<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Ground source heat pumps &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/ground-source-heat-pumps/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Sun, 18 Oct 2026 16:08:19 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>Ground source heat pumps &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>Ground Beats Air in Year-Long Heat Pump Trial, but Refrigerant Choice Decides the Winner</title>
		<link>https://scienmag.com/ground-beats-air-in-year-long-heat-pump-trial-but-refrigerant-choice-decides-the-winner/</link>
		
		<dc:creator><![CDATA[Denise Maddox]]></dc:creator>
		<pubDate>Sun, 18 Oct 2026 16:08:19 +0000</pubDate>
				<category><![CDATA[Technology and Engineering]]></category>
		<category><![CDATA[air source heat pump]]></category>
		<category><![CDATA[air source heat pumps]]></category>
		<category><![CDATA[Amman]]></category>
		<category><![CDATA[coefficient of performance]]></category>
		<category><![CDATA[decarbonizing heating and cooling]]></category>
		<category><![CDATA[energy efficiency]]></category>
		<category><![CDATA[fossil fuel dependence in heating]]></category>
		<category><![CDATA[geothermal energy]]></category>
		<category><![CDATA[ground source heat pump]]></category>
		<category><![CDATA[Ground source heat pumps]]></category>
		<category><![CDATA[ground temperature impact on heat pump performance]]></category>
		<category><![CDATA[ground vs. air source heat pump comparison]]></category>
		<category><![CDATA[heat pumps]]></category>
		<category><![CDATA[heating and cooling]]></category>
		<category><![CDATA[hot and arid climate heat pump efficiency]]></category>
		<category><![CDATA[R134a]]></category>
		<category><![CDATA[R410A]]></category>
		<category><![CDATA[R513A]]></category>
		<category><![CDATA[refrigerant selection in heat pumps]]></category>
		<category><![CDATA[refrigerant types and heat pump efficiency]]></category>
		<category><![CDATA[refrigerants]]></category>
		<category><![CDATA[renewable energy for heating and cooling]]></category>
		<category><![CDATA[thermodynamic modeling of heat pumps]]></category>
		<category><![CDATA[year-long heat pump performance study]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=306699</guid>

					<description><![CDATA[A year-long field study in Amman shows ground source heat pumps consume less electricity annually than air source units, but per unit of heat delivered the air source system with R410A holds a slight efficiency edge.]]></description>
										<content:encoded><![CDATA[<p>Heat pumps have become the centerpiece of the global push to decarbonize heating and cooling, but a new experimental and modeling study from Jordan suggests that the technology&#8217;s real-world performance hinges on two decisions at once: where the heat pump draws its low-grade heat from, and which refrigerant circulates inside its pipes. Researchers at the German Jordanian University and collaborating institutions combined a full year of field-measured ground temperatures in Amman with a detailed thermodynamic model of air source and ground source heat pumps, testing three refrigerants across both architectures. Their findings, published in Results in Engineering, offer one of the most granular head-to-head comparisons yet between the two dominant heat pump designs in a hot, arid climate.</p>
<p>The stakes are considerable. Global energy demand is projected to rise by roughly 48 percent by 2040, and heating and cooling remain stubbornly dependent on fossil fuels. Renewable energy currently supplies only about 23 percent of the heating and cooling sector, a share that lags far behind the rapid gains made in renewable electricity. Heat pumps, which move heat rather than generate it, are widely seen as the most promising bridge technology, but their efficiency depends intimately on the temperature of the reservoir they tap. Air source heat pumps extract thermal energy from ambient air, which is easy to install but fluctuates wildly with the seasons. Ground source systems bury a heat exchanger in the soil, where temperatures remain nearly constant year-round, but they demand drilling, land, and higher upfront capital.</p>
<p>The research team, led by Mustafa Jaradat with Omar Alsotary, Ohoud Aljaloudi, and Madhar Haddad, anchored their analysis in real measurements rather than generic design assumptions. They drilled a ten-meter borehole at the Amman site, lined it with PVC pipe, and lowered a copper-tube heat exchanger into the ground. A UNI-T UT330-USB data logger, rated to ±0.5 °C accuracy and protected against water and dust ingress, recorded ground temperature continuously from December 2021 to December 2022. Over that full annual cycle, the soil temperature at the borehole base stayed within a remarkably narrow band of 21.7 to 22.8 °C, confirming the thermal stability that makes ground source systems attractive in the first place.</p>
<p>To probe how much heat the ground could actually deliver, the team circulated tap water through a two-meter copper coil, manually rolled into a spiral and suspended ten meters below the surface. Water entered the ground loop at roughly 13 to 15 °C and emerged at up to 18.7 °C, a gain of about 3.7 °C that the researchers used in a sensible-heat energy balance to calculate the ground-side heat transfer rate. A short circulation test showed the soil temperature dropping from 22.1 to 21.7 °C as heat was extracted, corresponding to a daily degradation rate of 0.088 °C per day. Crucially, the authors caution that this short-cycle rate describes only the instantaneous response of the coil during active circulation; the full-year record shows the undisturbed ground swings far less than a naive extrapolation would suggest.</p>
<p>On the modeling side, the team built a first-order thermodynamic model of a vapor-compression heat pump cycle, defining four key states: saturated vapor at the compressor inlet, superheated vapor at the compressor outlet, saturated liquid at the condenser outlet, and a saturated mixture after the expansion valve. The model held the indoor setpoint at 24 °C and 38 percent relative humidity, with the compressor outlet fixed at 70 °C and 1866 kPa for the R410A case. A compressor isentropic efficiency of 0.75 was applied uniformly across all three refrigerants to keep the comparison fair. The expansion valve was treated as an isenthalpic throttling device, analyzed through the Joule-Thomson coefficient, which governs how much the refrigerant cools as its pressure drops.</p>
<p>Three refrigerants were put through this framework: R410A, the workhorse of modern residential heat pumps with a global warming potential of 2088; R134A, an older benchmark refrigerant with a GWP of 1430; and R513A, a lower-GWP blend at 631 that is positioned as a near-drop-in alternative to R410A. The inclusion of R513A is what gives the study its contemporary edge, because international agreements such as the Kigali Amendment to the Montreal Protocol and the EU F-Gas Regulation are phasing down high-GWP hydrofluorocarbons. The question is whether a greener refrigerant can match the thermodynamic performance of the incumbent, or whether efficiency and climate impact remain locked in a trade-off.</p>
<p>The answer, at least for the air source configuration, is that R410A still wins on raw efficiency. Modeled against the full October-to-March weather record for Amman, the R410A air source heat pump achieved an average coefficient of performance of 4.97, with hourly values ranging from 4.22 to 6.20. R513A came in at an average COP of 3.49, ranging from 2.97 to 4.50, while R134A trailed at 3.13 on average. Hourly compressor power told the same story: R410A consumed the least, between 0.79 and 1.05 kWh, R513A sat in the middle at 0.82 to 1.27 kWh, and R134A demanded the most at 0.91 to 1.44 kWh. R410A also absorbed the most heat at the evaporator, peaking at 4.14 kWh, compared with 2.86 kWh for R513A and 2.79 kWh for R134A.</p>
<p>The ground source system, by contrast, drew its evaporator heat from a buffer tank of water held at a steady 18 °C, fed by the buried heat exchanger. The model assumed the refrigerant left the evaporator as saturated vapor at 15 °C and 1250.8 kPa, conditions tied directly to the measured buffer-tank temperature rather than an assumed design margin. Scaled so that its delivered heating capacity met the same one-ton target used to size the air source unit, the ground source heat pump achieved a COP of 4.79, delivering 3.51 kW of heat with a compressor power of 0.73 kW and an evaporator load of 2.78 kW. Its annual electricity consumption came to approximately 3203 kWh, lower than any of the three air source configurations, which ranged from 4095 kWh for R410A to 5283 kWh for R134A.</p>
<p>But the authors are careful not to declare an unconditional winner. The ground source system&#8217;s lower absolute consumption partly reflects its smaller delivered capacity, 3.51 kW versus roughly 4.65 kW for the air source unit, rather than efficiency alone. Per unit of heat actually delivered, the air source heat pump running R410A retains a marginally higher COP of 4.97 compared with the ground source system&#8217;s 4.79. The ground source advantage lies elsewhere: its hour-to-hour energy consumption is remarkably steady because the underground temperature barely moves, whereas the air source system&#8217;s output fluctuates with every cold snap. The researchers also quantified their measurement uncertainty, noting that the ±0.5 °C sensor accuracy propagates to roughly ±19 percent on the 3.7 °C temperature difference used in the ground-side heat calculation, a band too narrow to explain the 28 percent gap in annual electricity between the two systems.</p>
<p>The study&#8217;s broader message is that refrigerant selection and heat source selection are not independent choices. R410A delivers the strongest thermodynamic performance in both architectures but carries the heaviest climate burden, while R513A offers a meaningful reduction in global warming potential at a measurable cost in efficiency. R134A, the legacy option, performs worst on both counts in this comparison. For homeowners and policymakers, the practical takeaway is that the optimal configuration depends on priorities: if minimizing electricity per unit of heat is the goal, the air source heat pump with R410A leads among the modeled options; if steady output and lower absolute consumption at a smaller capacity are preferred, and if drilling costs and land availability permit, the ground source system with R410A remains a defensible choice. As heat pump adoption accelerates worldwide, studies like this one, grounded in a full year of site-specific measurements rather than generic assumptions, will be essential for guiding that transition in the climates where it matters most.</p>
<p><strong>Subject of Research:</strong> Comparative experimental and modeling analysis of air source and ground source heat pumps using R410A, R134A, and R513A refrigerants</p>
<p><strong>Article Title:</strong> Experimental and comparative analysis of air source and ground source heat pumps: refrigerant performance and energy efficiency</p>
<p><strong>Article References:</strong> Jaradat, M., Alsotary, O., Aljaloudi, O., &amp; Haddad, M. (2026). Experimental and comparative analysis of air source and ground source heat pumps: refrigerant performance and energy efficiency. <em>Results in Engineering, 32</em>, Article 113582. <a href="https://doi.org/10.1016/j.rineng.2026.113582" rel="noopener noreferrer">https://doi.org/10.1016/j.rineng.2026.113582</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1016/j.rineng.2026.113582" rel="noopener noreferrer">10.1016/j.rineng.2026.113582</a></p>
<p><strong>Keywords:</strong> heat pumps, ground source heat pump, air source heat pump, R410A, R513A, R134A, coefficient of performance, refrigerants, geothermal energy, energy efficiency, Amman, heating and cooling</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">306699</post-id>	</item>
	</channel>
</rss>
