<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>multi-material 3D printing &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/multi-material-3d-printing/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Oct 2026 06:39:52 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>multi-material 3D printing &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>3D-Printed Heart Valves Copy Nature&#8217;s Collagen Blueprint to Beat Fatigue</title>
		<link>https://scienmag.com/3d-printed-heart-valves-copy-natures-collagen-blueprint-to-beat-fatigue/</link>
		
		<dc:creator><![CDATA[Denise Maddox]]></dc:creator>
		<pubDate>Fri, 02 Oct 2026 06:39:52 +0000</pubDate>
				<category><![CDATA[Medicine]]></category>
		<category><![CDATA[3D-printed biomimetic heart valves]]></category>
		<category><![CDATA[additive manufacturing]]></category>
		<category><![CDATA[advancements in cardiovascular device engineering]]></category>
		<category><![CDATA[aortic valve]]></category>
		<category><![CDATA[biocompatible materials for heart valve prostheses]]></category>
		<category><![CDATA[biomimetic fiber reinforcement]]></category>
		<category><![CDATA[cardiovascular engineering]]></category>
		<category><![CDATA[collagen fiber architecture]]></category>
		<category><![CDATA[collagen fiber architecture in tissue engineering]]></category>
		<category><![CDATA[collagen-inspired polymeric valve design]]></category>
		<category><![CDATA[durable artificial heart valves]]></category>
		<category><![CDATA[finite element analysis]]></category>
		<category><![CDATA[hemodynamics]]></category>
		<category><![CDATA[long-lasting polymeric heart valve development]]></category>
		<category><![CDATA[multi-material 3D printing]]></category>
		<category><![CDATA[multi-material 3D printing in biomedical engineering]]></category>
		<category><![CDATA[overcoming limitations of mechanical and tissue valves]]></category>
		<category><![CDATA[polycarbonate urethane]]></category>
		<category><![CDATA[polymeric heart valves]]></category>
		<category><![CDATA[reducing strain energy in valve leaflets]]></category>
		<category><![CDATA[strain energy density]]></category>
		<category><![CDATA[thermoforming]]></category>
		<category><![CDATA[thermoforming of 3D-printed heart valves]]></category>
		<category><![CDATA[tissue-engineered heart valve replacements]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=226194</guid>

					<description><![CDATA[Researchers at the Technion have 3D-printed polymeric aortic valves with embedded, biomimetic PETG fiber networks that cut predicted leaflet strain energy density by up to 26 percent while preserving valve opening and regurgitation performance.]]></description>
										<content:encoded><![CDATA[<p>Every heartbeat subjects the aortic valve to roughly 80 million flex cycles over a lifetime, and no artificial replacement has ever matched that endurance without a costly trade-off. Mechanical valves last for decades but force patients onto lifelong blood thinners, while tissue valves flow naturally yet degenerate within ten to fifteen years. Now a team at the Technion–Israel Institute of Technology has unveiled a strikingly elegant third path: a polymeric heart valve whose leaflets carry an internal fiber skeleton copied almost directly from the collagen architecture of the native valve itself, printed layer by layer with a multi-material 3D printer and then thermoformed into its final shape. The work, published in the Annals of Biomedical Engineering, reports that this biomimetic reinforcement cut the predicted strain energy density inside the leaflets by up to 26 percent while barely compromising how wide the valve opens.</p>
<p>The problem the researchers attacked is one of the most stubborn in cardiovascular engineering. Polymeric heart valves have been pursued since the mid-twentieth century because they promise the durability of mechanical prostheses combined with the gentle, physiological blood flow of biological ones. Polycarbonate urethane, or PCU, has long been a favorite matrix material thanks to its resilience, biocompatibility and ability to be formed into thin, flexible leaflets. Yet polymeric valves still suffer from thrombosis, calcification, viscoelastic creep and, above all, insufficient fatigue resistance under cyclic loading. Elevated mechanical stress has been linked for decades to structural deterioration and calcification in heart valves, and strain energy density is widely recognized as a fatigue-related parameter in elastomers. Reduce the mechanical demand inside each leaflet, the reasoning goes, and the valve should live longer.</p>
<p>The Technion team&#8217;s inspiration came from biology rather than materials chemistry. Native aortic valve leaflets owe their remarkable longevity to an organized collagen fiber network in which circumferentially dominant bundles carry most of the tensile load during diastole while preserving the radial compliance needed for the valve to swing open during systole. Earlier attempts at fiber reinforcement typically bolted simplified radial or cross-hatched meshes onto the leaflet surface, which risks mechanical damage and adverse blood–material interactions. The new approach instead buries the reinforcement entirely inside the leaflet volume, following curvilinear trajectories mapped from microscopy of porcine aortic leaflets, with fibers converging at the commissures just as collagen does in living tissue.</p>
<p>Realizing that architecture demanded an unusual manufacturing workflow. The researchers printed each valve not as a finished three-dimensional object but as a flat, unfolded sheet on a Prusa XL multi-material extrusion printer, depositing medical-grade Bionate 90A polycarbonate urethane as the matrix and stiffer PETG filaments as reinforcing fibers laid into preformed channels at roughly the leaflet&#8217;s mid-thickness. The flat construct was then wrapped around a stereolithography-printed mold, its edges thermally welded into a cylindrical root, and finally pressed in a heated two-part mold that generated the final leaflet geometry while consolidating the printed layers. Scanning electron microscopy confirmed that the PETG fibers remained fully encapsulated in a consolidated PCU matrix, with no visible interfacial gaps or debonding even after an hour of pulsatile flow testing corresponding to roughly 3,600 cardiac cycles.</p>
<p>To isolate the effect of fiber architecture, the team built four valve designs with identical geometry and an identical reinforcement volume fraction of about seven percent: an unreinforced baseline, a horizontal layout of thirteen circumferential fibers, a ply layout of crossing fibers in an X pattern, and the biomimetic network. Two leaflet thicknesses were compared computationally, 0.3 millimeters and a native-like 0.2 millimeters, with fiber diameters scaled accordingly from 0.15 to 0.10 millimeters. Finite element simulations in Abaqus, using a Marlow hyperelastic model calibrated against uniaxial tensile tests of the printed PCU, quantified stress, principal logarithmic strain and strain energy density at peak diastolic loading.</p>
<p>The results revealed a subtle and somewhat counterintuitive picture. No single metric crowned one design as the universal winner. The ply architecture produced the lowest localized peak stress, the horizontal layout most strongly restricted deformation, and the biomimetic design achieved the lowest strain energy density, 0.14 versus 0.18 megajoules per cubic meter in the unreinforced 0.3-millimeter valve, and 0.25 versus 0.34 megajoules per cubic meter in the thinner 0.2-millimeter version. Because strain energy density reflects the elastic energy stored in the material with every loading cycle, the biomimetic network&#8217;s advantage suggests reduced fatigue demand precisely where it matters most. Notably, the reinforcement&#8217;s influence grew dramatically as the leaflet thinned: in the thicker valve the matrix carried much of the load itself, while in the thinner design a greater share of stress flowed into the fibers, making the choice of architecture far more consequential.</p>
<p>Notched tensile experiments added a durability angle that pure simulation cannot provide. Coupons reinforced at 45 degrees to the loading direction absorbed the most energy before peak load and tolerated the greatest stretch, significantly outperforming unreinforced polymer in maximum nominal ligament stress. Inclined fibers, it turns out, help a damaged leaflet keep carrying load, a property that could prove decisive in resisting tear propagation over years of service.</p>
<p>The hydrodynamic payoff was verified in a pulsatile flow loop operating at a physiological cardiac output of five liters per minute, with measurements referenced to the ISO 5840 standard. High-speed imaging showed stable leaflet motion with no flutter in any configuration. The unreinforced valve opened widest, with a geometric orifice area of 2.34 square centimeters, while the three reinforced designs clustered between 1.89 and 1.95 square centimeters. Crucially, however, the effective orifice area, which captures actual flow performance, differed only modestly among all four designs, and regurgitation fractions were statistically indistinguishable. The biomimetic valve thus surrendered little functional performance while delivering the most favorable mechanical environment among the reinforced options.</p>
<p>The study is candid about its limits. The simulations used a structural-only formulation rather than full fluid–structure interaction, overpredicting valve opening, and the models assumed ideal circular fibers even though printed cross-sections became progressively elongated at smaller diameters. Long-term durability, accelerated wear, fatigue and creep testing remain to be done, and the authors emphasize that the workflow is a research prototyping platform rather than a clinically ready manufacturing route. A symmetric twisting mode observed during simulated closure of the thin biomimetic valve was traced to the free-edge fiber implementation, suggesting that tapered or staggered fiber terminations could resolve the instability without abandoning the biomimetic concept.</p>
<p>Even so, the demonstration marks a genuine milestone: proof that complex, load-aligned, fully embedded reinforcement architectures can be fabricated inside leaflets thinner than a human hair is thick, and that copying the heart&#8217;s own collagen blueprint is a viable engineering strategy rather than mere biomimetic poetry. If subsequent wear testing confirms the promise hinted at by the strain energy results, the humble 3D printer may one day produce valves that outlast the patients who receive them.</p>
<p><strong>Subject of Research:</strong> Biomimetic fiber-reinforced 3D-printed polymeric aortic heart valves for improved leaflet stress distribution and durability</p>
<p><strong>Article Title:</strong> Design and Fabrication of 3D-Printed Biomimetic Fiber-Reinforced Polymeric Aortic Valves for Improved Stress Distribution</p>
<p><strong>Article References:</strong> Tal, O., Kreinin, Y., Korneyev, D., Levenberg, S., &amp; Korin, N. (2026). Design and Fabrication of 3D-Printed Biomimetic Fiber-Reinforced Polymeric Aortic Valves for Improved Stress Distribution. <em>Annals of Biomedical Engineering</em>. <a href="https://doi.org/10.1007/s10439-026-04371-8" rel="noopener noreferrer">https://doi.org/10.1007/s10439-026-04371-8</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1007/s10439-026-04371-8" rel="noopener noreferrer">10.1007/s10439-026-04371-8</a></p>
<p><strong>Keywords:</strong> polymeric heart valves, biomimetic fiber reinforcement, multi-material 3D printing, polycarbonate urethane, aortic valve, finite element analysis, strain energy density, thermoforming, hemodynamics, collagen fiber architecture, additive manufacturing, cardiovascular engineering</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">226194</post-id>	</item>
		<item>
		<title>3D-Printed Magnetic Soft Robots Change Shape Mid-Movement on Command</title>
		<link>https://scienmag.com/3d-printed-magnetic-soft-robots-change-shape-mid-movement-on-command/</link>
		
		<dc:creator><![CDATA[Denise Maddox]]></dc:creator>
		<pubDate>Tue, 22 Sep 2026 22:58:31 +0000</pubDate>
				<category><![CDATA[Technology and Engineering]]></category>
		<category><![CDATA[3D-printed soft robotics]]></category>
		<category><![CDATA[adaptive soft robot design]]></category>
		<category><![CDATA[advanced composite materials in robotics]]></category>
		<category><![CDATA[bioinspired robotics]]></category>
		<category><![CDATA[direct ink writing]]></category>
		<category><![CDATA[direct ink writing in soft robotics]]></category>
		<category><![CDATA[dual magnetic fields]]></category>
		<category><![CDATA[Fe3O4 particles]]></category>
		<category><![CDATA[locomotion modes]]></category>
		<category><![CDATA[magnetic actuation]]></category>
		<category><![CDATA[magnetic field-controlled robot gait]]></category>
		<category><![CDATA[magnetically actuated soft robots]]></category>
		<category><![CDATA[multi-material 3D printing]]></category>
		<category><![CDATA[multi-modal movement in soft robots]]></category>
		<category><![CDATA[multifunctional soft robotics applications]]></category>
		<category><![CDATA[NdFeB particles]]></category>
		<category><![CDATA[programmable 3D printing for soft structures]]></category>
		<category><![CDATA[remotely controlled shape-changing robots]]></category>
		<category><![CDATA[shape memory polymers]]></category>
		<category><![CDATA[shape morphing]]></category>
		<category><![CDATA[shape-shifting soft robots]]></category>
		<category><![CDATA[smart materials]]></category>
		<category><![CDATA[soft polymers with magnetic particles]]></category>
		<category><![CDATA[soft robotics]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=208579</guid>

					<description><![CDATA[Researchers have 3D-printed a magnetic soft robot that can morph its body shape on the fly, switching between crawling, rolling, and jumping without ever touching the machine.]]></description>
										<content:encoded><![CDATA[<p>Soft robots have long promised the kind of adaptable, muscle-like movement that rigid machines cannot match, but most of them can only ever walk, grip, or swim in the single way their designers gave them. A new study published in Advanced Composites and Hybrid Materials changes that calculus. A team led by researchers at Jilin University, working with colleagues at the Liaoning Academy of Materials and the University of Oxford, has fabricated a magnetically actuated soft robot that can reshape its own body while it is still moving, and then lock into the new configuration and carry on in a completely different gait. The robot crawls, rolls, and jumps, and it decides which mode to use not through a mechanical gearbox but through nothing more than carefully choreographed magnetic fields applied from outside the body.</p>
<p>The enabling technology is direct ink writing, an extrusion-based form of 3D printing in which a viscous ink is pushed through a fine nozzle along programmable toolpaths, building up complex three-dimensional structures layer by layer. What makes this work distinctive is not the printer itself but the inks. The researchers formulated soft polymer matrices loaded with two kinds of functional magnetic particles. Neodymium-iron-boron, or NdFeB, particles provide the strong, permanent magnetization that lets an external field push and pull on the robot&#8217;s limbs. Iron oxide, Fe3O4, particles play a subtler role: they concentrate heat locally when the material is exposed to a rapidly oscillating magnetic field. By printing these two particle-laden inks alongside plain soft polymer into a single monolithic architecture, the team created a robot in which actuation, heating, and structural compliance are distributed exactly where they are needed.</p>
<p>The cleverness of the design lies in how the two particle systems divide the labor. When a high-frequency magnetic field is applied, the Fe3O4 particles act as microscopic heaters, warming only the regions where they were printed. Those regions are made of shape memory polymers, materials that soften dramatically above a transition temperature and then stiffen again on cooling, remembering whatever shape they were molded into while soft. By selectively heating different zones of the robot, the operators can temporarily reduce the stiffness of specific parts of the body, allowing the low-frequency magnetic field that simultaneously drives the NdFeB-rich segments to fold or twist the robot into a new geometry. Once the high-frequency field is switched off, the shape memory polymer cools and hardens, locking the new shape in place without any continuous power input.</p>
<p>This combination of on-demand softening and magnetic reshaping is what the authors describe as on-the-fly shape morphing, and the phrase is meant literally. The robot does not need to stop, be picked up, or be reprogrammed between modes. While it is mid-crawl, an operator can ramp up the high-frequency field, watch a segment of the body go limp and refold under the steering field, then drop the frequency and the robot resumes locomotion in its new configuration, for example switching from a crawling posture suited to squeezing through a narrow channel to a compact rolling form suited to open ground. Because the entire body is one printed piece, there are no hinges, screws, or assemblies to fail, and the shape transition is reversible and repeatable.</p>
<p>Demonstrating robust locomotion was a central part of the study. The team showed the robot transitioning among at least three distinct gaits: crawling, in which the body deforms cyclically to generate friction-anchored forward motion; rolling, in which the locked body shape lets the field tumble the robot efficiently across flat terrain; and jumping, in which stored elastic energy is released in a rapid burst to hop over obstacles. Each mode places different demands on the body&#8217;s stiffness and geometry, which is precisely why the ability to reconfigure matters. A robot locked into a crawler&#8217;s elongated profile cannot roll well, and a roller cannot leap. The printed architecture lets one physical object embody all three, selected in real time by external fields alone.</p>
<p>The researchers also demonstrated environmental adaptation and targeted load-bearing delivery, pushing the robot across multiple terrain types and showing that it could carry a payload to a designated location. This is where the work connects to some of the most pressing applications in soft robotics. Machines that must operate in unstructured and confined environments, such as the inside of industrial piping, disaster rubble, or the digestive tract, face constantly changing conditions. A rigid robot tuned for one environment fails in another. A soft robot that can flatten to pass a constriction, then roll briskly across an open chamber, then hop over a lip, addresses that variability with a single, untethered platform driven only by fields that penetrate deeply into the body without wires or batteries.</p>
<p>The significance of the non-contact aspect deserves emphasis. Many shape-changing robots rely on embedded heaters, pneumatic channels, or cables to trigger reconfiguration, all of which require either tethering to external equipment or complex onboard hardware. The Jilin-led team&#8217;s approach uses only magnetic fields, which pass through the material without physical connection. High-frequency fields for heating and low-frequency fields for actuation can be generated by external coil systems, meaning the robot itself carries no electronics at all. That simplicity translates into durability and miniaturization potential, since there is nothing onboard to break, seal, or power, and it opens a path toward robots small enough for biomedical use where batteries and wiring are impractical.</p>
<p>From a materials science standpoint, the study also showcases how direct ink writing expands design freedom in soft robotics. Conventional soft robot fabrication, often based on molding and soft lithography, struggles to place multiple functional materials with fine spatial control inside a single compliant body. Extrusion printing solves this by letting the designer choose, voxel by voxel along each printed line, whether a given region is elastic, magnetically responsive, or heat-generating, and how the magnetization directions and particle concentrations are graded across the structure. The result is a dual polymer matrix architecture in which mechanics and function are co-designed, a philosophy increasingly seen as the future of multifunctional soft machines. The monolithic multi-material body also avoids delamination failure modes that plague glued or bonded assemblies of dissimilar soft materials.</p>
<p>The work was carried out at the Key Laboratory of Bionic Engineering of the Ministry of Education at Jilin University, with Yumeng Han, Lu Zhang, and Xueli Zhou contributing equally as lead authors, alongside Qingping Liu, Luquan Ren, Chao Xu, and Liang He of the Institute of Biomedical Engineering at the University of Oxford. The research was supported by the National Natural Science Foundation of China, the Department of Science and Technology of Jilin Province, and the 10th CAST Young Elite Scientists Sponsorship Program. The team reports no competing interests, and the article is published open access, with extensive supplementary video material documenting the robot&#8217;s crawling, rolling, jumping, and payload-carrying maneuvers.</p>
<p>What comes next is the question that inevitably follows a demonstration like this. The dual-field magnetic strategy scales conceptually to smaller length scales, where magnetic actuation is already the method of choice for millimeter-scale medical robots, and the shape memory locking mechanism solves one of the field&#8217;s chronic problems, which is that soft robots typically need continuous field input merely to hold a pose. If future versions can reconfigure among even more modes, sense their surroundings, and do so at clinical scales, the printed morphing body demonstrated here could become a blueprint for a generation of untethered machines that change their bodies the way animals do, adapting their form to the task at hand while never stopping to make the change.</p>
<p><strong>Subject of Research:</strong> Direct ink writing of multi-material soft polymer matrices for magnetically actuated, shape-morphing soft robots</p>
<p><strong>Article Title:</strong> Direct ink writing of soft polymer matrices enables on-the-fly shape morphing in soft robots</p>
<p><strong>Article References:</strong> Han, Y., Zhang, L., Zhou, X., Liu, Q., Ren, L., Xu, C., &amp; He, L. (2026). Direct ink writing of soft polymer matrices enables on-the-fly shape morphing in soft robots. <em>Advanced Composites and Hybrid Materials</em>. <a href="https://doi.org/10.1007/s42114-026-02078-x" rel="noopener noreferrer">https://doi.org/10.1007/s42114-026-02078-x</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1007/s42114-026-02078-x" rel="noopener noreferrer">10.1007/s42114-026-02078-x</a></p>
<p><strong>Keywords:</strong> soft robotics, direct ink writing, shape memory polymers, magnetic actuation, NdFeB particles, Fe3O4 particles, shape morphing, dual magnetic fields, multi-material 3D printing, locomotion modes, bioinspired robotics, smart materials</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">208579</post-id>	</item>
	</channel>
</rss>
