<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>MRI acceleration &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/mri-acceleration/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Sun, 13 Sep 2026 00:12:51 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>MRI acceleration &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>Deep Learning Cuts Brain MRI Scans to Under 100 Seconds in Feasibility Trial</title>
		<link>https://scienmag.com/deep-learning-cuts-brain-mri-scans-to-under-100-seconds-in-feasibility-trial/</link>
		
		<dc:creator><![CDATA[Cassandra Pierce]]></dc:creator>
		<pubDate>Sun, 13 Sep 2026 00:12:51 +0000</pubDate>
				<category><![CDATA[Medicine]]></category>
		<category><![CDATA[BMC Medical Imaging]]></category>
		<category><![CDATA[brain MRI]]></category>
		<category><![CDATA[brain tumor detection MRI]]></category>
		<category><![CDATA[clinical feasibility of accelerated MRI]]></category>
		<category><![CDATA[deep learning]]></category>
		<category><![CDATA[Deep Learning in Radiology]]></category>
		<category><![CDATA[deep learning MRI acceleration]]></category>
		<category><![CDATA[deep learning reconstruction in medical imaging]]></category>
		<category><![CDATA[DEPICTA]]></category>
		<category><![CDATA[DEPICTA deep-learning technique]]></category>
		<category><![CDATA[diffusion-weighted imaging]]></category>
		<category><![CDATA[echo-planar imaging]]></category>
		<category><![CDATA[EPI-based MRI scan speed]]></category>
		<category><![CDATA[Huashan Hospital]]></category>
		<category><![CDATA[image reconstruction]]></category>
		<category><![CDATA[Medical Imaging]]></category>
		<category><![CDATA[motion artifacts in MRI]]></category>
		<category><![CDATA[MRI acceleration]]></category>
		<category><![CDATA[multi-contrast MRI sequences]]></category>
		<category><![CDATA[radiology]]></category>
		<category><![CDATA[rapid brain MRI imaging]]></category>
		<category><![CDATA[time-efficient neuroimaging]]></category>
		<category><![CDATA[ultra-fast multi-contrast brain MRI]]></category>
		<category><![CDATA[ultrafast MRI]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=199932</guid>

					<description><![CDATA[A prospective study of 124 patients found that a deep learning reconstruction technique called DEPICTA can complete a multi-contrast brain MRI in 87 seconds with clinically sufficient image quality.]]></description>
										<content:encoded><![CDATA[<p>Magnetic resonance imaging has long been the gold standard for peering into the human brain, but it has always demanded one precious commodity that many patients simply cannot spare: time. A conventional multi-contrast brain MRI examination can stretch well beyond ten minutes of table time, during which patients must lie motionless inside the bore of a humming magnet while the scanner harvests the faint magnetic signals that will become diagnostic images. Every extra second is an invitation for motion—a twitch, a swallow, a tremor—that can blur anatomy and obscure pathology. Now, a prospective feasibility study from Huashan Hospital of Fudan University in Shanghai reports that a deep-learning-driven acquisition technique called DEPICTA can compress a full multi-contrast brain MRI into just 87 seconds, and that the resulting images are good enough to be clinically meaningful.</p>
<p>The technique, whose full name is Deep-learning Enabled Precise Imaging via multi-Contrast multi-shoT EPI for Accelerated head scan, was evaluated in a study published in BMC Medical Imaging. Rather than accelerating only a single imaging sequence, DEPICTA uses an echo-planar imaging, or EPI, framework combined with deep learning reconstruction to deliver multiple clinically important contrast weightings—T1-FLAIR, T2-weighted, T2-FLAIR, and diffusion-weighted imaging—within a single ultrafast session. EPI is one of the fastest acquisition strategies available to MRI physicists because it collects an entire two-dimensional image from a single excitation, but it has historically suffered from geometric distortion and blurring. The innovation of DEPICTA lies in pairing a multi-shot EPI readout with neural-network-based reconstruction that fills in the missing spatial and contrast information left by aggressive undersampling of the raw data.</p>
<p>The study enrolled 124 consecutive patients who presented with a clinical indication for brain MRI between August and September 2025. Each participant underwent both a conventional brain MRI protocol and the ultrafast DEPICTA examination, allowing the researchers to compare the two approaches head to head in the same individuals. The cohort had a mean age of 49 years with a standard deviation of 22, and comprised 64 men and 60 women—a spread of ages and indications that the investigators argue reflects the reality of a working radiology department rather than the idealized conditions of a laboratory study. Because the design was prospective, the DEPICTA acquisition was planned in advance rather than applied retrospectively to archived scans, which strengthens the claim that the results are achievable in routine clinical practice.</p>
<p>The headline result is deceptively simple: DEPICTA achieved a total acquisition time of 1 minute and 27 seconds for the multi-contrast brain examination. That figure places the entire scan comfortably within the 100-second threshold set by the study title and represents a dramatic compression relative to conventional protocols, which typically allocate several minutes to each individual contrast sequence. In the ultrafast framework, the multi-shot EPI readout gathers data from multiple contrasts in a coordinated fashion, and the deep learning reconstruction model, trained to recognize the relationship between undersampled and fully sampled data, synthesizes images that would otherwise be unattainable at such speed. The significance is not merely convenience. Shorter scans reduce motion artifacts, ease the burden on claustrophobic or uncooperative patients, and open the door to MRI for populations—such as critically ill patients in intensive care units, confused elderly patients, or restless children—for whom prolonged examinations have been impractical or impossible.</p>
<p>Of course, speed alone is worthless if the images cannot be trusted, so the investigators subjected the ultrafast scans to rigorous qualitative and quantitative scrutiny. Two neuroradiologists independently scored overall image quality, gray-white matter differentiation, and the presence of artifacts, without knowledge of each other&#8217;s assessments. Their verdicts were nuanced. On overall image quality and gray-white matter differentiation, the ultrafast scans scored lower than conventional MRI—an expected consequence of aggressive acceleration—but remained in the range the study characterized as sufficient for clinical use. In other words, the deep learning reconstructions traded a measure of fine tissue contrast for a massive gain in acquisition speed, yet the images still delivered the diagnostic fundamentals that radiologists need.</p>
<p>Notably, on two crucial dimensions the ultrafast technique actually outperformed the conventional protocol. DEPICTA images showed fewer artifacts and higher signal-to-noise ratio on both T1-FLAIR and diffusion-weighted imaging compared with their conventional counterparts, differences that reached statistical significance at P &lt; 0.05. This finding is arguably the most surprising of the study. Diffusion-weighted imaging, which is indispensable for detecting acute stroke, is exquisitely sensitive to motion, and the conventional acquisition of DWI is a frequent casualty of patient movement. By collapsing the acquisition window to seconds and using learned reconstruction to suppress noise, the ultrafast approach produced cleaner, sharper diffusion images precisely where conventional MRI is most fragile. Higher signal-to-noise ratio means the deep learning reconstruction is not merely hallucinating plausible anatomy; it is consolidating genuine signal into images that rival, and in some respects exceed, those built from far more data.</p>
<p>Beyond radiologists&#8217; subjective impressions, the team examined whether measurements taken from ultrafast images could be trusted as surrogate quantities for clinical decision-making. They measured lesion sizes, apparent diffusion coefficient values within lesions—a quantitative marker of water diffusion used to characterize stroke and tumors—and the widths of the lateral, third, and fourth ventricles, which serve as indirect indicators of intracranial pressure and hydrocephalus. The ultrafast measurements agreed well with those from conventional MRI for lesion size, lesion ADC, and the width of the lateral and third ventricles, demonstrating the quantitative comparability that regulators and clinicians would require before adopting such a technique for serial monitoring. The one exception was the width of the fourth ventricle, where the two methods diverged significantly, with a P value of 0.006. The authors note this single discordance as an honest limitation, likely attributable to the small size of the fourth ventricle and the resolution constraints of the accelerated acquisition in that region.</p>
<p>The study also included a T2*-weighted and susceptibility-weighted module in the DEPICTA protocol, which offers the potential to detect microbleeds and venous abnormalities. However, the researchers explicitly excluded this module from their comparative image-quality and quantitative analyses, framing the full multi-contrast capability as promising but not yet validated at the level of the other sequences. That methodological restraint signals a careful, staged approach: the team is claiming feasibility for the validated contrasts while flagging the more exotic components of the protocol for future evaluation. It is a reminder that in medical imaging, enthusiasm must always be tempered by the discipline of head-to-head validation against the established standard.</p>
<p>The implications of the study extend well beyond Huashan Hospital. If a complete multi-contrast brain MRI can be delivered in under 90 seconds, the economics of neuroimaging begin to change. Scanner throughput could increase substantially, shortening waiting lists in overburdened health systems. Emergency departments could integrate near-instant brain MRI into acute stroke pathways, where every minute of delayed diagnosis translates into lost neurons. Patients in intensive care units, who currently must often be transported with ventilators and monitoring equipment into the magnet room for lengthy scans, could be imaged with less physiological risk. And populations historically excluded from MRI—patients with dementia who cannot follow instructions, young children who would otherwise require sedation—become plausible candidates for high-quality imaging because even brief cooperation is enough. The deep learning reconstruction also carries challenges of its own, since neural networks can introduce subtle biases and must be validated across diverse populations, scanner vendors, and disease spectra before widespread deployment.</p>
<p>The research was approved by the ethical board of Huashan Hospital, Fudan University, conducted with written informed consent, and adhered to the Declaration of Helsinki. It was supported by the National Natural Science Foundation of China under grant 82271966 and the Explorers Program of Shanghai under grant 24TS1410800. The corresponding authors are Yiping Lu and Bo Yin of the Department of Radiology at Huashan Hospital, and the study was a collaboration among co-first authors Mengdi Gao, Nan Mei, Jie Qin, Qirui Fu, and Xuanxuan Li, alongside Jing Du, Ke Sun, and Yiping Lu. Published open access, the work invites replication at other centers—a necessary step before an 87-second brain MRI moves from feasibility study to daily practice. For now, the message is clear: the era of the hundred-second brain scan is no longer hypothetical, and it has been delivered not by a bigger magnet but by an algorithm that knows what to do with less.</p>
<p><strong>Subject of Research:</strong> Prospective feasibility of deep learning reconstructed ultrafast multi-contrast brain MRI completed within 100 seconds</p>
<p><strong>Article Title:</strong> Ultrafast brain MRI within 100 s based on deep learning reconstruction: a prospective feasibility study</p>
<p><strong>Article References:</strong> Ultrafast brain MRI within 100 s based on deep learning reconstruction: a prospective feasibility study. (n.d.). <a href="https://doi.org/10.1186/s12880-026-02778-2" rel="noopener noreferrer">https://doi.org/10.1186/s12880-026-02778-2</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1186/s12880-026-02778-2" rel="noopener noreferrer">10.1186/s12880-026-02778-2</a></p>
<p><strong>Keywords:</strong> brain MRI, deep learning, ultrafast MRI, DEPICTA, echo-planar imaging, image reconstruction, BMC Medical Imaging, diffusion-weighted imaging, radiology, medical imaging, Huashan Hospital, MRI acceleration</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">199932</post-id>	</item>
	</channel>
</rss>
