<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>medical knowledge graph &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/medical-knowledge-graph/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Tue, 20 Oct 2026 16:37:28 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>medical knowledge graph &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>HalluciGuard-Eye Cuts Hallucinations in Ophthalmic AI Benchmarks</title>
		<link>https://scienmag.com/halluciguard-eye-cuts-hallucinations-in-ophthalmic-ai-benchmarks/</link>
		
		<dc:creator><![CDATA[Ophelia Keating]]></dc:creator>
		<pubDate>Tue, 20 Oct 2026 16:37:28 +0000</pubDate>
				<category><![CDATA[Science News]]></category>
		<category><![CDATA[clinical factuality]]></category>
		<category><![CDATA[diabetic retinopathy]]></category>
		<category><![CDATA[dual-stream multimodal AI architecture]]></category>
		<category><![CDATA[fundus photograph diagnostic accuracy]]></category>
		<category><![CDATA[fundus photography]]></category>
		<category><![CDATA[HalluciGuard-eye]]></category>
		<category><![CDATA[hallucination detection]]></category>
		<category><![CDATA[hierarchical factuality assessment in medical imaging]]></category>
		<category><![CDATA[Knowledge]]></category>
		<category><![CDATA[knowledge graphs]]></category>
		<category><![CDATA[knowledge-grounded AI in eye health]]></category>
		<category><![CDATA[medical knowledge graph]]></category>
		<category><![CDATA[multimodal AI ophthalmology]]></category>
		<category><![CDATA[multimodal language models]]></category>
		<category><![CDATA[ophthalmic artificial intelligence]]></category>
		<category><![CDATA[optical coherence tomography]]></category>
		<category><![CDATA[optical coherence tomography AI system]]></category>
		<category><![CDATA[reducing hallucinations in ophthalmic AI benchmarks]]></category>
		<category><![CDATA[retinal-image analysis hallucination reduction]]></category>
		<category><![CDATA[retrieval-augmented generation]]></category>
		<category><![CDATA[retrieval-augmented generation in ophthalmology]]></category>
		<category><![CDATA[retrospective cohort]]></category>
		<category><![CDATA[structured medical knowledge graphs for diagnosis]]></category>
		<category><![CDATA[visual-semantic alignment in retinal scans]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=320074</guid>

					<description><![CDATA[In public-benchmark and retrospective evaluations, HalluciGuard-Eye reduced hallucinations in ophthalmic multimodal AI and maintained diabetic-retinopathy classification performance, without establishing patient-outcome benefits or unsupervised clinical readiness.]]></description>
										<content:encoded><![CDATA[<p>A knowledge-grounded multimodal artificial-intelligence system reduced hallucinations in retinal-image analysis while maintaining or improving diagnostic performance, according to evaluations of fundus photographs and optical coherence tomography scans. HalluciGuard-Eye combines a domain-specific medical knowledge graph with visual-semantic alignment, retrieval-augmented generation and hierarchical factuality assessment. On the EyePACS diabetic-retinopathy benchmark, the system produced a 22.2% hallucination rate, compared with 38.4% for the evaluated LLaVA-Med model, a relative reduction of 42.2%.</p>
<p>It also achieved 91.6% factual accuracy for clinical-entity recognition. These experimental results support the technical value of structured medical knowledge, but they do not establish improved patient outcomes or readiness for unsupervised clinical use. HalluciGuard-Eye was built on the LLaVA-1.5 architecture, using a ViT-L/14 vision encoder fine-tuned on fundus and OCT data and a Vicuna-13B language model.</p>
<p>Its dual-stream design separates two tasks that conventional multimodal language models may handle imperfectly: determining whether a statement corresponds to what is visible in an image and determining whether it agrees with established ophthalmic knowledge. The Visual-Semantic Alignment Module compares visual tokens with claim-level text through bidirectional attention and contrastive learning. Its visual representation retains patch-level details, quadrant-level context and a global token, allowing the system to evaluate small lesions, local vascular structures and the overall distribution of disease.</p>
<p>In an ablation study, removing this module increased the EyePACS hallucination rate from 22.2% to 26.6% and lowered the Hierarchical Factuality Score from 81.7 to 76.4. The largest gain from visual-semantic alignment occurred for small lesions: lesion F1 rose by 14.9 percentage points among lesions occupying less than 0.25% of an image, compared with a 5.6-point gain for lesions occupying at least 1%. The Clinical Factuality Grounding Network supplies the system with structured evidence about anatomical structures, pathology, diseases, symptoms, procedures and imaging findings.</p>
<p>The underlying Ophthalmic Clinical Knowledge Graph contains 47,832 entities and 156,294 semantic triplets, organized into hierarchical, causal, spatial and clinical relationships. Its sources include guidance from the American Academy of Ophthalmology, the European Society of Retina Specialists and the International Council of Ophthalmology, the ICD-11 classification, standardized diabetic-retinopathy and age-related eye-disease grading systems, and ophthalmology literature indexed in PubMed. Conflicting guidance is prioritized by the most recent applicable guideline, while unresolved conflicts are marked for senior-expert review rather than silently combined.</p>
<p>An independent stratified audit of 3,000 graph triplets found that 92.7% were supported, with a 95% confidence interval of 91.7% to 93.6%. The authors note that this estimate describes the audited sample rather than every edge in the graph. For each candidate response, HalluciGuard-Eye recognizes clinical entities, assigns greater retrieval weight to claims involving vision-threatening lesions or referral relationships, and searches relation-aware portions of the graph.</p>
<p>It then expands the retrieved subgraphs through multi-hop traversal before reranking candidate answers. The selected response is generated with a gated mechanism that combines language-model states with retrieved evidence during decoding. The researchers used a two-hop retrieval depth after a sensitivity analysis found that it offered the best balance between critical-evidence recall and hallucination rate.</p>
<p>Increasing the depth to four hops raised recall slightly, from 87.6% to 89.8%, but reduced the factuality score and increased latency. The graph was central to performance: removing it increased the EyePACS hallucination rate to 29.8% and lowered HFS to 72.3, a reduction of 9.4 points from the full system. Removing the Clinical Factuality Grounding Network produced an intermediate decline, with a 28.1% hallucination rate and an HFS of 74.8.</p>
<p>The system was evaluated on four public ophthalmic imaging datasets. EyePACS contained 35,126 labeled fundus photographs, including a 3,512-image test partition and a separately annotated subset of 1,500 images used for lesion-level assessment. Messidor-2 supplied 1,748 external fundus images without model fine-tuning, while OCTDL contained 2,064 OCT B-scans and the Kermany OCT dataset contained 84,484 images.</p>
<p>Comparisons included LLaVA-Med, Med-Flamingo, HuatuoGPT-Vision and Qwen-VL-Chat, as well as retrieval- and hallucination-focused systems including Self-RAG, V-RAG, MedRAG and MediHallDetector. On Kermany OCT, HalluciGuard-Eye recorded a 23.8% hallucination rate versus 41.2% for LLaVA-Med, again corresponding to a 42.2% relative reduction. For diabetic-retinopathy grading on EyePACS, it achieved 89.6% sensitivity and 92.1% specificity, exceeding MedRAG by 2.4 and 2.7 percentage points, respectively.</p>
<p>Its AUC was 0.951 and quadratic weighted kappa was 0.873. Five-seed testing produced low dispersion, with a hallucination rate of 22.2% plus or minus 0.5% and sensitivity of 89.6% plus or minus 0.4%. Retrieval tests indicated that the system’s gains came from combining the graph with claims about what mattered clinically.</p>
<p>Replacing an unweighted graph query with a salience-weighted, relation-aware query increased critical-evidence recall at 20 from 78.1% to 87.6% and evidence normalized discounted cumulative gain at 20 from 0.742 to 0.811. At the same time, the hallucination rate fell by 2.7 percentage points and HFS rose by 2.5 points. Recall for vision-threatening lesion claims rose from 74.3% to 88.1%.</p>
<p>Masking progressively larger portions of the graph produced a graded deterioration: when only 50% of critical relations were retained, critical-evidence recall declined to 71.0%, the hallucination rate rose to 28.9% and HFS fell to 75.4. This sensitivity analysis supports the graph’s contribution, but it also shows that HalluciGuard-Eye depends on the coverage and quality of its curated medical knowledge. Open-ended reports were assessed on 1,500 expert-annotated cases rather than reduced only to a disease label.</p>
<p>HalluciGuard-Eye reached 90.8% lesion-presence F1, 89.2% lesion-location accuracy, 86.7% severity accuracy, 92.6% negation F1, 86.1% hedging appropriateness and 91.4% clinical-entity F1. Its largest improvement over MedRAG was in severity accuracy, at 8.5 percentage points. The study’s Hierarchical Factuality Score separates reliability into anatomical accuracy, pathological characterization and validity of clinical recommendations.</p>
<p>HalluciGuard-Eye scored 86.4, 79.0 and 81.4 on those three components in EyePACS, producing a composite score of 81.7. Pathological characterization remained the weakest component for both the proposed system and its comparators. The ranking did not change when equal or anatomy-, pathology- or recommendation-heavy weights were applied, although the findings do not establish that the composite score is an externally validated measure of real-world safety.</p>
<p>A retrospective patient-clustered cohort offered a different test because it included both eyes from some participants and examined performance in a clinical collection rather than only a public test split. The analysis covered 512 patients and 928 eyes observed across four calendar years, with 33.8% prevalence of referable diabetic retinopathy. Model, retrieval corpus, prompts and thresholds were reportedly frozen before reference labels were finalized.</p>
<p>HalluciGuard-Eye achieved 88.9% sensitivity and 90.7% specificity for referable disease, with an AUC of 0.946 and a serious-hallucination rate of 8.5%. The corresponding MedRAG values were 85.0% sensitivity, 88.1% specificity, an AUC of 0.920 and a 14.4% serious-hallucination rate. The analysis accounted for correlation between fellow eyes through patient-clustered bootstrapping and generalized estimating equations.</p>
<p>Sensitivity was highest for high-quality images at 91.7%, compared with 88.9% for moderate-quality and 84.1% for low-quality images, illustrating that image quality remained an important influence. Human evaluations also favored the grounded system. Five board-certified ophthalmologists rated 200 responses from each method, assigning HalluciGuard-Eye the highest accuracy and clinical-trust scores.</p>
<p>In a separate crossover experiment, 24 ophthalmologists assessed 480 referral vignettes with and without model assistance. Assisted review increased referral sensitivity from 86.9% to 92.7% and specificity from 88.2% to 91.0%. Serious decision errors declined from 11.5% to 6.9%, while median reading time fell from 52 to 42 seconds.</p>
<p>These are experimental workflow results from a controlled vignette study, not evidence that deploying the system will improve real patient outcomes. The researchers also profiled the engineering burden: for a 256-token report, retrieval added 0.12 to 0.15 seconds, and four-bit inference on a 24-gigabyte Nvidia RTX 4090 produced a latency of 2.47 seconds per report. Overall, the study shows a technically coherent way to reduce fabricated claims and ground image interpretation in explicit clinical relationships, while leaving the prospective, multicenter and patient-outcome testing required for clinical deployment unresolved.</p>
<p><strong>Subject of Research:</strong> Benchmark and retrospective evaluation of knowledge-grounded hallucination detection in ophthalmic multimodal AI</p>
<p><strong>Article Title:</strong> HalluciGuard-eye: knowledge graph-enhanced retrieval-augmented generation for hallucination detection and mitigation in ophthalmic multimodal large language models</p>
<p><strong>Article References:</strong> Wu, G., Ai, C., &amp; Wu, W. (2026). HalluciGuard-eye: knowledge graph-enhanced retrieval-augmented generation for hallucination detection and mitigation in ophthalmic multimodal large language models. <em>Frontiers in Endocrinology, 17</em>, Article 1976190. <a href="https://doi.org/10.3389/fendo.2026.1976190" rel="noopener noreferrer">https://doi.org/10.3389/fendo.2026.1976190</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.3389/fendo.2026.1976190" rel="noopener noreferrer">10.3389/fendo.2026.1976190</a></p>
<p><strong>Keywords:</strong> ophthalmic artificial intelligence, multimodal language models, hallucination detection, diabetic retinopathy, knowledge graphs, retrieval-augmented generation, fundus photography, optical coherence tomography, clinical factuality, retrospective cohort, HalluciGuard-eye, knowledge</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">320074</post-id>	</item>
	</channel>
</rss>
