisition. The refinement of sensor design, signal processing techniques, and adaptive calibration protocols will be critical to translating this promising approach into practical bedside tools that can withstand the complexities of real-world neonatal care scenarios.</p>
<p>Moreover, the potential applications of GASMAS extend beyond neonatology. Similar principles could be adapted for respiratory monitoring in pediatric and adult patients, especially those requiring prolonged mechanical ventilation or suffering from chronic pulmonary diseases. The non-invasive, continuous nature of the measurements confers broad utility, initiating a paradigm shift toward more precise and less distressing pulmonary diagnostics across age groups and clinical settings.</p>
<p>In a broader biomedical optics context, this research epitomizes the fusion of photonics, spectroscopy, and clinical medicine to solve pressing healthcare challenges. As biomedical optics technology continues to mature, integration with artificial intelligence for data interpretation and predictive analytics could further enhance the granularity and clinical value of GASMAS-derived parameters. Such integration would empower healthcare teams with sophisticated decision-support tools, enabling earlier identification of subtle pathophysiological changes and preemptive clinical actions.</p>
<p>The study by Panaviene and colleagues represents a landmark in respiratory physiology research, demonstrating the first breath-by-breath lung gas volume detection with GASMAS in a neonatal mannequin. This milestone embodies a synthesis of innovative optical physics, biomedical engineering, and neonatal medicine, promising a future where continuous, fiercely accurate lung monitoring is seamlessly woven into neonatal care. It is an inspiring development that reflects the transformative potential of multi-disciplinary research aimed at saving the most vulnerable lives—those of newborn infants.</p>
<p>As this field advances, the collaborative efforts among physicists, engineers, neonatologists, and clinical researchers will be essential to accelerate translation, optimize protocols, and ensure safety and efficacy in human subjects. The promise of GASMAS lies not only in its impressive technical achievements but also in its humanitarian potential to enhance neonatal survival and quality of life through more responsive and compassionate care.</p>
<p>In conclusion, breath-by-breath lung gas volume detection using GASMAS technology signifies a visionary leap forward in neonatology and pulmonary medicine. By marrying sophisticated spectroscopic instrumentation with the clinical imperative for non-invasive, precise monitoring, this research has set the stage for a new era of neonatal respiratory management. Continued innovation and clinical validation will determine how rapidly this promising technology transitions from mannequin models to routine use in NICUs worldwide, potentially reshaping neonatal care for generations to come.</p>
<hr />
<p><strong>Subject of Research</strong>: Breath-by-breath lung gas volume detection in neonates using Gas in Scattering Media Absorption Spectroscopy (GASMAS)</p>
<p><strong>Article Title</strong>: Breath-by-breath lung gas volume detection using GASMAS in a neonatal mannequin</p>
<p><strong>Article References</strong>:<br />
Panaviene, J., Lanka, P., Grygoryev, K. <em>et al.</em> Breath-by-breath lung gas volume detection using GASMAS in a neonatal mannequin. <em>Pediatr Res</em> (2026). <a href="https://doi.org/10.1038/s41390-025-04699-2">https://doi.org/10.1038/s41390-025-04699-2</a></p>
<p><strong>Image Credits</strong>: AI Generated</p>
<p><strong>DOI</strong>: 10 January 2026</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">125064</post-id>	</item>
	</channel>
</rss>
