<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>longitudinal monitoring &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/longitudinal-monitoring/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Oct 2026 11:44:09 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.2</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>longitudinal monitoring &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>Blood Test and Scans Combined Reveal Hidden Patchiness in Advanced Melanoma</title>
		<link>https://scienmag.com/blood-test-and-scans-combined-reveal-hidden-patchiness-in-advanced-melanoma/</link>
		
		<dc:creator><![CDATA[Nathaniel Bowman]]></dc:creator>
		<pubDate>Fri, 02 Oct 2026 11:44:09 +0000</pubDate>
				<category><![CDATA[Medicine]]></category>
		<category><![CDATA[advanced melanoma]]></category>
		<category><![CDATA[biomarker]]></category>
		<category><![CDATA[blood tests for cancer]]></category>
		<category><![CDATA[circulating tumor DNA]]></category>
		<category><![CDATA[ctDNA]]></category>
		<category><![CDATA[imaging scans in melanoma]]></category>
		<category><![CDATA[immune checkpoint inhibitors]]></category>
		<category><![CDATA[liquid biopsy]]></category>
		<category><![CDATA[longitudinal cancer study]]></category>
		<category><![CDATA[longitudinal monitoring]]></category>
		<category><![CDATA[melanoma treatment response markers]]></category>
		<category><![CDATA[metastasis]]></category>
		<category><![CDATA[next-generation sequencing]]></category>
		<category><![CDATA[radiologic assessment versus liquid biopsy]]></category>
		<category><![CDATA[radiologic response]]></category>
		<category><![CDATA[RECIST]]></category>
		<category><![CDATA[tumor heterogeneity]]></category>
		<category><![CDATA[tumor heterogeneity and patchiness]]></category>
		<category><![CDATA[tumor response monitoring]]></category>
		<category><![CDATA[tumor volume]]></category>
		<category><![CDATA[tumor volume assessment]]></category>
		<category><![CDATA[unresectable stage III and IV melanoma]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=227599</guid>

					<description><![CDATA[A longitudinal study of advanced melanoma patients shows that circulating tumor DNA tracks tumor burden and radiologic response, but its reliability varies sharply with metastatic site and timing.]]></description>
										<content:encoded><![CDATA[<p>For patients with advanced melanoma, tracking how a tumor responds to treatment has long depended on two imperfect tools: periodic imaging scans and, more recently, blood tests that detect fragments of DNA shed by cancer cells. A new study from researchers at the University Medical Center Hamburg-Eppendorf, published in the Journal of Translational Medicine, has now put both approaches under the microscope at unprecedented resolution, and the results reveal a picture far more complicated than either method alone can capture. By following 42 patients with unresectable stage III or IV melanoma who were treated with immune checkpoint inhibitors, the team assembled one of the most detailed longitudinal datasets to date, pairing 241 circulating tumor DNA measurements with radiologic assessments and quantitative measurements of tumor volume.</p>
<p>The central question was deceptively simple: does the amount of tumor DNA floating in a patient&#8217;s plasma actually mirror what radiologists see on a scan? The answer, according to the analysis led by Isabel Heidrich, with Klaus Pantel and Christoffer Gebhardt as senior authors, is a qualified yes. Circulating tumor DNA levels rose and fell in broad agreement with disease status, increasing significantly as radiologic response worsened across the standard RECIST 1.1 categories, from complete remission through partial remission and stable disease to progression. The statistical association was modest but real, with a Spearman correlation coefficient of 0.31 and a p-value of 0.002 across 99 paired time points.</p>
<p>Yet the study&#8217;s most valuable contribution may be its honest accounting of where that agreement breaks down. When the researchers tested how well a single ctDNA measurement could identify progressive disease, the discriminative performance was only moderate, yielding an area under the receiver operating characteristic curve of 0.69. Threshold analyses exposed a fundamental trade-off that clinicians will recognize immediately. Setting the bar high, at 25 or more mutant molecules per milliliter of plasma, produced strong specificity of at least 83 percent but sensitivity of no more than 30 percent, meaning the test rarely cried wolf but also missed most progressing patients. Lower thresholds of one to two mutant molecules per milliliter hovered around 56 percent for both sensitivity and specificity, a level of accuracy that cannot stand alone.</p>
<p>To move beyond categorical imaging readouts, the team also compared ctDNA concentrations directly with total metastatic tumor volume, calculated quantitatively rather than judged by eye. Here the correlation was stronger: ctDNA levels tracked tumor volume with a Spearman coefficient of 0.46, highly significant at p less than 0.0001 across 73 paired time points. Crucially, timing mattered. When blood draws and imaging occurred within 30 days of each other, the correlation tightened to 0.56, while measurements separated by longer intervals showed weaker agreement. This temporal effect carries a practical lesson for clinical trials and routine care alike: a ctDNA result is most informative about tumor burden when it is anchored closely in time to an imaging reference point.</p>
<p>Perhaps the most striking finding, however, concerned change itself. If ctDNA is a faithful liquid biopsy of tumor dynamics, then a rise or fall in plasma DNA should parallel a corresponding change in tumor volume. It did not. Dynamic changes in ctDNA were not significantly correlated with changes in tumor volume, with a correlation coefficient of just 0.20 and a p-value of 0.25. In other words, a patient whose ctDNA dropped sharply was not reliably the patient whose tumors shrank the most. This decoupling of trajectories suggests that ctDNA shedding is governed by biology that a ruler on a scan cannot see, including cell death rates, vascularization, and the metabolic state of individual metastases.</p>
<p>That spatial dimension emerged forcefully from the organ-specific analyses. The strength of the association between ctDNA and tumor burden varied dramatically depending on where the metastases were located. Lymph node and peritoneal metastases showed comparatively strong relationships between ctDNA levels and disease status, while lung, liver, and brain metastases contributed far less detectable DNA to the bloodstream. This pattern of differential shedding has direct clinical implications: a patient whose disease is confined to visceral sites may have undetectable ctDNA despite substantial tumor burden, while another with bulky nodal disease may show abundant plasma DNA. A negative blood test, the study suggests, cannot be interpreted without knowing the anatomy of the disease it is meant to represent.</p>
<p>The researchers also quantified how often ctDNA dynamics and radiologic assessments actually agreed. Concordance was high among patients whose disease was clearly responding, reaching 85 percent in those with complete or partial remission. In stable or progressive disease, agreement fell to 72.9 percent. The discordant cases, rather than being dismissed as noise, were examined descriptively and linked to three plausible culprits: tumor heterogeneity within and across metastatic sites, differences in the timing between blood draws and scans, and treatment-related factors that may alter shedding independently of tumor cell numbers. Immune checkpoint inhibitors, which unleash immune cells to attack tumors, may cause inflammatory swelling or delayed shrinkage that complicates both imaging and biomarker readouts in the early weeks of therapy.</p>
<p>Technically, the study relied on a UMI-based amplicon next-generation sequencing assay capable of detecting mutations in BRAF, EGFR, KRAS, NRAS, and PIK3CA. Unique molecular identifiers allow the sequencing platform to distinguish true mutant fragments from errors introduced during amplification, a critical safeguard when hunting for a handful of mutant molecules in a sea of healthy cell-free DNA. By quantifying ctDNA as mutant molecules per milliliter rather than as a binary positive-or-negative call, the assay enabled the continuous, high-frequency sampling that made the temporal analyses possible. The retrospective design and the modest cohort size of 42 patients mean the findings should be validated prospectively, but the density of sampling, 241 time points, gives the conclusions a robustness that sparse datasets cannot match.</p>
<p>What emerges from the combined analysis is neither a triumph for liquid biopsy nor a rebuttal of it, but a map of its boundaries. ctDNA clearly reflects radiologic disease status and overall tumor burden, and its correlation with volume strengthens when measurements are temporally aligned. At the same time, the moderate discrimination of progression, the weak link between ctDNA dynamics and volume changes, and the pronounced heterogeneity of shedding across metastatic sites all argue against replacing scans with blood tests. Instead, the authors position ctDNA as a complementary biomarker, one that adds a molecular, real-time layer to the anatomical snapshot provided by CT and MRI. For a disease like advanced melanoma, where immunotherapy can produce deep and durable responses in some lesions while others escape, that layered view may be exactly what clinicians need to catch relapse earlier and tailor treatment with greater confidence.</p>
<p><strong>Subject of Research:</strong> Longitudinal ctDNA monitoring and its relationship to radiologic response and tumor volume in advanced melanoma</p>
<p><strong>Article Title:</strong> Integrated longitudinal analysis of ctDNA, radiologic response, and tumor volume reveals spatial and temporal heterogeneity in advanced melanoma</p>
<p><strong>Article References:</strong> Heidrich, I., Streckenbach, A., Rautmann, C., Freiberg, H., Kött, J., Geidel, G., Rünger, A., Zell, T., Roeper, C., Hansen-Abeck, I., Abeck, F., Schneider, S. W., Smit, D. J., Pantel, K., &amp; Gebhardt, C. (2026). Integrated longitudinal analysis of ctDNA, radiologic response, and tumor volume reveals spatial and temporal heterogeneity in advanced melanoma. <em>Journal of Translational Medicine, 24</em>(1), Article 1199. <a href="https://doi.org/10.1186/s12967-026-08899-0" rel="noopener noreferrer">https://doi.org/10.1186/s12967-026-08899-0</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1186/s12967-026-08899-0" rel="noopener noreferrer">10.1186/s12967-026-08899-0</a></p>
<p><strong>Keywords:</strong> ctDNA, liquid biopsy, advanced melanoma, immune checkpoint inhibitors, tumor volume, RECIST, tumor heterogeneity, next-generation sequencing, radiologic response, longitudinal monitoring, metastasis, biomarker</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">227599</post-id>	</item>
		<item>
		<title>Wearable Sensors Track Sleep and Movement Across Pregnancy, Study Finds</title>
		<link>https://scienmag.com/wearable-sensors-track-sleep-and-movement-across-pregnancy-study-finds/</link>
		
		<dc:creator><![CDATA[Harold Sullivan]]></dc:creator>
		<pubDate>Tue, 22 Sep 2026 17:37:29 +0000</pubDate>
				<category><![CDATA[Psychology & Psychiatry]]></category>
		<category><![CDATA[24-hour movement behaviors]]></category>
		<category><![CDATA[accelerometer]]></category>
		<category><![CDATA[actigraphy]]></category>
		<category><![CDATA[daily sleep diary methods in pregnancy studies]]></category>
		<category><![CDATA[feasibility of wearable technology in pregnancy]]></category>
		<category><![CDATA[feasibility study]]></category>
		<category><![CDATA[impact of pregnancy on sleep patterns]]></category>
		<category><![CDATA[interventions for improving sleep during pregnancy]]></category>
		<category><![CDATA[longitudinal monitoring]]></category>
		<category><![CDATA[Maternal health]]></category>
		<category><![CDATA[Physical activity]]></category>
		<category><![CDATA[Pregnancy]]></category>
		<category><![CDATA[pregnancy health monitoring technology]]></category>
		<category><![CDATA[pregnancy movement monitoring]]></category>
		<category><![CDATA[research-grade accelerometers for pregnant women]]></category>
		<category><![CDATA[Sedentary behavior]]></category>
		<category><![CDATA[sleep and activity data during pregnancy]]></category>
		<category><![CDATA[sleep diaries]]></category>
		<category><![CDATA[sleep health]]></category>
		<category><![CDATA[tracking sedentary behavior in pregnancy]]></category>
		<category><![CDATA[trimester-specific activity and sleep changes]]></category>
		<category><![CDATA[wearable device challenges in pregnancy research]]></category>
		<category><![CDATA[wearable sensors for pregnancy sleep tracking]]></category>
		<category><![CDATA[wearable technology]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=207279</guid>

					<description><![CDATA[A small feasibility study found that pregnant participants could wear a research-grade accelerometer around the clock and complete text-message sleep diaries for months, achieving strong adherence despite technical issues and third-trimester drop-off.]]></description>
										<content:encoded><![CDATA[<p>Pregnancy transforms nearly every aspect of a person&#8217;s daily life, and one of the most profound shifts happens in the quiet rhythm of movement and rest. As the weeks pass, moderate-to-vigorous exercise tends to decline, sedentary time often creeps upward, and sleep becomes shorter, more fragmented, and less satisfying. Researchers have long wanted to capture these changes in fine detail, week by week, to pinpoint the exact moments when behavior shifts and to design interventions that arrive at the right time. Now, a new feasibility study suggests that research-grade wearable technology, paired with simple text-message sleep diaries, can deliver that detailed picture across most of pregnancy — provided researchers plan carefully for sore wrists, dying batteries, and the fatigue of the third trimester.</p>
<p>The study, conducted by investigators at the Kaiser Permanente Northern California Division of Research together with colleagues at the University of Alabama at Birmingham and Stanford University School of Medicine, set out to answer a deceptively simple question: can pregnant individuals wear a research-quality accelerometer around the clock for months while also completing daily sleep diaries, and will they find the experience tolerable? Published in the Journal of Activity, Sedentary and Sleep Behaviors, the research offers one of the first tests of this combined approach using a fully validated, research-grade device rather than the consumer fitness trackers that have dominated prior longitudinal studies in this population.</p>
<p>The distinction between research-grade and consumer-grade devices is more than academic. Consumer wearables such as Fitbit and Garmin trackers are inexpensive, familiar, and easy to deploy at scale, and several earlier pregnancy studies reported that they could feasibly track 24-hour movement over many months. But their proprietary algorithms process raw sensor data into summary categories such as &#8216;active time&#8217; whose meaning relative to public health guidelines remains unclear. Researchers typically cannot access the underlying raw acceleration signals, which limits their ability to apply standardized processing methods, compare results across studies, or probe nuanced day-to-day and week-to-week patterns. Research-grade accelerometers, by contrast, record raw data at high sampling frequencies, allowing investigators to apply transparent, validated algorithms for classifying sleep, sedentary behavior, and physical activity intensity.</p>
<p>Yet objective device data alone cannot tell the whole story of sleep. Sleep health is a multidimensional construct that includes subjective experiences — how satisfied a person feels with their sleep, how rested they feel during the day, how long it takes them to drift off. To capture those dimensions, the study paired continuous accelerometer wear with the consensus sleep diary, a validated self-report instrument administered by text message one hour after each participant&#8217;s usual wake time for seven consecutive days each month. The diaries asked about bedtime, wake time, sleep latency, the number and duration of nighttime awakenings, naps, and perceived sleep quality and sufficiency, creating a subjective complement to the objective motion record.</p>
<p>Ten pregnant members of the Kaiser Permanente Northern California healthcare system were recruited at 10 weeks&#8217; gestation through email invitations and an eligibility survey administered in REDCap. The criteria excluded those on bed rest or activity restriction and those who regularly wore a wrist activity tracker, since either could confound the measurements. All ten participants were employed full-time, married or living with a partner, and highly educated, with a median age of 33 years; half were experiencing their first pregnancy. Each participant received an ActiGraph CentrePoint Insight Watch, a data hub, and a charger by mail, with instructions to wear the device 24 hours a day on the non-dominant wrist, removing it only to charge. Data uploaded wirelessly once per day to a cloud platform, where the research team could monitor adherence in near real time. Participants received gift cards totaling up to 200 dollars for completing the study and a follow-up interview.</p>
<p>The accelerometer data were processed with impressive technical rigor. Raw signals sampled at 32 hertz were aggregated into 60-second epochs, and the Choi algorithm identified wear versus non-wear time. A day counted as valid only if the participant wore the device for at least 10 waking hours. To separate sleep from waking, the team applied the Tracy bedrest algorithm, which estimates in-bed and out-of-bed times from the movement signal itself. Within waking hours, a validated two-regression algorithm classified each second of acceleration as sedentary or active and predicted energy expenditure in metabolic equivalents, or METs. Minutes were then binned into sedentary behavior at or below 1.5 METs, light-intensity activity between 1.6 and 2.9 METs, and moderate-to-vigorous physical activity at or above 3 METs — the full vocabulary of the 24-hour movement framework.</p>
<p>The adherence results were encouraging, with one instructive exception. Nine of the ten participants provided at least four valid accelerometer days per week for an average of 15 weeks, with individual totals ranging from 10 to 23 weeks. Average daily wear time among those nine was a remarkable 23.7 hours, indicating that most participants genuinely kept the watch on around the clock. Adherence hovered between 60 and 90 percent of participants meeting the weekly threshold from gestational weeks 13 through 26, but declined after week 27, with only 55 percent sustaining valid weeks in the third trimester. One participant contributed no usable accelerometer data at all because of charging problems that could not be resolved during the study. Sleep diary completion, by contrast, was consistently strong: at least 70 percent of participants completed four or more of the seven monthly diaries in every follow-up month, and all ten completed the text-based diaries for an average of five of the six study months.</p>
<p>The acceptability findings revealed what participants actually thought of the experience. All respondents said the setup instructions were easy to understand and follow, and 78 percent found the sleep diaries easy to answer — every participant chose text messaging over email as the delivery method, a preference the authors highlight as a practical lesson for future studies. Seven of the nine respondents found the watch comfortable both day and night, but the dissenting minority offered pointed criticism: the device was too large and bulky, and the watch band was uncomfortable and not durable. One-third of participants experienced technical problems, most commonly involving device connectivity or charging, though most were resolved through troubleshooting or equipment replacement. When asked why they joined, a majority cited the desire to contribute to research, followed by the incentive and curiosity about their own accelerometer data — a motivational profile the authors suggest could be leveraged through reminder messages emphasizing the value of each participant&#8217;s data.</p>
<p>Placed against earlier work, the wear-time results sit intriguingly between the consumer-device literature. Prior pregnancy studies using the Garmin Vivosmart HR reported adherence on 75 to 87 percent of calendar days, while studies using the Fitbit Flex reported 22 to 53 percent. This study recorded wear on roughly 61 percent of calendar study days, suggesting that research-grade and consumer-grade devices may produce comparable wear profiles during pregnancy — meaning the choice between them can be driven by data quality needs rather than adherence fears alone. The authors are careful to note that the small feasibility sample, enrolled late in the first trimester, was highly educated and fully employed, so adherence might differ in more socioeconomically diverse populations or among night-shift workers. The weekly and trimester movement and sleep patterns they present are demonstrations of the processing pipeline, not generalizable findings about pregnancy itself.</p>
<p>The study&#8217;s practical recommendations read like a field manual for anyone planning long-term wearable research in pregnancy. Match watch and band size to wrist size to protect both comfort and data quality. Stock spare equipment, train staff in basic troubleshooting, and prepare participants to recognize and report device problems. Send reminders during mid-to-late pregnancy, when wear declines as physical discomfort rises. And administer sleep diaries by text message in the morning, the format participants embraced most readily. With those adjustments, the authors conclude, comprehensive longitudinal measurement of the 24-hour movement profile — sleep, sedentary time, light activity, and vigorous exercise together — is not only possible across pregnancy but acceptable to the people who make it possible: the participants themselves.</p>
<p><strong>Subject of Research:</strong> Longitudinal wearable monitoring of 24-hour movement and sleep across pregnancy using research-grade accelerometers and sleep diaries</p>
<p><strong>Article Title:</strong> Feasibility and acceptability of longitudinal measurement of 24-hour movement profiles across pregnancy using research-grade devices paired with sleep diaries</p>
<p><strong>Article References:</strong> Ryan, E., Asera, A., Pettee Gabriel, K., Manber, R., Quesenberry, C. P., Hallenbeck, B. R., Avalos, L. A., Hedderson, M. M., &amp; Badon, S. E. (2026). Feasibility and acceptability of longitudinal measurement of 24-hour movement profiles across pregnancy using research-grade devices paired with sleep diaries. <em>Journal of Activity, Sedentary and Sleep Behaviors, 5</em>(1), Article 10. <a href="https://doi.org/10.1186/s44167-026-00101-6" rel="noopener noreferrer">https://doi.org/10.1186/s44167-026-00101-6</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1186/s44167-026-00101-6" rel="noopener noreferrer">10.1186/s44167-026-00101-6</a></p>
<p><strong>Keywords:</strong> pregnancy, accelerometer, wearable technology, sleep diaries, physical activity, sedentary behavior, 24-hour movement behaviors, actigraphy, feasibility study, sleep health, longitudinal monitoring, maternal health</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">207279</post-id>	</item>
	</channel>
</rss>
