<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>hollow fiber membrane &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/hollow-fiber-membrane/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Sun, 18 Oct 2026 02:00:22 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>hollow fiber membrane &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>Dopamine-Glued Graphene Oxide Membranes Deliver 99% Pure Hydrogen from Mixed Gases</title>
		<link>https://scienmag.com/dopamine-glued-graphene-oxide-membranes-deliver-99-pure-hydrogen-from-mixed-gases/</link>
		
		<dc:creator><![CDATA[Neil Sanderson]]></dc:creator>
		<pubDate>Sun, 18 Oct 2026 02:00:22 +0000</pubDate>
				<category><![CDATA[Technology and Engineering]]></category>
		<category><![CDATA[advanced materials for hydrogen fuel applications]]></category>
		<category><![CDATA[carbon dioxide capture]]></category>
		<category><![CDATA[carbon dioxide removal from hydrogen production processes]]></category>
		<category><![CDATA[ceramic membrane]]></category>
		<category><![CDATA[ceramic-supported membrane structures for harsh conditions]]></category>
		<category><![CDATA[composite membranes for gas filtration]]></category>
		<category><![CDATA[Decarbonization]]></category>
		<category><![CDATA[doping graphene oxide membranes for hydrogen purification]]></category>
		<category><![CDATA[environmentally friendly hydrogen production methods]]></category>
		<category><![CDATA[gas separation]]></category>
		<category><![CDATA[graphene oxide membrane]]></category>
		<category><![CDATA[graphene oxide membrane design for clean energy]]></category>
		<category><![CDATA[high-purity hydrogen separation from mixed gases]]></category>
		<category><![CDATA[hollow fiber membrane]]></category>
		<category><![CDATA[hydrogen economy]]></category>
		<category><![CDATA[Hydrogen purification]]></category>
		<category><![CDATA[innovative membrane fabrication for hydrogen economy]]></category>
		<category><![CDATA[membrane technology]]></category>
		<category><![CDATA[molecular sieving]]></category>
		<category><![CDATA[mussel-inspired adhesive in membrane technology]]></category>
		<category><![CDATA[polydopamine]]></category>
		<category><![CDATA[pressure swing adsorption alternatives for hydrogen purification]]></category>
		<category><![CDATA[steam methane reforming]]></category>
		<category><![CDATA[ultrathin polydopamine coatings in gas separation]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=303114</guid>

					<description><![CDATA[Brazilian researchers have built a graphene oxide membrane glued to a ceramic hollow fiber with a polydopamine interlayer that delivers 99 percent pure hydrogen from mixed gas feeds, with performance that improves as hydrogen content rises.]]></description>
										<content:encoded><![CDATA[<p>Hydrogen has long been cast as the clean fuel of the future, but the dirty secret of the hydrogen economy is how the gas is actually made and purified. Most of the world&#8217;s hydrogen comes from steam methane reforming, a process that pairs methane with steam at high temperatures and leaves behind carbon dioxide and other contaminants. Separating the hydrogen from that carbon dioxide is currently done with pressure swing adsorption, an energy-hungry and equipment-intensive technology. Now, a team of chemical engineers at the Federal University of Uberlândia in Brazil has reported a membrane that could change the calculus, using an unlikely glue borrowed from mussel biology to build a graphene oxide filter thin enough to let hydrogen race through while holding carbon dioxide back.</p>
<p>The study, published in the Journal of Materials Science, describes a composite membrane built in three layers, each with a distinct job. At the base sits a hollow fiber of alpha-alumina, a hard ceramic chosen for its mechanical strength and tolerance of harsh chemical and thermal conditions. On top of that ceramic skeleton, the researchers deposited an ultrathin film of polydopamine, a synthetic mimic of the adhesive proteins that mussels use to cling to rocks in the surf. Finally, over the polydopamine primer, they laid down a selective layer of graphene oxide nanosheets just 245 nanometers thick, roughly a thousand times thinner than a human hair.</p>
<p>The polydopamine interlayer is the quiet hero of the fabrication strategy. Ceramic supports are porous by design, but their rough, grainy surfaces make it difficult to spread a continuous, defect-free coating of two-dimensional nanosheets. Using atomic force microscopy, the team measured the surface roughness of the pristine alumina fibers at about 120 nanometers. After a 24-hour immersion in a dilute dopamine solution at pH 8.5, a conformal polydopamine film roughly 154 nanometers thick formed on the fiber, smoothing the surface down to about 102 nanometers. The film&#8217;s catechol hydroxyl and amine functional groups then acted as anchoring sites for the graphene oxide, which bonds to the interlayer through hydrogen bonding and, the authors propose, covalent coupling reactions such as Schiff-base and Michael-addition pathways.</p>
<p>The graphene oxide itself was synthesized by a modified Hummers method, the workhorse oxidation route that rips apart graphite crystals and decorates the resulting sheets with oxygen-containing groups. Characterization confirmed the transformation: infrared spectroscopy revealed hydroxyl, epoxy, and carboxylic signatures; Raman spectroscopy showed the disorder ratio jump from 0.150 in pristine graphite to 0.998 in the oxidized product; and X-ray diffraction pinned the interlayer spacing between stacked sheets at 7.86 angstroms, of which about 4.52 angstroms remains as open gallery height after accounting for the electron clouds of the carbon planes themselves. That spacing is the critical dimension. It exceeds the kinetic diameters of both hydrogen, at 2.89 angstroms, and carbon dioxide, at 3.30 angstroms, so neither molecule is strictly excluded by size alone, yet the confined nanochannels still impose a strong transport bias toward the smaller, faster hydrogen.</p>
<p>What sets this study apart from earlier graphene oxide membrane work is not just the membrane but the test protocol. Most reports evaluate separation performance under a single feed composition, typically an equimolar mixture. The Brazilian team instead swept the hydrogen content of their hydrogen-carbon dioxide feed from 25 to 75 mole percent, closer to the variable streams that real industrial reformers and gasifiers actually deliver. The results were strikingly composition-dependent. At the leanest feed, 25 percent hydrogen, the membrane still enriched the permeate to just over 52 percent hydrogen. At an even 50-50 split, the permeate climbed to nearly 93 percent hydrogen with a separation factor of about 11. And at the richest feed of 75 percent hydrogen, the membrane delivered a permeate stream of 99.04 percent hydrogen purity, with a separation factor of 27.44.</p>
<p>The physics behind that trend is a story of competing molecules fighting for the same nanochannels. Carbon dioxide has a quadrupole moment that makes it stick preferentially to the oxygen-containing functional groups lining the graphene oxide galleries. When carbon dioxide is abundant in the feed, it adsorbs inside the channels and travels by an adsorption-assisted mechanism, crowding out hydrogen and degrading selectivity. As the hydrogen fraction rises and the carbon dioxide partial pressure falls, that competitive adsorption weakens, freeing the channels for hydrogen and simultaneously boosting hydrogen permeance and suppressing carbon dioxide leakage. The authors conclude that transport through the membrane is a hybrid of Knudsen diffusion, molecular sieving, and preferential carbon dioxide adsorption, a combination that explains why performance tracks feed composition so closely.</p>
<p>The raw numbers are competitive by any standard. The composite membrane achieved a hydrogen permeance of about 2811 gas permeation units, a measure of flux normalized by pressure and membrane area, alongside that peak separation factor of 27.44. For comparison, a graphene oxide membrane on a zeolitic imidazolate framework support reported by other researchers managed roughly 433 GPU and a separation factor of 14.9 at 250 degrees Celsius, while an externally assembled graphene oxide membrane on alumina reached 876 GPU with a separation factor of 17.2. Even an ethylenediamine-crosslinked variant, which pushed selectivity to about 22.9, paid for it with a permeance drop to around 73 GPU. The Brazilian membrane&#8217;s combination of high flux and respectable selectivity, achieved at room temperature, suggests that the thin, well-adhered selective layer is doing exactly what the polydopamine primer was designed to enable.</p>
<p>Durability matters as much as performance, and here too the results are encouraging. Over 12 hours of continuous pure-gas permeation at a transmembrane pressure of 1 bar, the hydrogen permeance held steady at about 4285 GPU with a net drift of only 0.2 percent between the first and last measurements, while carbon dioxide permeance averaged about 619 GPU with similarly tight variation. The absence of any systematic flux decline over that window indicates that the polydopamine anchor is keeping the graphene oxide layer intact under sustained gas flow, addressing one of the chronic failure modes of nanosheet membranes, which tend to delaminate or reorganize over time.</p>
<p>The broader significance lies in what the composition sweep reveals about how such membranes should be evaluated and deployed. The authors argue that assessing performance across a wide range of feed compositions is essential to represent real-world process conditions, where hydrogen content in reformer off-gas or syngas fluctuates rather than sitting at a convenient laboratory benchmark. Their findings align with established behavior in palladium-silver and ceramic dual-phase membranes, where higher hydrogen partial pressure increases the driving force for permeation. For graphene oxide, the added wrinkle is the adsorption interplay, meaning that process designers cannot simply extrapolate from a single-point measurement.</p>
<p>Challenges remain before dopamine-engineered graphene oxide membranes reach industrial scale. The 12-hour stability test, while reassuring, is short compared with the months of continuous operation a plant would demand, and the tests were run at room temperature rather than at the elevated temperatures where reforming actually occurs. Still, the demonstration that a cheap, bio-inspired polymer primer can turn a rough ceramic fiber into a platform for an ultrathin, high-flux, composition-tolerant hydrogen sieve is a meaningful step. As decarbonization pressures mount across ammonia production, refining, and steelmaking, membranes that can wring high-purity hydrogen from mixed streams without the energy penalty of pressure swing adsorption may prove to be one of the quiet enabling technologies of the energy transition.</p>
<p><strong>Subject of Research:</strong> Graphene oxide composite membranes on polydopamine-modified alumina hollow fibers for hydrogen and carbon dioxide gas separation</p>
<p><strong>Article Title:</strong> High-purity hydrogen for decarbonization via dopamine-engineered α-Al2O3/graphene oxide membranes: the impact of gas mixture feed composition on H2/CO2 separation</p>
<p><strong>Article References:</strong> Ascendino, G. G., Dias, W. A., Reis, M. H. M., &amp; Hori, C. E. (2026). High-purity hydrogen for decarbonization via dopamine-engineered α-Al2O3/graphene oxide membranes: the impact of gas mixture feed composition on H2/CO2 separation. <em>Journal of Materials Science, 61</em>(42), 32709-32726. <a href="https://doi.org/10.1007/s10853-026-13661-4" rel="noopener noreferrer">https://doi.org/10.1007/s10853-026-13661-4</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1007/s10853-026-13661-4" rel="noopener noreferrer">10.1007/s10853-026-13661-4</a></p>
<p><strong>Keywords:</strong> hydrogen purification, graphene oxide membrane, polydopamine, gas separation, carbon dioxide capture, hollow fiber membrane, decarbonization, steam methane reforming, molecular sieving, ceramic membrane, hydrogen economy, membrane technology</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">303114</post-id>	</item>
		<item>
		<title>Oxygen Flows Through Space Membranes Unchanged From Earth to Microgravity</title>
		<link>https://scienmag.com/oxygen-flows-through-space-membranes-unchanged-from-earth-to-microgravity/</link>
		
		<dc:creator><![CDATA[Grant Pearson]]></dc:creator>
		<pubDate>Sat, 12 Sep 2026 11:47:37 +0000</pubDate>
				<category><![CDATA[Space]]></category>
		<category><![CDATA[bioreactor]]></category>
		<category><![CDATA[bioreactors for space food production]]></category>
		<category><![CDATA[engineering challenges in space life support]]></category>
		<category><![CDATA[gas bubble behavior in microgravity]]></category>
		<category><![CDATA[gas dissolution in space liquids]]></category>
		<category><![CDATA[gas-liquid mass transfer]]></category>
		<category><![CDATA[hollow fiber membrane]]></category>
		<category><![CDATA[hollow fiber membrane technology]]></category>
		<category><![CDATA[In-situ resource utilization]]></category>
		<category><![CDATA[Lunar gravity]]></category>
		<category><![CDATA[Martian gravity]]></category>
		<category><![CDATA[membrane contactor]]></category>
		<category><![CDATA[microgravity]]></category>
		<category><![CDATA[microgravity effects on gas transfer]]></category>
		<category><![CDATA[oxygen flow in space missions]]></category>
		<category><![CDATA[oxygen gas exchange in microgravity]]></category>
		<category><![CDATA[oxygen transfer]]></category>
		<category><![CDATA[parabolic flight]]></category>
		<category><![CDATA[PHB biopolymer]]></category>
		<category><![CDATA[space biotechnologies]]></category>
		<category><![CDATA[space life support]]></category>
		<category><![CDATA[space membrane contactors]]></category>
		<category><![CDATA[space membrane gas transfer]]></category>
		<category><![CDATA[space waste recycling and resource management]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=193918</guid>

					<description><![CDATA[Researchers have shown that oxygen transfer through hollow fiber membranes remains statistically unchanged across Earth, Martian, Lunar and microgravity conditions, clearing a key hurdle for space bioreactors.]]></description>
										<content:encoded><![CDATA[<p>Getting gases to dissolve into liquids sounds like one of the least glamorous problems in engineering, yet it sits at the heart of nearly every plan to keep humans alive beyond Earth. Bioreactors that grow food, recycle waste and produce useful polymers on long missions all depend on feeding gases such as oxygen and methane into liquid cultures at a steady, controllable rate. On Earth, engineers usually do this by bubbling gas through a tank, but bubbles behave badly in space: they coalesce, cling to surfaces and refuse to rise, wasting precious feedstock in an environment where every gram matters. A new study published in the journal Space and Planetary Resources offers a strikingly practical answer to a question that has long hovered over space biotechnology: does gravity change how efficiently gases cross a membrane into a liquid? The researchers&#8217; answer, backed by data collected while flying roller-coaster arcs in a modified aircraft, is a resounding no.</p>
<p>The team, drawn from the Colorado School of Mines and the California-based company Mango Materials, tested a hollow fiber membrane contactor, a device in which thousands of thin polypropylene tubes act as selective barriers. Liquid water flows through the inside of the fibers while gas flows around them, and because the hydrophobic membrane repels liquid water but lets gas molecules pass, oxygen can dissolve into the liquid without a single bubble ever forming. Unlike sparging, the interfacial area of such a membrane is fixed and independent of flow rates, and the liquid and gas streams can be tuned independently to thin the boundary layers that limit transfer. The driving force is simply the difference in gas concentration, or partial pressure, between the gas and liquid sides, which is why the researchers suspected gravity should play no role at all. Proving it, however, required taking the apparatus somewhere gravity itself could be switched off.</p>
<p>Their motivation goes beyond fundamental fluid physics. Mango Materials has developed a membrane-aerated bioreactor in which methanotrophic bacteria consume methane and oxygen to build biomass and, when nutrients are withheld, the biopolymer poly-3-hydroxybutyrate, or PHB, a versatile plastic used in additive manufacturing, textiles and even food additives. Methane for such a reactor could be harvested from the Sabatier reaction aboard the International Space Station, where it is currently vented as waste, or pulled directly from the Martian atmosphere. Converting that carbon into PHB would be a textbook example of in-situ resource utilization. But before a membrane-aerated bioreactor can fly, engineers must be sure the gas delivery step itself is indifferent to gravity, so that any gravitational effects seen later in a full bioreactor can be confidently attributed to biology rather than plumbing.</p>
<p>Measuring gas transfer in reduced gravity is brutally constrained by time. During a parabolic flight, the aircraft&#8217;s steep climbs and dives produce stretches of about 15 to 28 seconds of simulated reduced gravity, far too short for commercial methane sensors, whose response times lag well behind the data window. The team therefore focused on oxygen transfer into an abiotic medium of deionized water held at 37 degrees Celsius, the same temperature as the bacterial cultures the system is meant to serve. They selected a compact 3M Liqui-Cel hollow fiber module with fibers 330 micrometers in outer diameter and pores of 0.1 micrometers, chosen for its high flux, small internal volume and transparent shell that allowed visual monitoring for condensation. Fast optical oxygen sensors with a measured response time of just 0.725 seconds, roughly 27 times faster than the oxygenation process itself, made it possible to resolve the transfer dynamics within each brief window of weightlessness.</p>
<p>The apparatus was a marvel of compact engineering, organized into three interlocking subsystems. A pneumatic loop alternated between pure nitrogen, used to strip dissolved oxygen down to about one percent of saturation, and pure oxygen, delivered at one liter per minute through digitally controlled flow controllers with the line held at 20 PSI. A hydraulic loop pumped 560 milliliters of deionized water through the membrane at five liters per minute, past redundant oxygen sensors, pressure gauges and a hydraulic accumulator that compensated for water lost by evaporation through the membrane. A thermal loop of about four liters of water, heated by a Peltier device and coupled through a shell-and-tube heat exchanger, held the test liquid at 37 degrees with an accuracy of plus or minus one degree, using the thermal mass of the larger volume to suppress fluctuations. Flow-activated switches protected the system from freezing or boiling if circulation ever stopped, a safeguard that would prove prescient.</p>
<p>During the flight, two operators pressed identical buttons at the call of each parabola, a redundancy in case nausea compromised one of them, triggering a seven-second pulse of oxygen through the membrane&#8217;s gas side. A triaxial accelerometer mounted near the aircraft&#8217;s center of gravity verified that the simulated environments hit their targets: 0.38 g for Martian gravity, 0.16 g for Lunar gravity and under 0.1 g for microgravity, all within 0.1 g of the intended level during the critical measurement window. The team had planned ten parabolas per gravity level, but a dust containment breach from another experiment ended the flight early, and a more insidious problem emerged during the second set of microgravity parabolas. A bubble that had sat stably in the thermal loop under Martian and Lunar gravity drifted free in weightlessness, lodged in a flow switch and silently shut down the temperature control. The researchers discarded the affected cycles, leaving five valid microgravity measurements, and applied a temperature correction to the remaining data.</p>
<p>When the numbers were crunched, the result was as clean as an experimentalist could hope for. Oxygen mass transfer coefficients averaged between 1.11 and 1.16 times ten to the minus four meters per second across all four gravity conditions, a spread so narrow it borders on statistical indistinguishability. Student&#8217;s T-tests comparing terrestrial, Martian, Lunar and microgravity datasets produced p-values of 0.41, 0.48 and 0.85, all comfortably above the 0.05 threshold, meaning no significant difference could be detected between any pair of gravity levels. The measured coefficients also landed within 25 percent of a theoretical estimate based on the Sherwood relation for hollow fiber modules and matched values reported in earlier terrestrial studies, lending further confidence to the measurements. The slightly larger scatter seen in the reduced-gravity datasets was traced not to gravity itself but to the vibration and acceleration fluctuations inherent in parabolic flight, which accelerometer data and Fourier analysis confirmed were far quieter during the terrestrial baseline.</p>
<p>The implications ripple outward well beyond bioreactors. Because membrane contactors transfer gas in both directions, they can not only deliver feed gases but also strip waste products from a reaction, and by Le Chatelier&#8217;s principle, removing a product can itself accelerate the underlying chemistry. Membrane contactors already maximize biomethane recovery in anaerobic wastewater treatment on Earth, and they are being integrated into electrolyzer electrodes, where gas bubbles that stubbornly cling to surfaces in reduced gravity would otherwise choke off hydrogen and oxygen production. The new result provides a crucial assurance for those designs: if a membrane-enhanced electrolyzer or bioreactor performs differently in space, the credit or blame belongs to the electrochemistry or the microbes, not to the gas delivery hardware. The findings also raise the Technology Readiness Level of membrane gas transfer for space life support, a milestone that agencies weigh heavily when deciding which technologies earn a berth on future missions.</p>
<p>The team is now looking toward the next logical step: a small demonstration membrane-aerated bioreactor designed for long-duration operation aboard the International Space Station, where the biological half of the methane-to-PHB process can finally be tested under sustained weightlessness. In the meantime, the parabolic flight rig itself may prove as valuable as the result it produced. The authors note that the system, capable of completing a full oxygen transfer measurement in under ten seconds through an innovative dual water loop design, could be readily adapted to compare different membrane modules or to measure the transfer rate of any pure gas for which an inline sensor exists, positioning it as a high-throughput characterization tool for next-generation membrane materials. For a field in which every launch opportunity is scarce and every kilogram of hardware is fought over, a technology that works exactly the same on Earth as it does on the Moon, Mars or in the void between them is precisely the kind of boring reliability that space exploration depends on.</p>
<p><strong>Subject of Research:</strong> Membrane gas–liquid oxygen mass transfer under variable gravity conditions during parabolic flights</p>
<p><strong>Article Title:</strong> Experimental system for investigating membrane gas–liquid mass transfer during a parabolic flight</p>
<p><strong>Article References:</strong> Bray, A., Lampe, J., Schwiebert, A. M., Bush, J. A., Jacobs, A., Force, N., Pieja, A., Munakata-Marr, J., &amp; Vanneste, J. (2026). Experimental system for investigating membrane gas–liquid mass transfer during a parabolic flight. <em>Space and Planetary Resources, 2</em>(1), Article 2. <a href="https://doi.org/10.1007/s44461-026-00007-w" rel="noopener noreferrer">https://doi.org/10.1007/s44461-026-00007-w</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1007/s44461-026-00007-w" rel="noopener noreferrer">10.1007/s44461-026-00007-w</a></p>
<p><strong>Keywords:</strong> membrane contactor, hollow fiber membrane, gas-liquid mass transfer, parabolic flight, microgravity, Martian gravity, Lunar gravity, oxygen transfer, bioreactor, in-situ resource utilization, space life support, PHB biopolymer</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">193918</post-id>	</item>
	</channel>
</rss>