<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>gold electrode &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/gold-electrode/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Sun, 04 Oct 2026 07:14:12 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>gold electrode &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>Bare Gold Electrode Detects Trace Mercury in Water Without Nanocoatings</title>
		<link>https://scienmag.com/bare-gold-electrode-detects-trace-mercury-in-water-without-nanocoatings/</link>
		
		<dc:creator><![CDATA[Denise Maddox]]></dc:creator>
		<pubDate>Sun, 04 Oct 2026 07:14:12 +0000</pubDate>
				<category><![CDATA[Technology and Engineering]]></category>
		<category><![CDATA[advancements in electrochemical water quality testing]]></category>
		<category><![CDATA[challenges in detecting trace heavy metals in water]]></category>
		<category><![CDATA[chemometric validation in environmental analysis]]></category>
		<category><![CDATA[chemometrics]]></category>
		<category><![CDATA[cost-effective sensors]]></category>
		<category><![CDATA[detection limit]]></category>
		<category><![CDATA[electroanalytical chemistry]]></category>
		<category><![CDATA[electrochemical sensing of mercury ions]]></category>
		<category><![CDATA[environmental impact of inorganic mercury and methylmercur]]></category>
		<category><![CDATA[Environmental Monitoring]]></category>
		<category><![CDATA[gold electrode]]></category>
		<category><![CDATA[heavy metal sensing]]></category>
		<category><![CDATA[innovative approaches to environmental monitoring]]></category>
		<category><![CDATA[mercury bioaccumulation in aquatic food chains]]></category>
		<category><![CDATA[mercury detection]]></category>
		<category><![CDATA[mercury ion measurement techniques]]></category>
		<category><![CDATA[mercury pollution from industrial discharge and coal emissions]]></category>
		<category><![CDATA[nanocoatings vs. unmodified electrodes for contaminant detection]]></category>
		<category><![CDATA[selectivity]]></category>
		<category><![CDATA[simple and cost-effective mercury sensors]]></category>
		<category><![CDATA[square-wave voltammetry]]></category>
		<category><![CDATA[trace analysis]]></category>
		<category><![CDATA[Trace mercury detection in water using bare gold electrodes]]></category>
		<category><![CDATA[water contamination]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=234066</guid>

					<description><![CDATA[Researchers in India have shown that a bare, unmodified gold electrode combined with square-wave voltammetry and chemometric validation can detect trace mercury ions in water as reliably as nanomaterial-based sensors.]]></description>
										<content:encoded><![CDATA[<p>Mercury is one of the most notorious poisons in the global water supply, and detecting it quickly, cheaply and reliably has long been a challenge for environmental chemists. A new study published in the journal Ionics by Monika Antil and Babankumar S. Bansod of CSIR-Central Scientific Instruments Organisation in Chandigarh, India, reports a strikingly simple answer: instead of coating an electrode with engineered nanomaterials, the researchers stripped the sensing platform down to a bare, unmodified gold electrode and used statistical chemometric validation to prove that it can measure mercury ions at trace levels in real water. The work, published on 17 September 2026, challenges a dominant trend in electrochemical sensing, where laboratories compete to decorate electrode surfaces with ever more exotic nanostructures in pursuit of lower detection limits.</p>
<p>The target of the study is the mercuric ion, Hg²⁺, which the authors describe as one of the top toxic water contaminants. Mercury enters rivers, lakes and groundwater through industrial discharge, mining activity and the atmospheric deposition of emissions from coal combustion. Once in aquatic ecosystems, inorganic mercury can be converted by microorganisms into methylmercury, an organic form that bioaccumulates efficiently in fish and shellfish and works its way up the food chain into human diets. The health consequences of chronic exposure are severe: mercury is a potent neurotoxin that damages the central nervous system, kidneys and developing foetuses, which is why regulatory agencies worldwide impose strict limits on mercury concentrations in drinking water and food. Sensitive and selective detection at trace levels is therefore not an academic luxury but a public health necessity.</p>
<p>Electrochemical methods, particularly stripping voltammetry, have become powerful alternatives to laboratory-bound instrumental techniques such as atomic absorption spectrometry and inductively coupled plasma mass spectrometry. In a typical stripping experiment, mercury ions in solution are first preconcentrated onto the working electrode by applying a suitable potential, which reduces the ions and deposits elemental mercury on the surface. The deposited mercury is then stripped back into solution by scanning the potential, and the resulting current peak is proportional to the amount of mercury originally present. This preconcentration step is what gives stripping voltammetry its extraordinary sensitivity, allowing detection at parts-per-billion concentrations with relatively inexpensive portable instrumentation. Gold has always been a favourite electrode material for mercury sensing because mercury forms a spontaneous amalgam with gold, giving the technique a built-in chemical selectivity that few other metal-sensing systems enjoy.</p>
<p>Yet most reported mercury sensors do not simply use gold as it comes. Over the past two decades, the literature has filled with electrodes modified with gold nanoparticles, gold nanospikes, selenium-doped graphite, cobalt hydroxide nanosheets, porous biochar composites with cuprous oxide, MXene nanoribbons, bismuth films and a parade of organic films containing amino or aminophosphonate groups. The rationale is understandable: nanostructuring increases the effective surface area and can boost sensitivity. But the new study argues that this surface complexity comes at a cost. Modified surfaces can be irreproducible from batch to batch, can degrade over time, can introduce their own background signals, and can paradoxically compromise selectivity and signal stability. Every additional layer is also an additional fabrication step, an additional cost and an additional source of variability between sensors.</p>
<p>Antil and Bansod therefore explored a strategy of direct detection of Hg²⁺ using square-wave voltammetry on an unmodified gold electrode, eliminating the need for any coating materials or nanostructured materials. Square-wave voltammetry is a pulse technique in which a symmetrical square-wave potential is superimposed on a slowly changing staircase potential. By sampling the current at the end of each forward and reverse pulse and subtracting the two, the technique cancels out much of the capacitive charging current that would otherwise swamp the faradaic signal from the mercury redox reaction. The result is one of the most sensitive pulse voltammetric methods available, well suited to distinguishing small analytical peaks from background. By combining this technique with the intrinsic mercury-gold amalgam chemistry, the researchers bet that a clean, bare gold surface would be selective enough on its own.</p>
<p>The bet paid off. Under optimised experimental parameters, the bare electrode produced a linear response to Hg²⁺ concentrations ranging from 5 to 50 parts per billion, with a sensitivity of 0.66 microamperes per ppb and a correlation coefficient, R², of 0.99 across the calibration range. The limit of detection came out at 0.42 ppb, a figure comfortably below the stringent drinking-water limits set by major regulatory agencies and comparable to many nanomaterial-based sensors reported in the literature. In practical terms, the sensor can quantify mercury at concentrations relevant to environmental compliance without any of the surface engineering that normally accompanies such performance. The simplicity of the platform also means that electrode preparation reduces essentially to cleaning the gold surface, a procedure that can be standardised far more easily than nanoparticle synthesis.</p>
<p>Selectivity is where many mercury sensors stumble, because real environmental waters contain a cocktail of coexisting metal ions such as copper, lead, cadmium and zinc, along with inorganic species that can produce overlapping electrochemical signals. The researchers carried out systematic interference studies and demonstrated excellent selectivity for Hg²⁺ in the presence of these common coexisting ions. The team then took the crucial step of testing the method in real water samples, where matrix effects, dissolved organic matter and unknown contaminants can distort calibration curves. Recovery experiments in these real samples yielded values between 93 and 110 percent, a range that analytical chemists regard as strong evidence that the method is applicable in complex environmental matrices rather than only in carefully prepared laboratory solutions.</p>
<p>Perhaps the most distinctive feature of the study is its use of chemometric validation, a statistical framework borrowed from analytical chemistry in which the performance of a calibration model is rigorously quantified rather than merely asserted. The researchers report a root mean square error of calibration of 1.9 ppb, a correlation coefficient of 0.99, a bias of zero, a calibration slope of 0.985 and an R² of 0.985 for the predictive model. A slope close to unity and a bias of zero indicate that the sensor&#8217;s predictions track the true concentrations without systematic over- or under-estimation, while the low RMSEC quantifies the typical prediction error. This kind of validation is still relatively rare in the electrochemical sensing literature, where many papers report only a single calibration curve, and it gives end users a realistic picture of how the sensor will behave outside idealised conditions. The authors&#8217; earlier work on arsenic sensing with chemometric calibration suggests this is a deliberate methodological philosophy in their laboratory rather than a one-off.</p>
<p>The implications extend beyond mercury. The study offers a template for simplifying electrochemical sensors across the heavy-metal sensing field, where the race toward nanomaterial modification has sometimes outpaced critical evaluation of whether the added complexity is genuinely necessary. A bare, unmodified electrode is cheaper to manufacture, easier to reproduce, more robust during storage and transport, and better suited to disposable or field-deployable formats such as screen-printed electrodes. For routine environmental monitoring programmes, particularly those connected to initiatives like India&#8217;s National Jal Jeevan Mission, which supported this research through the Ministry of Jal Shakti, the difference between a sensor that requires nanomaterial synthesis and one that requires only a polished gold surface could determine whether the technology ever leaves the laboratory. Cost-effective, reproducible sensors are the currency of real-world water quality surveillance.</p>
<p>Challenges remain before such a platform can be deployed at scale. Field instruments must cope with temperature swings, fouling by organic films, and long-term drift, and the study&#8217;s validation, while thorough, was performed under controlled conditions with real water samples brought to the bench. Nevertheless, the message of the work is clear and likely to resonate widely: sometimes the most advanced sensor is the simplest one. By letting the innate amalgam-forming chemistry of gold do the heavy lifting and by backing the claim with rigorous chemometric statistics, Antil and Bansod have shown that trace mercury detection does not need nanoparticles, coatings or exotic materials. As concerns over mercury contamination of water supplies continue to grow worldwide, a sensor that is simple, cheap, selective and statistically validated may prove exactly what environmental monitoring has been waiting for.</p>
<p><strong>Subject of Research:</strong> Electrochemical detection of mercury ions in water using an unmodified gold electrode with chemometric validation</p>
<p><strong>Article Title:</strong> Simplifying mercury sensing using an unmodified gold electrode with chemometric validation</p>
<p><strong>Article References:</strong> Antil, M., &amp; Bansod, B. S. (2026). Simplifying mercury sensing using an unmodified gold electrode with chemometric validation. <em>Ionics</em>. <a href="https://doi.org/10.1007/s11581-026-07512-0" rel="noopener noreferrer">https://doi.org/10.1007/s11581-026-07512-0</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1007/s11581-026-07512-0" rel="noopener noreferrer">10.1007/s11581-026-07512-0</a></p>
<p><strong>Keywords:</strong> mercury detection, gold electrode, square-wave voltammetry, chemometrics, heavy metal sensing, water contamination, electroanalytical chemistry, trace analysis, environmental monitoring, detection limit, selectivity, cost-effective sensors</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">234066</post-id>	</item>
		<item>
		<title>Bioconjugated Gold Sensor Tracks Melatonin Beyond the Brain</title>
		<link>https://scienmag.com/bioconjugated-gold-sensor-tracks-melatonin-beyond-the-brain/</link>
		
		<dc:creator><![CDATA[Cassandra Pierce]]></dc:creator>
		<pubDate>Thu, 10 Sep 2026 21:02:51 +0000</pubDate>
				<category><![CDATA[Chemistry]]></category>
		<category><![CDATA[advanced electrochemical biosensors]]></category>
		<category><![CDATA[Alzheimer's and Parkinson's biomarkers]]></category>
		<category><![CDATA[antioxidant]]></category>
		<category><![CDATA[bioconjugated gold immunosensor]]></category>
		<category><![CDATA[biosensor]]></category>
		<category><![CDATA[circadian rhythm]]></category>
		<category><![CDATA[circadian rhythm regulation]]></category>
		<category><![CDATA[electrochemical impedance spectroscopy]]></category>
		<category><![CDATA[electrochemistry]]></category>
		<category><![CDATA[extrapineal melatonin functions]]></category>
		<category><![CDATA[extrapineal tissue]]></category>
		<category><![CDATA[gold electrode]]></category>
		<category><![CDATA[immunosensor]]></category>
		<category><![CDATA[melatonin]]></category>
		<category><![CDATA[melatonin detection]]></category>
		<category><![CDATA[mitochondrial melatonin production]]></category>
		<category><![CDATA[neurodegenerative disease biomarkers]]></category>
		<category><![CDATA[portable hormone sensing technology]]></category>
		<category><![CDATA[reactive oxygen species scavenging]]></category>
		<category><![CDATA[square-wave voltammetry]]></category>
		<category><![CDATA[tissue homogenate]]></category>
		<category><![CDATA[tissue-based hormone analysis]]></category>
		<category><![CDATA[tissue-specific melatonin measurement]]></category>
		<category><![CDATA[Wistar rats]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=191852</guid>

					<description><![CDATA[Brazilian researchers have built a bioconjugated gold immunosensor that, for the first time, detects melatonin-associated electrochemical responses in rat kidney, liver, and heart tissue.]]></description>
										<content:encoded><![CDATA[<p>Melatonin has long been celebrated as the brain&#8217;s chemical messenger of darkness, the hormone that rises at nightfall and gently steers the body&#8217;s circadian machinery. Yet a growing body of research has revealed that this indolamine, formally known as N-acetyl-5-methoxytryptamine, is far more than a sleep signal. It is produced not only by the pineal gland but also by mitochondria in peripheral cells, and it accumulates in tissues such as the liver, kidney, heart, placenta, and pancreas. It scavenges reactive oxygen species, dampens inflammation, helps regulate blood pressure, and has been implicated in counteracting the beta-amyloid accumulation associated with Alzheimer&#8217;s disease. Reduced endogenous melatonin levels have been linked to neurodegenerative conditions including Alzheimer&#8217;s, Parkinson&#8217;s disease, dementia, and schizophrenia. The trouble, until now, has been that actually measuring melatonin inside these extrapineal tissues has required bulky, expensive laboratory instrumentation and painstaking sample preparation.</p>
<p>A research team led by Marcos Vilas Boas Filho and Valber de Albuquerque Pedrosa at São Paulo State University (UNESP) in Botucatu, Brazil, working with colleagues at the same institution, has now demonstrated a compact alternative: an electrochemical immunosensor built on a bioconjugated gold electrode that can generate melatonin-associated signals directly in homogenized kidney, liver, and heart tissue from laboratory rats. Published in Discover Electrochemistry, the study is billed as the first proof-of-concept demonstration of electrochemical immunosensing for melatonin in extrapineal tissue. Rather than seeking the lowest detection limit in the field, the team set out to show that antibody-based molecular recognition could be married to electrochemical transduction in matrices as chemically hostile as tissue homogenates.</p>
<p>The analytical chemistry underlying conventional melatonin measurement is well established. Techniques such as chemiluminescence, fluorometry, ultraviolet–visible spectrophotometry, gas chromatography–mass spectrometry, and high-performance liquid chromatography all deliver robust performance, but they demand multiple instrumental platforms, labor-intensive preparation, and long analysis times. Melatonin&#8217;s intrinsic photoreactivity compounds the difficulty, requiring manipulation under light-restricted conditions to prevent degradation. Electrochemical biosensors have emerged as attractive alternatives because of their low detection limits, operational simplicity, and rapid response, and recent years have seen nanostructured platforms achieve impressively low limits of detection in serum, urine, food, and pharmaceutical samples. A paper-based graphite electrode, a molecularly imprinted polymer platform, and a sensor incorporating core–shell Cu@Pt nanoparticles have all reported submicromolar detection. But nearly all of these rely on the direct electrochemical oxidation of melatonin, an approach vulnerable to electrode fouling, matrix interference, and overlapping signals from other electroactive compounds—and none had been applied to extrapineal tissue.</p>
<p>The Brazilian team&#8217;s strategy inverts that logic. Instead of oxidizing melatonin directly, they built an indirect sensing architecture in which the hormone is captured by an immobilized antibody, and its presence is read out as a measurable suppression of a redox probe&#8217;s current. The fabrication begins with a gold electrode 1.7 millimeters in diameter, onto which a self-assembled monolayer of 11-mercaptoundecanoic acid is formed by gold–sulfur bonding, exposing terminal carboxyl groups. These groups are then activated with the classic EDC/NHS coupling chemistry, generating reactive NHS-esters that covalently link to free amine groups on a polyclonal anti-melatonin antibody during overnight incubation at 4 degrees Celsius. The result is the Au/SAM-MUA/anti-ME interface: a stable, antibody-decorated surface in which every subsequent molecular event translates into an electrical signature.</p>
<p>Characterization of the assembly followed the standard toolbox of electroanalytical science. Cyclic voltammetry using the ferricyanide/ferrocyanide couple as a redox probe showed a progressive decline in peak current as each layer was added, confirming that the growing protein and organic films were hindering electron transfer as designed. Electrochemical impedance spectroscopy told the same story quantitatively: the charge-transfer resistance of the bare gold electrode stood at just 5 kilo-ohms, rising to 13 kilo-ohms after monolayer formation, 29 kilo-ohms after EDC/NHS activation, 30 kilo-ohms after antibody immobilization, and a marked 40 kilo-ohms once melatonin bound to the antibody layer. That final jump, the team notes, is the analytical heart of the device—each melatonin molecule captured at the surface adds insulating mass, physically blocking diffusion of the redox probe and deepening the measurable signal.</p>
<p>With square-wave voltammetry optimized at a frequency of 100 hertz, a step potential of 5 millivolts, and a pulse amplitude of 20 millivolts, the researchers calibrated the sensor against commercial melatonin standards across a linear range of 20 to 120 micromolar. The calibration curve carried a negative slope of –0.0034, exactly what the suppression mechanism predicts: the blank current of 0.59 microamperes fell to 0.18 microamperes at 120 micromolar melatonin. The derived figures of merit were a limit of detection of approximately 4 micromolar, a limit of quantification of 14 micromolar, and a striking electrochemical sensitivity of 250 microamperes per micromolar per square centimeter—among the highest sensitivities reported for any electrochemical melatonin platform, and the second highest overall. Recovery analysis with spiked samples reached 99.8 percent, and the sensor held 96.3 percent of its signal between consecutive measurement days, retaining functional integrity for up to eight days before the biological layer required re-immobilization.</p>
<p>Selectivity testing against common biological interferents revealed both strengths and honest limits. Serotonin, dopamine, and uric acid each shifted the redox signal by only 0.8 to 4.0 percent, well within acceptable tolerances. But ascorbic acid alone produced a 9.5 percent suppression, and a mixture of all interferents together caused an 11 percent deviation—statistically significant and a reminder that nonspecific matrix effects can creep into any antibody-based measurement in complex fluids. The authors attribute this partly to possible conformational changes in the antibody at certain pH values, which may partially expose the underlying electrode surface to blocking by other molecules. They are careful to frame the sensor&#8217;s selectivity as demonstrable but not yet definitive under all biological conditions.</p>
<p>The biological application was where the platform earned its novelty claim. Thirty male Wistar rats were divided into a treated group receiving intraperitoneal melatonin at 25 milligrams per kilogram three times weekly for four weeks, and a control group receiving saline. Liver, heart, and kidney samples were harvested, homogenized, and spiked with a known melatonin standard before analysis. Across all three tissues, successive additions of homogenate produced the characteristic progressive suppression of the ferri/ferrocyanide anodic current, and tissues from melatonin-treated animals consistently generated stronger current suppression than control samples. Kidney homogenates produced the greatest effect, followed by heart and liver—a pattern the researchers note aligns with known physiology, since the kidney is central to eliminating melatonin metabolites, the liver metabolizes the hormone via cytochrome P450 enzymes, and cardiac tissue harbors extrapineal melatonin and receptors tied to cardiovascular regulation.</p>
<p>The team is appropriately measured about what the tissue data mean. Because the current-response plots in the homogenates lacked sufficient linearity to derive formal detection limits for those matrices, and because no direct comparison with HPLC or LC–MS/MS was performed, the tissue signals are presented strictly as preliminary, qualitative proof-of-concept responses rather than precise quantifications. Still, the implications are considerable. The work establishes, for the first time, that an antibody-functionalized electrochemical interface can register melatonin-associated differences in kidney, liver, and heart tissue—opening a path toward rapid, point-of-care monitoring of hormone distribution in contexts where chromatography is impractical. The researchers say future work will focus on validating the platform against established chromatographic methods and implementing matrix-matched calibration to sharpen quantitative accuracy, potentially extending the technology to studies of circadian biology, neurodegenerative disease research, and antioxidant therapy monitoring where melatonin&#8217;s reach beyond the brain matters most.</p>
<p>The choice of an indirect immunosensing format carries practical implications worth underscoring. Because melatonin itself is not oxidized at the electrode surface, the many electroactive species that populate tissue homogenates—ascorbate, urate, catecholamines—compete far less directly for the analytical signal. The trade-off is kinetic and structural: antibody–antigen binding is slower than a simple electron-transfer event, and the biological recognition layer is inherently fragile, which is why the team found the interface required re-immobilization after roughly eight days of use. Such operational lifetimes are typical of protein-based sensors and represent a genuine engineering constraint for any future field deployment.</p>
<p>The tissue-specific response pattern observed in the rat study also merits interpretation. The strongest suppression in kidney homogenates is consistent with the organ&#8217;s role as the principal route of melatonin metabolite excretion, while the hepatic signal reflects cytochrome P450-mediated metabolism, the dominant catabolic pathway for the hormone in mammals. Cardiac tissue, meanwhile, is of particular interest because melatonin receptors expressed in myocardium have been linked to blood pressure regulation and cardioprotection, making a rapid tissue-level assay potentially valuable in cardiovascular research.</p>
<p>Methodologically, the spiking approach used in the proof-of-concept experiments deserves note. By adding a known commercial melatonin standard to each homogenate, the researchers could verify that the antibody layer remained functional even amid the proteins, lipids, and salts of a crude tissue matrix. The absence of a chromatographic cross-check, however, means the absolute endogenous concentrations in treated versus control animals remain unknown. Establishing that correlation, alongside matrix-matched calibration curves, will be the decisive next step in determining whether this bioconjugated gold interface can evolve from a qualitative indicator of melatonin-associated tissue responses into a genuinely quantitative analytical instrument for circadian and biomedical research.</p>
<p><strong>Subject of Research:</strong> Development of a bioconjugated gold electrochemical immunosensor for detecting melatonin in extrapineal rat tissues</p>
<p><strong>Article Title:</strong> Electrochemical melatonin detection in extrapineal tissue using a bioconjugated sensor</p>
<p><strong>Article References:</strong> Filho, M. V. B., Agneis, M. L. G., de Souza, M. C., Gavioli, V. D., de Castro, G. R., Seiva, F. R. F., de Almeida Chuffa, L. G., &amp; de Albuquerque Pedrosa, V. (2026). Electrochemical melatonin detection in extrapineal tissue using a bioconjugated sensor. <em>Discover Electrochemistry, 3</em>(1), Article 75. <a href="https://doi.org/10.1007/s44373-026-00162-x" rel="noopener noreferrer">https://doi.org/10.1007/s44373-026-00162-x</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1007/s44373-026-00162-x" rel="noopener noreferrer">10.1007/s44373-026-00162-x</a></p>
<p><strong>Keywords:</strong> melatonin, immunosensor, electrochemistry, biosensor, gold electrode, extrapineal tissue, square-wave voltammetry, electrochemical impedance spectroscopy, Wistar rats, circadian rhythm, antioxidant, tissue homogenate</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">191852</post-id>	</item>
	</channel>
</rss>
