<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>molecularly imprinted polymer &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/molecularly-imprinted-polymer/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Thu, 15 Oct 2026 13:15:20 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>molecularly imprinted polymer &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>Molecularly Imprinted Sensor Promises Faster Quality Control for Lutein Products</title>
		<link>https://scienmag.com/molecularly-imprinted-sensor-promises-faster-quality-control-for-lutein-products/</link>
		
		<dc:creator><![CDATA[Bethany Barker]]></dc:creator>
		<pubDate>Thu, 15 Oct 2026 13:15:20 +0000</pubDate>
				<category><![CDATA[Chemistry]]></category>
		<category><![CDATA[analytical chemistry]]></category>
		<category><![CDATA[biosensors for dietary supplement testing]]></category>
		<category><![CDATA[carotenoid ester quantification]]></category>
		<category><![CDATA[carotenoids]]></category>
		<category><![CDATA[challenges in lutein ester analysis]]></category>
		<category><![CDATA[chemical sensing in food safety]]></category>
		<category><![CDATA[conversion factor]]></category>
		<category><![CDATA[dietary supplements]]></category>
		<category><![CDATA[electrochemical sensor]]></category>
		<category><![CDATA[ester bond detection in carotenoids]]></category>
		<category><![CDATA[innovative analytical techniques in life sciences]]></category>
		<category><![CDATA[lutein]]></category>
		<category><![CDATA[lutein esters]]></category>
		<category><![CDATA[lutein measurement]]></category>
		<category><![CDATA[marigold extract]]></category>
		<category><![CDATA[marigold extract analysis]]></category>
		<category><![CDATA[mathematical conversion in chemical analysis]]></category>
		<category><![CDATA[metal-organic framework]]></category>
		<category><![CDATA[molecularly imprinted electrochemical sensors]]></category>
		<category><![CDATA[molecularly imprinted polymer]]></category>
		<category><![CDATA[plant-based lutein extraction methods]]></category>
		<category><![CDATA[quality control]]></category>
		<category><![CDATA[rapid quality control in food supplements]]></category>
		<category><![CDATA[saponification]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=274607</guid>

					<description><![CDATA[A molecularly imprinted electrochemical sensor paired with a conversion factor strategy can rapidly estimate four major lutein esters in marigold extracts, offering a faster alternative to saponification-based quality control.]]></description>
										<content:encoded><![CDATA[<p>Marigold petals have long been the world&#8217;s commercial workhorse for producing lutein, the golden carotenoid that accumulates in the human retina and is increasingly added to foods, beverages, animal feed, and dietary supplements. Yet behind every bottle of eye-care capsules lies a stubborn analytical bottleneck: in the plant, lutein does not exist as a free molecule but as a family of fatty-acid esters that chemists must typically break apart before they can measure anything. A research team at the Beijing Institute of Technology, led by Axin Liang, now reports a sensing platform that sidesteps much of that labor, combining a molecularly imprinted electrochemical sensor with a mathematical conversion strategy to estimate the four dominant lutein esters in marigold extracts from a single direct measurement. The study was published in the open-access journal Engineering in Life Sciences on 24 August 2026.</p>
<p>The conventional workflow that the new method challenges is worth understanding, because it explains why quality-control laboratories have been eager for alternatives. To quantify lutein in marigold material, analysts generally perform saponification, a reaction that hydrolyzes the ester bonds and converts the esters into free lutein, which can then be separated and measured chromatographically. Saponification requires heating, consumes considerable time, and introduces a real risk of degrading heat-sensitive carotenoids, molecules that are notoriously fragile in the presence of elevated temperatures, oxygen, and light. Laboratories that instead try to quantify each lutein ester directly by chromatography face a different obstacle: individual lutein ester reference standards are scarce and expensive, and running complete calibrations for every ester in every batch quickly becomes cost-prohibitive for routine industrial screening.</p>
<p>The Beijing team&#8217;s answer rests on two complementary ideas. The first is analytical: rather than measuring every ester separately, measure one representative ester accurately and calculate the others from stable, predefined conversion factors. The second is electrochemical: build a sensor that can detect that representative ester quickly, selectively, and without the elaborate sample preparation that chromatography demands. Together, the two components form what the researchers describe as a sensing-conversion platform, one that links a physical measurement to a set of well-characterized mathematical relationships that translate a single signal into a profile of four compounds.</p>
<p>Before building the sensor, the researchers needed to know exactly what they were dealing with in real marigold extracts. Using high-performance liquid chromatography coupled with mass spectrometry, they characterized the lutein ester composition of their samples and identified four predominant compounds: lutein dimyristate, lutein myristate-palmitate, lutein dipalmitate, and lutein palmitate-stearate. These differ in which fatty acids are esterified to the lutein backbone, and therefore in molecular mass and chromatographic behavior, but they travel through the extract chemistry as a tightly related family. The team selected lutein dipalmitate as the reference marker for direct detection and derived conversion factors for the other three esters from chromatographic peak areas and molecular masses.</p>
<p>The conversion factors themselves proved remarkably stable, which is the linchpin of the whole approach. For lutein dimyristate the factor was 0.903, for lutein myristate-palmitate it was 0.964, and for lutein palmitate-stearate it was 1.035. When the team repeated the determinations across different injection volumes, the relative standard deviations stayed below 1 percent. Robustness testing that varied instruments, chromatographic columns, temperatures, and flow rates generally produced values below 2 percent. In practical terms, this means the conversion relationships are not an artifact of one particular machine or one particular day; they behave as genuine physicochemical properties of the ester family, which is exactly what a quality-control laboratory needs if it is to trust indirect calculations in routine work.</p>
<p>With the conversion framework in place, the challenge became detecting lutein dipalmitate rapidly and selectively. The team synthesized a conductive metal-organic framework, Ni₃(HITP)₂, a coordination material known for its electrical conductivity and high surface area, and deposited it onto a screen-printed carbon electrode. On top of this conductive layer they grew a molecularly imprinted polymer film in the presence of lutein dipalmitate, the template molecule. Once the template was removed, the polymer retained complementary recognition cavities shaped to rebind lutein dipalmitate selectively, much as an antibody binds its antigen but with the chemical robustness of a synthetic material. Structural and electrochemical analyses confirmed successful fabrication, and the metal-organic framework boosted the electrode&#8217;s peak current approximately fourfold relative to an unmodified electrode, a substantial gain in signal that underpins the sensor&#8217;s sensitivity.</p>
<p>The optimized operating conditions reflect careful tuning of the imprinting and detection steps. The researchers settled on twelve electropolymerization cycles to build the polymer film, a scan rate of 50 millivolts per second, four minutes of template removal, and fifteen minutes of target rebinding before each measurement. Under these conditions the sensor responded linearly across a lutein dipalmitate concentration range of 0.01 to 100 micromolar and achieved a detection limit of 8.20 nanomolar, a very low threshold for an electrochemical device applied to complex plant extracts. Selectivity testing showed substantially greater sensitivity toward lutein dipalmitate than toward free lutein, α-tocopherol, glucose, or glutamic acid, molecules that might plausibly accompany the target in real samples and interfere with a less discriminating sensor.</p>
<p>The most convincing evidence for any analytical method is how it performs on real samples, and here the platform delivered results that closely tracked the conventional approach. Applied to marigold extract, the new sensing-conversion method estimated lutein content at 62.63 milligrams per gram, compared with 71.73 milligrams per gram obtained through conventional saponification. For a commercial eye-care product, the corresponding figures were 3.60 and 3.72 milligrams per gram, an agreement tight enough to suggest the method can stand in for slower workflows in practical screening. The residual gap on the marigold extract likely reflects the complexity of the raw plant matrix, but the commercial product result demonstrates that the platform can handle finished formulations where accuracy matters most to manufacturers and regulators.</p>
<p>The broader significance of the work lies in what it removes from the analytical pipeline. By eliminating saponification, the method simplifies sample preparation, shortens analysis time, and avoids the thermal degradation that threatens carotenoids. By relying on a single directly measured marker plus conversion factors, it reduces dependence on multiple expensive lutein ester standards that many laboratories cannot readily obtain. And by using a screen-printed electrode modified with a conductive metal-organic framework, it points toward low-cost, disposable sensor formats that could migrate from research benches into factory quality-control lines, where decisions about batches of marigold extract, dietary supplements, and eye-care products must be made quickly and repeatedly.</p>
<p>The authors are candid about the limits of the platform. Further validation will be needed for samples whose ester profiles differ substantially from marigold, or that contain high levels of minor lutein esters not covered by the four predominant compounds characterized here. Conversion factors derived from one botanical matrix cannot simply be assumed to hold for every natural product, and laboratories adopting the method will need to confirm that their own materials fall within the range where the four-ester model applies. Still, the study provides a promising foundation for rapid screening, industrial monitoring, and routine quality assessment of lutein-containing natural products, and it illustrates a broader trend in analytical chemistry: replacing laborious, standards-hungry chromatographic workflows with selective sensors paired with robust mathematical relationships. For an industry built on a pigment that protects the human retina, faster and cheaper verification of what is actually in the bottle is a development worth watching. The work was supported by the National Key Research and Development Program of China, the Fundamental Research Funds for the Central Universities, the Beijing Institute of Technology Research Fund Program for Young Scholars, and a Scientific Research Cooperation Program grant, and the authors declare no competing interests.</p>
<p><strong>Subject of Research:</strong> A molecularly imprinted electrochemical sensor with a conversion factor strategy for rapid quantification of lutein esters in marigold extracts</p>
<p><strong>Article Title:</strong> Rapid sensor streamlines quality control of lutein-rich products</p>
<p><strong>Article References:</strong> Rapid sensor streamlines quality control of lutein-rich products. (n.d.). <a href="https://www.eurekalert.org/news-releases/1147725" rel="noopener noreferrer">Original publication</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> Not provided</p>
<p><strong>Keywords:</strong> lutein, lutein esters, marigold extract, molecularly imprinted polymer, electrochemical sensor, metal-organic framework, quality control, carotenoids, dietary supplements, conversion factor, saponification, analytical chemistry</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">274607</post-id>	</item>
		<item>
		<title>Molecularly Imprinted Polymer With Core-Shell Design Enables Ultrasensitive Detection of Bisphenol-A in Water</title>
		<link>https://scienmag.com/molecularly-imprinted-polymer-with-core-shell-design-enables-ultrasensitive-detection-of-bisphenol-a-in-water/</link>
		
		<dc:creator><![CDATA[Neil Sanderson]]></dc:creator>
		<pubDate>Sat, 03 Oct 2026 17:21:08 +0000</pubDate>
				<category><![CDATA[Chemistry]]></category>
		<category><![CDATA[adsorption]]></category>
		<category><![CDATA[bisphenol A]]></category>
		<category><![CDATA[co-precipitation polymerization]]></category>
		<category><![CDATA[core-shell]]></category>
		<category><![CDATA[core-shell design]]></category>
		<category><![CDATA[endocrine disruptor]]></category>
		<category><![CDATA[endocrine disruptor detection]]></category>
		<category><![CDATA[Environmental Monitoring]]></category>
		<category><![CDATA[environmental water analysis]]></category>
		<category><![CDATA[Langmuir isotherm]]></category>
		<category><![CDATA[molecularly imprinted polymer]]></category>
		<category><![CDATA[nanogram-level detection limit]]></category>
		<category><![CDATA[plastic shell polymerization]]></category>
		<category><![CDATA[polymer-based sensors]]></category>
		<category><![CDATA[selective adsorption for bisphenol-A]]></category>
		<category><![CDATA[solid-phase extraction]]></category>
		<category><![CDATA[spectrophotometric analysis]]></category>
		<category><![CDATA[spectrophotometry]]></category>
		<category><![CDATA[ultrasensitive BPA detection]]></category>
		<category><![CDATA[UV-Vis spectroscopy]]></category>
		<category><![CDATA[water analysis]]></category>
		<category><![CDATA[water contamination monitoring]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=231086</guid>

					<description><![CDATA[Researchers have developed a core-shell molecularly imprinted polymer for solid-phase extraction that detects bisphenol-A in environmental waters at sub-nanogram-per-liter levels using affordable spectrophotometry.]]></description>
										<content:encoded><![CDATA[<p>A team of analytical chemists has unveiled a new core-shell molecularly imprinted polymer that can fish out vanishingly small traces of bisphenol-A (BPA) from environmental waters and deliver a reading with a simple spectrophotometer. The study, published in Polymer Bulletin by Muhammad Saqaf Jagirani, Aamna Balouch, Ikramullah Jagirani and Aftab Hussain Khuhawar, describes a facile co-precipitation polymerization route that builds a selective plastic shell around a supporting core, creating an adsorbent purpose-made for one molecule. When coupled to solid-phase extraction and UV/Vis spectroscopy, the material achieved a detection limit of 0.98 nanograms per liter, a level of sensitivity that places the method among the most accessible tools yet proposed for routine BPA monitoring.</p>
<p>BPA is one of the highest-volume industrial chemicals on the planet and the building block of polycarbonate plastics and epoxy resins. It lines food and beverage cans, coats water pipes, and forms part of thermal paper receipts, which means human exposure is effectively continuous. The concern is not acute poisoning but endocrine disruption: BPA mimics estrogenic hormones at very low concentrations, and systematic reviews have linked chronic exposure to metabolic disorders, reproductive dysfunction and other health effects. In 2023, the European Food Safety Authority re-evaluated the risks of BPA in foodstuffs and dramatically tightened its tolerable daily intake, underscoring how seriously regulators now treat this ubiquitous compound. Because BPA leaches from containers and products into water systems, environmental monitoring demands methods that can detect it at parts-per-trillion levels, not merely parts per billion.</p>
<p>The analytical challenge is twofold. First, real environmental samples are messy: BPA coexists with phenolic relatives, dissolved organic matter and salts that can swamp a detector. Second, the gold-standard instruments for trace BPA analysis, such as liquid chromatography coupled to mass spectrometry, are expensive, require skilled operators and are often unavailable in the laboratories of developing regions where water quality problems are most acute. Spectrophotometry, by contrast, is cheap, robust and found in nearly every teaching and municipal lab, but on its own it lacks the selectivity and sensitivity to pick a single endocrine disruptor out of a complex matrix. The new study addresses both problems at once by pairing a highly selective extraction material with an affordable optical readout.</p>
<p>The heart of the method is molecular imprinting, sometimes described as building a plastic mold around a molecule. The researchers polymerized functional monomers in the presence of BPA itself, so that as the polymer network hardened, cavities formed that were complementary to the template in size, shape and chemical functionality. After the template was leached out, the polymer was left with recognition sites that preferentially rebind BPA over structurally similar compounds, behaving like artificial antibodies but with far greater chemical and thermal stability. The team chose a core-shell architecture: a solid core provides mechanical integrity and a large surface area, while a thin imprinted shell places the recognition cavities close to the surface, where analyte molecules can reach them quickly rather than diffusing through a dense polymer bulk.</p>
<p>Synthesis proceeded by co-precipitation polymerization, a straightforward route that avoids elaborate equipment and yields particles suitable for packing into extraction cartridges. The material was characterized with Fourier-transform infrared spectroscopy, which confirmed the functional groups responsible for binding, and field-emission scanning electron microscopy, which revealed the morphology of the imprinted particles. UV/Vis spectroscopy served both to track template removal and, ultimately, to quantify BPA after extraction. The simplicity of this characterization and workflow is part of the appeal: the entire pipeline from sample to number can run on instruments that cost a small fraction of a mass spectrometer.</p>
<p>Performance optimization followed the classic levers of adsorption chemistry. The researchers systematically varied pH, contact time, adsorbent dose and shaking speed to maximize uptake. The optimum emerged at pH 6, close to the neutral conditions of most natural waters, which is convenient for direct application to real samples. Under these conditions the polymer reached a maximum adsorption capacity of 112.35 milligrams of BPA per gram of material, a figure that reflects both the density of imprinted cavities and the accessibility afforded by the core-shell geometry. Kinetic analysis showed that adsorption follows a pseudo-second-order model, meaning the rate-limiting step is the chemical interaction between BPA and its binding sites rather than simple diffusion, while equilibrium data fit the Langmuir isotherm, indicating uniform, monolayer-type binding onto a finite set of equivalent sites.</p>
<p>The selectivity results are perhaps the most striking. When the polymer was challenged with coexisting molecules that resemble BPA, the relative selectivity factors came out below one, confirming that the imprinted cavities genuinely discriminate in favor of their template. This matters enormously in practice, because environmental waters contain bisphenol analogs and phenolic compounds whose signals would otherwise interfere. The calibration curve was linear across 2 to 10 micrograms per liter after preconcentration by solid-phase extraction, and the limits of detection and quantification were 0.98 nanograms per liter and 329.5 nanograms per liter respectively. Those numbers mean the method can confidently flag BPA at concentrations relevant to regulatory and toxicological thresholds, using an optical detector rather than a mass spectrometer.</p>
<p>To prove the method works outside the laboratory, the team applied it to real environmental samples, and the technique performed successfully, recovering BPA from the complex matrices that typically defeat less selective adsorbents. The combination of a selective imprinted polymer, a simple solid-phase extraction step and conventional spectrophotometric detection creates a workflow that municipal water utilities, university teaching labs and field stations in resource-limited settings could realistically adopt. It also aligns with a broader movement in separation science toward greener, more affordable analytical chemistry, in which molecularly imprinted materials are increasingly promoted as sustainable alternatives to solvent-intensive extractions and instrument-heavy confirmatory methods.</p>
<p>The work also fits into a fast-growing literature on core-shell imprinted particles, which have been used for everything from extracting BPA from milk to sensing proteins and detecting veterinary drug residues. By keeping the imprinted layer thin, the core-shell design solves the chronic weakness of conventional bulk-imprinted polymers, in which many recognition sites are buried so deep that analytes cannot reach them, wasting capacity and slowing equilibration. The new study demonstrates that a facile co-precipitation synthesis, rather than a complex multistep fabrication, is enough to capture those benefits for environmental monitoring.</p>
<p>For the public, the significance is straightforward: the plastics that make modern life convenient shed a hormone-mimicking chemical into water at concentrations that are difficult to measure but increasingly regulated. Tools like this core-shell imprinted polymer make it possible for far more laboratories to find out exactly how much BPA is in a river, a reservoir or a tap, at a fraction of the usual cost. If such methods spread, the data they generate could sharpen exposure assessments, support enforcement of tightened safety limits, and ultimately push manufacturers toward safer alternatives. The study, published in Polymer Bulletin, shows that sometimes the path to ultrasensitive detection is not a more expensive instrument but a smarter piece of plastic designed to recognize a single molecule.</p>
<p><strong>Subject of Research:</strong> Development of a core-shell molecularly imprinted polymer for ultrasensitive solid-phase extraction and spectrophotometric detection of bisphenol-A in environmental samples</p>
<p><strong>Article Title:</strong> High-performance core-shell designed molecularly imprinted polymer solid-phase extraction for ultrasensitive spectrophotometric monitoring of bisphenol-A</p>
<p><strong>Article References:</strong> Jagirani, M. S., Balouch, A., Jagirani, I., &amp; Khuhawar, A. H. (2026). High-performance core-shell designed molecularly imprinted polymer solid-phase extraction for ultrasensitive spectrophotometric monitoring of bisphenol-A. <em>Polymer Bulletin, 83</em>(11), Article 635. <a href="https://doi.org/10.1007/s00289-026-06686-x" rel="noopener noreferrer">https://doi.org/10.1007/s00289-026-06686-x</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1007/s00289-026-06686-x" rel="noopener noreferrer">10.1007/s00289-026-06686-x</a></p>
<p><strong>Keywords:</strong> bisphenol-A, molecularly imprinted polymer, core-shell, solid-phase extraction, spectrophotometry, endocrine disruptor, water analysis, adsorption, Langmuir isotherm, environmental monitoring, co-precipitation polymerization, UV/Vis spectroscopy</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">231086</post-id>	</item>
	</channel>
</rss>
