<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>frequency-selective surface &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/frequency-selective-surface/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Mon, 12 Oct 2026 15:40:36 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>frequency-selective surface &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>Flexible Denim Antenna Array Hears Fluid Build-Up Inside the Knee</title>
		<link>https://scienmag.com/flexible-denim-antenna-array-hears-fluid-build-up-inside-the-knee/</link>
		
		<dc:creator><![CDATA[Denise Maddox]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 15:40:36 +0000</pubDate>
				<category><![CDATA[Technology and Engineering]]></category>
		<category><![CDATA[axial ratio bandwidth]]></category>
		<category><![CDATA[biomedical sensing]]></category>
		<category><![CDATA[biomedical wearable technology]]></category>
		<category><![CDATA[body-centric communication]]></category>
		<category><![CDATA[challenges in compact antenna design for wearables]]></category>
		<category><![CDATA[circular polarisation]]></category>
		<category><![CDATA[flexible textile antennas for biomedical sensing]]></category>
		<category><![CDATA[fluid accumulation sensors integrated into clothing]]></category>
		<category><![CDATA[fluid build-up detection in knees]]></category>
		<category><![CDATA[frequency-selective surface]]></category>
		<category><![CDATA[high-performance MIMO antennas in apparel]]></category>
		<category><![CDATA[jeans substrate]]></category>
		<category><![CDATA[knee phantom]]></category>
		<category><![CDATA[microwave imaging]]></category>
		<category><![CDATA[MIMO]]></category>
		<category><![CDATA[MIMO communication platform on clothing]]></category>
		<category><![CDATA[multi-functional textile antennas]]></category>
		<category><![CDATA[non-invasive edema monitoring]]></category>
		<category><![CDATA[oedema detection]]></category>
		<category><![CDATA[printed antennas on fabric]]></category>
		<category><![CDATA[SAR]]></category>
		<category><![CDATA[wearable antenna]]></category>
		<category><![CDATA[wearable antenna array]]></category>
		<category><![CDATA[wideband circularly polarized antennas]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=265139</guid>

					<description><![CDATA[Researchers have developed a flexible, jeans-fabric four-element circularly polarised MIMO antenna that both communicates wirelessly and detects fluid accumulation in a simulated human knee with a sensitivity of one megahertz per millilitre.]]></description>
										<content:encoded><![CDATA[<p>Engineers have long dreamed of a bandage-like device that could quietly monitor what is happening beneath the skin, and a new study has moved that vision a step closer to reality. Researchers report in Results in Engineering the design, fabrication, and testing of a four-element wearable antenna array, printed on ordinary jeans fabric, that does two jobs at once: it acts as a high-performance multiple-input multiple-output (MIMO) communication platform, and it doubles as a near-field sensor capable of detecting oedema, the accumulation of fluid in and around the human knee. The work, led by J G Sabarish and Priyanka Das, demonstrates that a single flexible textile antenna can simultaneously deliver wideband circularly polarised communication and meaningful biomedical sensing, a combination rarely achieved in the wearable antenna literature.</p>
<p>The central challenge the team set out to solve is one that has dogged compact MIMO antenna designers for years. Placing several radiating elements close together on a small substrate inevitably causes mutual coupling, where energy intended for one element leaks into its neighbours, degrading isolation, diversity performance, and spectral efficiency. Achieving wide impedance bandwidth and wide axial-ratio bandwidth at the same time, while keeping the elements well isolated, has remained a formidable balancing act. Conventional fixes such as frequency-selective surfaces, electromagnetic bandgap structures, and defected ground planes can improve isolation, but they often enlarge the antenna, complicate fabrication, or narrow the very circular-polarisation bandwidth they are meant to protect.</p>
<p>The new design attacks the problem with an unusual combination of geometric tricks. Each of the four antenna elements is built from an asymmetrical ring radiator paired with an anisotropically defected ground structure and a hexagonally slotted circular patch. These features work together to excite pairs of orthogonal modes with equal amplitude and a ninety-degree phase difference, which is the essential recipe for circular polarisation. The result is a remarkably broad 3-dB axial-ratio bandwidth of roughly 47.8 percent, spanning about 5.74 to 9.34 GHz, alongside a 10-dB impedance bandwidth covering 4.62 to 10 GHz. The team verified the underlying physics using characteristic mode analysis, showing that specific orthogonal mode pairs exhibit the required ninety-degree characteristic angle differences at frequencies near 6.13, 7.5, and 9.2 GHz.</p>
<p>Isolation between the four ports is handled by a cleverly engineered frequency-selective surface. The unit cell, a 10 by 10 mm structure on the same 0.8 mm jeans substrate, is deliberately anisotropic so that it responds differently to orthogonally polarised waves. This is the key detail: a generic decoupling structure would suppress the surface waves that cause coupling but could also wreck the circular polarisation. The proposed band-stop cell, evolved through successive stages from a simple square loop into a composite of square loops, triangular loops, and rectangular partitions, blocks transmission below minus 10 dB from 4.5 to 15 GHz while preserving the antenna&#8217;s polarisation purity. Arranged in a cross-shaped layout between adjacent elements, the FSS array pushes inter-element isolation above 25 dB in simulation and above 30 dB in measurement.</p>
<p>The diversity metrics confirm that the array behaves as a proper MIMO system rather than four antennas sharing a board. The envelope correlation coefficient, computed from the scattering parameters, falls below 0.001 across the operating band, indicating that the ports behave nearly independently. Diversity gain exceeds 9.98 dB, the total active reflection coefficient stays below minus 10 dB, the mean effective gains of the ports differ by less than 3 dB, multiplexing efficiency remains above minus 0.1 dB, and channel capacity loss stays under 0.1 bits per second per hertz. Radiation efficiency reaches 98 percent with a peak gain of about 4.5 dBic, and the left-hand circularly polarised waves enjoy cross-polarisation isolation exceeding 22 dB in the broadside direction. Bending tests at radii of 40, 50, 60, and 70 mm confirmed that the flexible substrate tolerates the curvature of a real limb without catastrophic detuning.</p>
<p>The sensing half of the story is where the design becomes genuinely provocative. To model a human knee, the researchers built a cylindrical six-layer phantom replicating skin, fat, muscle, cartilage, bone, and synovial fluid, each layer assigned realistic thickness, density, conductivity, and permittivity. When the antenna rests on the phantom, the fringing near-fields at the patch edges penetrate the tissue stack. Fluid retention raises the effective permittivity of the medium, which capacitively loads the radiating edges, shifts the input impedance, and detunes the resonance. In simulation, the presence of water shifted the resonance from 6.1 GHz, where the reflection coefficient dipped to minus 46.87 dB, to 6.2 GHz with a shallower dip of minus 35.1 dB. The measured sensitivity was one megahertz of frequency shift per millilitre of fluid, with a minimum detectable volume of 20 mL at a depth of 30 mm below the skin layer.</p>
<p>Laboratory validation went beyond simulation. The team prepared a semisolid tissue phantom from agar, water, and corn starch mixtures formulated to mimic the dielectric properties of muscle, fat, skin, and bone, then embedded water-filled polythene packets to represent the oedema condition. The authors are careful to note that this discrete-packet approach models joint effusion, in which fluid accumulates within a confined compartment such as the synovial capsule, rather than diffuse interstitial oedema, and that it provides a controlled, repeatable ground truth for calibration. Measurements were performed in both monostatic configurations, where the same array transmits and receives, and bistatic setups emulating body-to-body wireless networks, with the transmission coefficient falling at roughly 20 dB per decade with distance. Time-domain A-scan analysis further localised the fluid response, with the differential scan highlighting scattering from the fluid layer at approximately 2.4 mm depth in the reflected signal.</p>
<p>Safety, of course, is non-negotiable for any device intended to hug human tissue. Specific absorption rate analysis on the six-layer phantom showed that at 100 mW of input power the 1-gram averaged SAR would reach 4.52 W/kg, exceeding the widely used 1.6 W/kg limit. Because SAR scales linearly with input power, the team calculated a maximum permissible input of 35.4 mW and conducted their compliance analysis at 20 mW with a 5 mm spacing above the skin. Under those conditions the simulated SAR was 0.904 W/kg for 1 gram of tissue and 0.186 W/kg for 10 grams on a normal phantom, dropping to 0.009 and 0.004 W/kg respectively on the hydrated phantom, comfortably within regulatory thresholds.</p>
<p>Compared with prior wearable and circularly polarised MIMO designs, the new antenna stands out on nearly every axis. Its 73.6 percent impedance bandwidth and 47.7 percent axial-ratio bandwidth exceed most reported flexible designs, many of which rely on rigid Rogers substrates unsuitable for conformal wear, suffer from high mutual coupling, or omit SAR analysis entirely. The 98 percent radiation efficiency is the highest among the compared works, and the 10-gram SAR of 0.931 W/kg is lower than several textile competitors. The dual-purpose nature of the design, serving simultaneously as a body-area-network communicator and a microwave fluid sensor, is the novelty the authors emphasise most strongly. If the phantom results translate to clinical settings, a fabric antenna stitched into a knee brace could one day give clinicians a low-cost, radiation-free way to track swelling after injury or surgery, simply by watching a resonance frequency drift.</p>
<p><strong>Subject of Research:</strong> A wearable circularly polarised MIMO antenna on jeans substrate for wireless communication and microwave detection of knee oedema</p>
<p><strong>Article Title:</strong> A wearable circularly polarised MIMO antenna for detecting oedema in human knee</p>
<p><strong>Article References:</strong> Sabarish, J. G., &amp; Das, P. (2026). A wearable circularly polarised MIMO antenna for detecting oedema in human knee. <em>Results in Engineering, 32</em>, Article 113435. <a href="https://doi.org/10.1016/j.rineng.2026.113435" rel="noopener noreferrer">https://doi.org/10.1016/j.rineng.2026.113435</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1016/j.rineng.2026.113435" rel="noopener noreferrer">10.1016/j.rineng.2026.113435</a></p>
<p><strong>Keywords:</strong> wearable antenna, MIMO, circular polarisation, oedema detection, frequency-selective surface, biomedical sensing, jeans substrate, axial ratio bandwidth, SAR, knee phantom, body-centric communication, microwave imaging</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">265139</post-id>	</item>
		<item>
		<title>One Stealthy Skin to Fool Infrared, Radar, and Microwave Sensors at Once</title>
		<link>https://scienmag.com/one-stealthy-skin-to-fool-infrared-radar-and-microwave-sensors-at-once/</link>
		
		<dc:creator><![CDATA[Denise Maddox]]></dc:creator>
		<pubDate>Fri, 02 Oct 2026 21:52:05 +0000</pubDate>
				<category><![CDATA[Technology and Engineering]]></category>
		<category><![CDATA[advanced composite materials for stealth]]></category>
		<category><![CDATA[brightness temperature]]></category>
		<category><![CDATA[electromagnetic absorption]]></category>
		<category><![CDATA[electromagnetic spectrum camouflage]]></category>
		<category><![CDATA[engineered structures for battlefield stealth]]></category>
		<category><![CDATA[frequency-selective surface]]></category>
		<category><![CDATA[infrared emissivity]]></category>
		<category><![CDATA[infrared radar microwave stealth technology]]></category>
		<category><![CDATA[integrated sensor spoofing devices]]></category>
		<category><![CDATA[Kirchhoff's law]]></category>
		<category><![CDATA[meta-absorber]]></category>
		<category><![CDATA[Metamaterials]]></category>
		<category><![CDATA[microwave radiometry]]></category>
		<category><![CDATA[microwave radiometry concealment]]></category>
		<category><![CDATA[multi-channel detection countermeasures]]></category>
		<category><![CDATA[multifunctional meta-absorber for sensor evasion]]></category>
		<category><![CDATA[multispectral camouflage]]></category>
		<category><![CDATA[ohmic loss]]></category>
		<category><![CDATA[passive electromagnetic signature suppression]]></category>
		<category><![CDATA[radar cross section]]></category>
		<category><![CDATA[radar wave absorption materials]]></category>
		<category><![CDATA[sensor fusion resistant camouflage]]></category>
		<category><![CDATA[stealth materials]]></category>
		<category><![CDATA[thermal infrared signature reduction]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=229211</guid>

					<description><![CDATA[Researchers at Central South University have demonstrated a layered meta-absorber that simultaneously suppresses infrared emission, cuts radar cross section by 10 dB, and reduces microwave brightness temperature contrast by over 40 percent for multispectral camouflage.]]></description>
										<content:encoded><![CDATA[<p>Modern battlefields no longer rely on a single pair of eyes. High-value ground assets such as command vehicles, radar stations, and missile launchers are now tracked by fused suites of sensors that span the electromagnetic spectrum: thermal cameras reading infrared signatures, radars sweeping for echoes, and microwave radiometers passively measuring the natural microwave glow of objects against their surroundings. A material that hides a target from one of these channels often makes it stand out in another, which is precisely why most conventional camouflage coatings fall short. A team at Central South University in Changsha, China, now reports a single engineered structure designed to defeat all three detection channels simultaneously, and they have demonstrated it both in simulation and in physical prototypes.</p>
<p>The new device, described in the journal Advanced Composites and Hybrid Materials, is called a multifunctional meta-absorber. It is built from two stacked functional layers, each with a carefully assigned job. The top layer is an infrared shielding layer, implemented as a frequency-selective surface, and its task is to suppress the thermal signature of whatever sits beneath it. The bottom layer is a radar absorption and microwave emissivity layer, a multilayer stacked structure that swallows incoming radar waves while radiating strongly in the microwave band. The elegance of the design lies in how these two layers divide the spectrum between them without interfering with each other&#8217;s work.</p>
<p>Start with the infrared problem. Every object warmer than absolute zero emits thermal radiation, and in the infrared atmospheric windows this emission is what thermal imagers detect. Metals are notoriously conspicuous in these bands because they behave almost like perfect infrared mirrors with very high effective emissivity contrast against natural backgrounds once heated. The researchers tackled this with their frequency-selective surface, which is engineered to present a low infrared emissivity of just 0.334. In practical terms, the surface emits only about a third of the thermal radiation that a conventional surface at the same temperature would, dramatically shrinking the thermal contrast that an infrared camera would register.</p>
<p>Crucially, that infrared shielding cannot come at the cost of blocking the layers below. Many materials that suppress infrared emission, such as continuous metallic films, also reflect or absorb microwaves, which would ruin the radar and radiometric performance of the underlying structure. The frequency-selective surface solves this by being spatially patterned rather than continuous: it behaves differently at different frequencies and for different propagation directions, remaining essentially transparent to microwaves while still delivering its low-emissivity thermal behavior. This frequency-selective transparency is what allows a single laminate to serve two masters at once, a constraint that has long limited multispectral camouflage designs.</p>
<p>The second layer carries the microwave burden, and it does so through a mechanism as old as electrical engineering itself: ohmic loss. When an electromagnetic wave enters a lossy conductor, the induced currents dissipate its energy as heat rather than allowing it to reflect back toward the source. By stacking multiple layers with tuned properties, the team created a structure that achieves broadband absorption exceeding 90 percent across the range from 4.62 to 28.29 gigahertz. That span covers much of the radar spectrum used for detection and tracking, from lower-frequency surveillance bands through the higher frequencies favored by modern fire-control and imaging radars.</p>
<p>Broadband absorption translates directly into a smaller radar cross section, the measure of how visible a target is to radar. In their experiments, the meta-absorber achieved a 10 dB reduction in radar cross section across the band from 4.38 to 21.18 gigahertz. A 10 dB reduction means the returning echo carries only one-tenth of the power it otherwise would, which can shrink the detection range a radar achieves against the target by a substantial margin. The researchers also report that the structure maintains its performance over wide angles of incidence and is insensitive to polarization, meaning it cannot be defeated simply by illuminating the target from an oblique angle or with a differently oriented antenna.</p>
<p>The most conceptually interesting part of the work addresses microwave radiometric detection, a passive technique that is increasingly being folded into integrated sensor suites. Unlike radar, a radiometer emits nothing; it simply listens, measuring the microwave brightness temperature of the scene. Kirchhoff&#8217;s law of thermal radiation ties together absorption and emission: a body that absorbs strongly at a given frequency must also emit strongly there. Metals, being poor emitters at microwave frequencies, appear cold against the warm microwave background of the natural environment, and that cold spot betrays them to a radiometer even when their radar echo has been suppressed.</p>
<p>Here the meta-absorber turns an apparent conflict into an advantage. Because the radar-absorbing layer is designed to absorb more than 90 percent of incident microwave radiation, Kirchhoff&#8217;s law dictates that it also emits strongly in the same band. Instead of appearing as a cold metallic anomaly, the coated target radiates at a brightness temperature close to that of its surroundings, blending into the radiometric background. The team quantified this effect: the average brightness temperature contrast between a metallic target and its background fell by 40.33 percent when the meta-absorber was applied. In other words, the very loss mechanism that hides the target from radar simultaneously camouflages it from passive microwave sensors, resolving a trade-off that has plagued earlier single-purpose designs.</p>
<p>Taken together, the reported properties form an unusually complete camouflage package: low infrared emissivity, high microwave absorptivity, high microwave emissivity, wide-angle stability, and polarization insensitivity, all in a layered structure that can be fabricated and tested experimentally rather than existing only in simulation. The authors argue that this combination offers a viable route to protecting high-value ground targets against the integrated, multispectral detection systems that are becoming the norm rather than the exception. The work was supported by the National Natural Science Foundation of China, the Natural Science Foundation of Hunan Province, and the Fundamental Research Funds for the Central Universities of Central South University.</p>
<p>The broader significance of the study lies in its systems-level thinking. Stealth research has historically optimized one spectral channel at a time, often leaving targets exposed to whichever sensor the designer ignored. As detection platforms fuse infrared imaging, active radar, and passive radiometry into a single kill chain, camouflage must become equally multispectral, and the physics of that task is unforgiving because absorption, emission, and reflection are bound together by thermodynamic law. By exploiting those very laws, using a frequency-selective surface to decouple infrared from microwave behavior and ohmic loss to couple radar absorption to radiometric emission, the Central South University team has shown that the constraints can be turned into design tools. If such meta-absorbers can be manufactured at scale, on flexible substrates, and with the durability that fielded equipment demands, the era of hiding in plain sight across the entire spectrum may be moving from theory toward hardware.</p>
<p><strong>Subject of Research:</strong> Multispectral camouflage metamaterials that counter infrared, radar, and microwave radiometric detection</p>
<p><strong>Article Title:</strong> Multifunctional meta-absorber for multispectral camouflage against infrared, radar, and microwave radiometric detection</p>
<p><strong>Article References:</strong> Wu, R., Dong, J., Xiao, C., Wang, M., &amp; Luo, H. (2026). Multifunctional meta-absorber for multispectral camouflage against infrared, radar, and microwave radiometric detection. <em>Advanced Composites and Hybrid Materials</em>. <a href="https://doi.org/10.1007/s42114-026-02108-8" rel="noopener noreferrer">https://doi.org/10.1007/s42114-026-02108-8</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1007/s42114-026-02108-8" rel="noopener noreferrer">10.1007/s42114-026-02108-8</a></p>
<p><strong>Keywords:</strong> meta-absorber, metamaterials, multispectral camouflage, infrared emissivity, radar cross section, microwave radiometry, brightness temperature, frequency-selective surface, ohmic loss, stealth materials, Kirchhoff&#x27;s law, electromagnetic absorption</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">229211</post-id>	</item>
	</channel>
</rss>
