<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>friction damper &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/friction-damper/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Sat, 03 Oct 2026 19:19:05 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.2</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>friction damper &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>Semi-Active Damper With Negative Stiffness Tames Earthquake Shaking Without Adding Peak Forces</title>
		<link>https://scienmag.com/semi-active-damper-with-negative-stiffness-tames-earthquake-shaking-without-adding-peak-forces/</link>
		
		<dc:creator><![CDATA[Violet Maxwell]]></dc:creator>
		<pubDate>Sat, 03 Oct 2026 19:19:05 +0000</pubDate>
				<category><![CDATA[Earth Science]]></category>
		<category><![CDATA[advanced seismic mitigation technologies]]></category>
		<category><![CDATA[base isolation]]></category>
		<category><![CDATA[base-isolated building protection]]></category>
		<category><![CDATA[bidirectional damping effects]]></category>
		<category><![CDATA[Earthquake damping systems]]></category>
		<category><![CDATA[Earthquake engineering]]></category>
		<category><![CDATA[energy dissipation]]></category>
		<category><![CDATA[energy dissipation during specific motion cycles]]></category>
		<category><![CDATA[equivalent linearization]]></category>
		<category><![CDATA[friction damper]]></category>
		<category><![CDATA[hysteresis]]></category>
		<category><![CDATA[innovative earthquake engineering devices]]></category>
		<category><![CDATA[laboratory testing of seismic dampers]]></category>
		<category><![CDATA[low-cycle loading]]></category>
		<category><![CDATA[microcontroller-based damper control]]></category>
		<category><![CDATA[negative stiffness]]></category>
		<category><![CDATA[negative stiffness dampers]]></category>
		<category><![CDATA[optimizing damping to prevent force amplification]]></category>
		<category><![CDATA[seismic energy dissipation]]></category>
		<category><![CDATA[seismic protection]]></category>
		<category><![CDATA[semi-active control]]></category>
		<category><![CDATA[STM32 microcontroller]]></category>
		<category><![CDATA[structural demand reduction during earthquakes]]></category>
		<category><![CDATA[Structural dynamics]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=231598</guid>

					<description><![CDATA[Researchers in China have built and tested a semi-active friction damper that dissipates seismic energy only during unloading, extending structural period without increasing peak damping forces.]]></description>
										<content:encoded><![CDATA[<p>Earthquake engineers have long faced an uncomfortable trade-off. The most straightforward way to protect a building from violent shaking is to add damping, converting seismic energy into heat before it can accumulate in the structure. Yet conventional dampers, whether viscous, friction-based, or metallic, resist motion in both directions of every cycle, and that bidirectional resistance can raise the peak forces the structure must carry. In base-isolated buildings especially, researchers have documented that excessive supplemental damping can amplify floor accelerations and structural demands rather than reduce them. A team at Beijing University of Technology, working with a colleague at Kunming University of Science and Technology, now reports a device designed to escape this dilemma: an Equivalent Negative Stiffness Friction Damper, or ENSFD, that dissipates energy only during half of each motion cycle. The work, published in the Bulletin of Earthquake Engineering, combines analytical modeling, microcontroller-based control, and laboratory testing into a single experimental validation of the concept.</p>
<p>The central idea is deceptively simple. In a force-displacement plot, one complete cycle of motion traces a loop through four quadrants: two where displacement and force share the same sign, and two where they oppose each other. The ENSFD is engineered to deliver substantial damping force only in the second and fourth quadrants, the unloading phases of the cycle, while remaining nearly passive during loading. Because the device never pushes back hard against the structure as it moves in the direction of the driving force, it does not increase the maximum damping force transmitted to the building. At the same time, the asymmetric resistance mimics the effect of negative stiffness, a property that, in structural dynamics, effectively lengthens the period of a structure and softens its response to ground motion. The result is a damper that reshapes the hysteresis loop rather than simply enlarging it, concentrating energy absorption where it does the most good and least harm.</p>
<p>To make this concept usable in engineering practice, the researchers needed a way to represent the nonlinear, half-cycle behavior of the damper with parameters that standard analysis tools can handle. They built a nonlinear single-degree-of-freedom model of the ENSFD and applied the method of slowly varying parameters, an analytical technique for deriving the steady-state response of systems whose properties change gradually over a cycle of motion. From this treatment they extracted equivalent linearization parameters, essentially a stiffness and a damping coefficient that capture the averaged effect of the device over a full oscillation. These equivalent parameters were then checked against direct time-history analysis, in which the full nonlinear equations are integrated step by step under recorded ground motions. The comparison confirmed that the simplified parameters reproduce the response accurately enough for design-level seismic analysis, giving engineers a practical bridge between an exotic nonlinear device and the linearized calculation methods embedded in building codes.</p>
<p>Turning the mathematics into hardware required a control system capable of recognizing, in real time, which phase of the motion cycle the structure is in. The team designed a semi-active ENSFD built around an STM32 microprocessor, a widely used embedded controller with enough speed and reliability for structural applications. The complete system has three cooperating subsystems: a signal acquisition system that measures the structural response, a control system that processes those signals and decides the operating state, and a variable friction execution system that adjusts the friction force accordingly. The controller must distinguish among loading, unloading, and the transitional moments when the direction of motion reverses, because the damper&#8217;s behavior differs fundamentally in each state. Getting this logic right is the difference between a device that dissipates energy selectively and one that degenerates into an ordinary friction damper.</p>
<p>The experimental program consisted of low-cycle reciprocating tests, the standard laboratory protocol for seismic devices, in which the damper is pushed back and forth through many cycles at controlled displacement amplitudes and frequencies. The measured hysteresis curves matched the theoretical expectations: the device provided substantial damping force during unloading while contributing little resistance during loading, producing the characteristic asymmetric loop that defines equivalent negative stiffness behavior. The three subsystems worked together effectively, with the controller making accurate judgments during loading, unloading, and the transitions between them. This is a notable achievement for a semi-active device, since misclassification of the motion state would corrupt the force profile and undermine the entire design rationale.</p>
<p>Beyond confirming the basic behavior, the tests revealed how the damper&#8217;s energy dissipation capacity depends on its operating conditions and internal parameters. The researchers found that energy dissipation is positively correlated with the loading displacement amplitude, which is intuitive, since larger strokes sweep out larger hysteresis loops, and positively correlated with the spring stiffness of the device&#8217;s internal components. It is negatively correlated with the loading frequency, meaning the damper absorbs somewhat less energy per cycle when driven faster. When the team ranked the influencing factors by their impact, the ordering was clear: loading amplitude mattered most, spring stiffness came second, and loading frequency had the least effect. For designers, this hierarchy is valuable because it indicates that the device&#8217;s performance is governed primarily by the seismic demand itself, with the tunable mechanical properties offering a secondary but meaningful degree of control.</p>
<p>The equivalent negative stiffness damping characteristics of the ENSFD serve two complementary functions. First, by effectively extending the structural period, the device shifts the building&#8217;s response away from the frequency content of the earthquake, reducing the accelerations transmitted into the superstructure. This is the same principle that underlies base isolation, but achieved here through a supplementary damping device rather than by modifying the isolation system itself. Second, the concentrated unloading-phase dissipation controls seismic responses without the penalty of increased maximum damping force that accompanies conventional dampers. The authors report that the equivalent parameters derived from their analytical treatment are suitable for engineering analysis, which means the device can be incorporated into standard response-spectrum and time-history workflows without requiring bespoke nonlinear modeling of every installation.</p>
<p>The study situates itself within a growing body of research on negative stiffness and semi-active seismic protection. Negative stiffness devices, including the well-known device developed by Sarlis, Pasala, Constantinou, Reinhorn, Nagarajaiah, and Taylor, and various quasi-zero-stiffness and magnetic spring concepts, aim to reduce apparent structural stiffness and amplify damping effectiveness. Semi-active resettable devices, explored by Chase, Mulligan, and colleagues and by Bobrow, Jabbari, and Thai, demonstrated that reshaping hysteretic behavior with controllable hardware can outperform passive damping. Earlier work by members of the present team, including half-cycle friction damping devices and double triangular damping devices with equivalent negative stiffness for base-isolated buildings, laid the groundwork for the current ENSFD. The new study advances this lineage by closing the loop: a full analytical model, an equivalent linearization scheme validated by time-history analysis, a working electronic control system, and experimental verification in a single coherent program.</p>
<p>The practical significance of the frequency and amplitude findings deserves emphasis. Real earthquakes are broadband, nonstationary signals, and a damper whose output varies strongly with excitation frequency could behave unpredictably across different ground motions. The ENSFD&#8217;s weakest sensitivity being to frequency suggests a degree of robustness that bodes well for real-world deployment, while the strong dependence on displacement amplitude means the device naturally scales its energy absorption with the severity of the response, dissipating more when the structure moves more and less when the motion is mild. That self-scaling behavior is characteristic of well-behaved seismic protective systems and simplifies the task of designing the device for a target performance objective.</p>
<p>Challenges remain before such devices appear in buildings. The laboratory tests were conducted under controlled low-cycle reciprocating loading rather than full-scale shaking table conditions, and long-term reliability of the variable friction mechanism, along with the durability of the sensing and control electronics during years of dormancy punctuated by rare earthquakes, will need further study. Nevertheless, the demonstration that an STM32-based control system can reliably identify loading states in real time, and that the resulting hysteresis behaves as theory predicts, moves the equivalent negative stiffness friction damper from concept toward practice. For a field searching for ways to add damping without adding force, a device that works only half the cycle, and works best when the shaking is worst, is an idea whose time may have come.</p>
<p><strong>Subject of Research:</strong> Semi-active negative stiffness friction dampers for seismic response control of structures</p>
<p><strong>Article Title:</strong> Experimental study and equivalent parameter analysis of a semi-active negative stiffness friction damper</p>
<p><strong>Article References:</strong> Li, W., Peng, L., &amp; Lai, Z. (2026). Experimental study and equivalent parameter analysis of a semi-active negative stiffness friction damper. <em>Bulletin of Earthquake Engineering</em>. <a href="https://doi.org/10.1007/s10518-026-02647-x" rel="noopener noreferrer">https://doi.org/10.1007/s10518-026-02647-x</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1007/s10518-026-02647-x" rel="noopener noreferrer">10.1007/s10518-026-02647-x</a></p>
<p><strong>Keywords:</strong> negative stiffness, friction damper, semi-active control, seismic protection, equivalent linearization, hysteresis, STM32 microcontroller, energy dissipation, base isolation, earthquake engineering, structural dynamics, low-cycle loading</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">231598</post-id>	</item>
		<item>
		<title>Wooden Panels With Friction Dampers Triple Earthquake Energy Dissipation in Aging Concrete Frames</title>
		<link>https://scienmag.com/wooden-panels-with-friction-dampers-triple-earthquake-energy-dissipation-in-aging-concrete-frames/</link>
		
		<dc:creator><![CDATA[Violet Maxwell]]></dc:creator>
		<pubDate>Fri, 02 Oct 2026 10:05:58 +0000</pubDate>
				<category><![CDATA[Earth Science]]></category>
		<category><![CDATA[architectural preservation in seismic retrofit]]></category>
		<category><![CDATA[building renovation]]></category>
		<category><![CDATA[concrete frame earthquake retrofitting]]></category>
		<category><![CDATA[cross-laminated timber]]></category>
		<category><![CDATA[cross-laminated timber panels for seismic damping]]></category>
		<category><![CDATA[e-SAFE project]]></category>
		<category><![CDATA[earthquake energy dissipation techniques]]></category>
		<category><![CDATA[Earthquake engineering]]></category>
		<category><![CDATA[energy dissipation]]></category>
		<category><![CDATA[energy dissipation in aging concrete buildings]]></category>
		<category><![CDATA[energy efficiency]]></category>
		<category><![CDATA[European earthquake retrofit solutions]]></category>
		<category><![CDATA[European Horizon 2020 e-SAFE project]]></category>
		<category><![CDATA[friction damper]]></category>
		<category><![CDATA[friction dampers for structural safety]]></category>
		<category><![CDATA[Horizon 2020]]></category>
		<category><![CDATA[masonry infill]]></category>
		<category><![CDATA[prefabricated timber construction for seismic resilience]]></category>
		<category><![CDATA[quasi-static cyclic testing]]></category>
		<category><![CDATA[reinforced concrete frames]]></category>
		<category><![CDATA[seismic retrofit]]></category>
		<category><![CDATA[seismic safety improvements for pre-1981 concrete structures]]></category>
		<category><![CDATA[sustainable building reinforcement methods]]></category>
		<category><![CDATA[timber-based seismic retrofit]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=227043</guid>

					<description><![CDATA[Full-scale laboratory tests show that an external retrofit combining cross-laminated timber panels with redesigned friction dampers boosts the strength of vulnerable concrete frames by 67 percent and triples their energy dissipation at near-collapse drift levels.]]></description>
										<content:encoded><![CDATA[<p>Millions of reinforced concrete buildings across Europe were constructed before modern seismic codes existed, and many of them are also energy inefficient, uncomfortable, and architecturally dated. Rebuilding them all is neither realistic nor sustainable, so engineers have long searched for retrofit solutions that address structural safety, thermal performance, and aesthetics at the same time. A new study published in the Bulletin of Earthquake Engineering now delivers some of the strongest experimental evidence yet that a timber-based system can do exactly that. Researchers from the University of Bologna and the University of Catania, working within the European Horizon 2020 e-SAFE project, tested a full-scale retrofit concept called e-CLT, which combines prefabricated cross-laminated timber panels with specially engineered friction dampers bolted onto the façades of vulnerable concrete frames.</p>
<p>The scale of the problem motivating this work is striking. According to the most recent Italian census of residential buildings, more than seventy percent of the country&#8217;s housing stock was built before 1981, when seismic design provisions were absent or only partially enforced, and horizontal earthquake forces were rarely considered in routine design. Concrete buildings erected between the 1960s and the 1990s typically lack the ductility that modern capacity design principles provide, and their unreinforced masonry infill walls interact with the frame in ways that can drastically alter seismic behaviour. The consequences have been visible in the devastating earthquakes that struck Molise in 2003, L&#8217;Aquila in 2009, Emilia in 2012, and Central Italy in 2016. At the same time, the building sector accounts for roughly forty percent of energy consumption and thirty-six percent of greenhouse gas emissions in Europe, making integrated renovation an environmental as well as a life-safety imperative.</p>
<p>Existing retrofit strategies each carry significant drawbacks. External steel exoskeletons allow buildings to remain occupied during construction, but they are expensive to fabricate, demand complex connections to the existing structure, and require free space around the entire perimeter for independent foundations, a luxury rarely available in dense cities. Internal solutions such as added shear walls or steel bracing avoid that problem but consume usable floor area and force occupants to endure invasive interior works. Earlier timber-based proposals have shown promise, since cross-laminated timber is lightweight, insulating, and prefabricated, yet most previous systems required removing existing infill walls or transferring substantial new loads into columns that may themselves be degraded. The e-CLT system was conceived to sidestep these limitations by mounting panels externally and letting friction dampers control how forces flow between the new panels and the old frame.</p>
<p>The operating logic of the system is elegantly two-tiered. Under low to moderate ground shaking, the friction dampers hold the CLT panels rigidly against the concrete frame, increasing the building&#8217;s lateral stiffness and strength, which reduces inter-storey drift and the internal forces that would otherwise damage columns and beams. When a severe earthquake strikes, the dampers activate and begin to slide, converting seismic energy into heat through friction while capping the forces transmitted to the timber. This deliberate cap keeps the CLT panels within their elastic range even under extreme excitation, meaning the panels themselves should survive a major event without replacement. A companion prefabricated envelope, called e-PANEL, wraps the assembly to deliver the thermal upgrade, so a single intervention on the façade addresses both earthquake safety and energy performance.</p>
<p>Getting there required fixing a subtle but critical engineering flaw. An earlier version of the friction damper had been validated under idealised laboratory conditions in which only displacements parallel to the friction plane were applied. In a real two-dimensional frame, however, the rocking of the panel during an earthquake generates parasitic forces perpendicular to the friction plane. Preliminary tests showed these out-of-plane actions severely compromised the damper, destabilising its dissipative behaviour, overloading the screws and preloaded bolts, and concentrating stresses at the edges of the concrete elements. The research team therefore redesigned the device from the ground up, decoupling the connection system along the two directions parallel and perpendicular to the friction plane so that rocking motions could no longer corrupt the friction mechanism.</p>
<p>The improved damper consists of two principal steel components: an anchor profile mechanically fixed to the concrete inter-storey beam, and a free profile screwed to the back of the CLT panel that is free to slide horizontally. Between them sits a stiffened alignment component housed in a box formed by three plates welded to the free profile. Energy dissipation occurs as the alignment component slides against the anchor profile across shim layers lubricated with graphite, all clamped together by three bolts tightened to a torque of 100 newton-metres, corresponding to a preload of roughly 31 kilonewtons. The geometry is carefully proportioned using capacity design principles: the friction force is deliberately kept below the resistance of both the timber and concrete fastening systems so that sliding, rather than brittle connection failure, governs, and all steel components remain elastic under the maximum expected friction force. Installation requires just three straightforward operations and no specialist equipment.</p>
<p>To validate the system under realistic conditions, the team built two identical full-scale, single-storey, single-bay concrete frames replicating 1970s Italian construction practice, complete with the strong-beam-weak-column behaviour and low concrete strength typical of that era. Columns measured 300 by 300 millimetres, beams 300 by 500 millimetres, with a 4-metre span and 3.2-metre storey height. Four cyclic quasi-static tests were performed at the University of Bologna&#8217;s structural laboratory: a bare frame loaded only within its elastic range, a masonry-infilled frame pushed to failure, an identical infilled frame retrofitted with the e-CLT system, and finally the retrofit system itself mounted on a deliberately damaged frame whose columns had their reinforcement cut to create a pendulum-like substructure with almost no lateral resistance. This clever arrangement allowed the dampers to be characterised within the real geometric interaction of panel, damper, and frame, rather than in isolation. A constant vertical force of 250 kilonewtons per column simulated the gravity load of a three-storey residential building.</p>
<p>The results were dramatic. The unstrengthened infilled frame developed an initial stiffness of 47.0 kilonewtons per millimetre and reached a peak base shear of 157 kilonewtons at a drift ratio of three percent, by which point plastic hinges had formed at the column ends and the longitudinal reinforcement had buckled. The retrofitted frame, by contrast, exhibited an initial stiffness of 70.1 kilonewtons per millimetre, a 49 percent increase, and a peak base shear of 263 kilonewtons, a 67 percent gain. The friction dampers activated at a drift ratio of about 0.5 percent and then delivered stable, repeatable hysteretic loops of the nearly rectangular shape characteristic of friction devices. Crucially, the CLT panel stayed elastic throughout, with maximum reversible diagonal elongation of only 0.6 millimetres, roughly 200 microstrain, confirming that it behaved as a rigid diaphragm protected by the capped damper forces.</p>
<p>The energy numbers are perhaps the most compelling headline figure. Up to 0.5 percent drift, dissipation was minimal because the dampers had not yet engaged. Beyond that threshold, the retrofitted system&#8217;s cumulative dissipated energy climbed steeply while the unstrengthened specimen&#8217;s performance deteriorated with progressive infill and column damage. At a drift level of three percent, close to the collapse-prevention limits defined in FEMA and Eurocode 8 documents, the strengthened frame dissipated approximately three times as much energy as its unstrengthened counterpart. The equivalent viscous damping ratio of the retrofitted system rose to about 58 percent at three percent drift, compared with a range of roughly 16 to 28 percent for the unstrengthened frame, and showed negligible degradation across repeated cycles. Damage to the concrete members themselves was markedly reduced: cracking remained limited to transverse cracks at column ends, with no bar buckling or concrete cover spalling, in stark contrast to the extensive degradation observed in the control specimen.</p>
<p>The authors conclude that e-CLT is a robust, sustainable route to upgrading seismically vulnerable concrete buildings, one whose stiffness and strength gains can be tailored by adjusting the number and size of dampers and panels, and whose prefabricated, external, lightweight installation minimises disruption to occupants. They also note honest limitations: façades with large openings may not accommodate the panels, brittle failure modes may require supplementary local interventions, and long-term effects such as bolt preload relaxation and temperature fluctuations on the friction interfaces still warrant study. Future work will include shaking-table tests on large-scale three-dimensional specimens and comprehensive cost-benefit analyses. For now, the message is clear: a renewable material, a cleverly decoupled steel damper, and a full-scale laboratory frame have together shown that Europe&#8217;s ageing concrete stock can be made dramatically safer without demolishing a single wall.</p>
<p><strong>Subject of Research:</strong> Seismic retrofit of pre-code reinforced concrete frames using cross-laminated timber panels with friction dampers</p>
<p><strong>Article Title:</strong> Structural performance of RC frames retrofitted with CLT panels: experimental evidence from the e-CLT system</p>
<p><strong>Article References:</strong> Pozza, L., Barbagallo, F., Morganti, A., Licciardello, E., Marino, E. M., &amp; Mazzotti, C. (2026). Structural performance of RC frames retrofitted with CLT panels: experimental evidence from the e-CLT system. <em>Bulletin of Earthquake Engineering</em>. <a href="https://doi.org/10.1007/s10518-026-02690-8" rel="noopener noreferrer">https://doi.org/10.1007/s10518-026-02690-8</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1007/s10518-026-02690-8" rel="noopener noreferrer">10.1007/s10518-026-02690-8</a></p>
<p><strong>Keywords:</strong> cross-laminated timber, seismic retrofit, friction damper, reinforced concrete frames, energy dissipation, quasi-static cyclic testing, e-SAFE project, masonry infill, building renovation, earthquake engineering, energy efficiency, Horizon 2020</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">227043</post-id>	</item>
	</channel>
</rss>
