<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>environmental security testing for Bacillus anthracis &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/environmental-security-testing-for-bacillus-anthracis/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Sun, 13 Sep 2026 02:50:06 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>environmental security testing for Bacillus anthracis &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>Cobalt-Based MOF Sensor Detects Anthrax Biomarker in Water in One Minute</title>
		<link>https://scienmag.com/cobalt-based-mof-sensor-detects-anthrax-biomarker-in-water-in-one-minute/</link>
		
		<dc:creator><![CDATA[Bethany Barker]]></dc:creator>
		<pubDate>Sun, 13 Sep 2026 02:50:06 +0000</pubDate>
				<category><![CDATA[Chemistry]]></category>
		<category><![CDATA[affordable and quick alternatives to chromatography for pathogen detection]]></category>
		<category><![CDATA[anthrax]]></category>
		<category><![CDATA[Bacillus anthracis]]></category>
		<category><![CDATA[biosensor]]></category>
		<category><![CDATA[bioterrorism detection]]></category>
		<category><![CDATA[bioterrorism threat detection in drinking water]]></category>
		<category><![CDATA[cobalt]]></category>
		<category><![CDATA[Cobalt-based MOF sensor for rapid anthrax detection in water]]></category>
		<category><![CDATA[detection of anthrax biomarkers in water]]></category>
		<category><![CDATA[dipicolinic acid]]></category>
		<category><![CDATA[drinking water]]></category>
		<category><![CDATA[environmental security testing for Bacillus anthracis]]></category>
		<category><![CDATA[fast waterborne pathogen screening technologies]]></category>
		<category><![CDATA[fluorescence quenching]]></category>
		<category><![CDATA[fluorescence sensing]]></category>
		<category><![CDATA[fluorescent probe for dipicolinic acid in water analysis]]></category>
		<category><![CDATA[innovative chemical sensors for anthrax spores]]></category>
		<category><![CDATA[metal-organic framework]]></category>
		<category><![CDATA[metal-organic frameworks for biothreat detection]]></category>
		<category><![CDATA[nanosensor]]></category>
		<category><![CDATA[public health water safety monitoring]]></category>
		<category><![CDATA[water contamination detection using MOFs]]></category>
		<category><![CDATA[Water Safety]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=201020</guid>

					<description><![CDATA[Researchers have created a cobalt-based metal-organic framework that fluorescently detects the anthrax biomarker dipicolinic acid in drinking water within one minute, matching HPLC accuracy.]]></description>
										<content:encoded><![CDATA[<p>A cobalt-based metal-organic framework that can flag the chemical fingerprint of anthrax spores in drinking water within a single minute has been developed by researchers seeking a faster, cheaper alternative to laboratory chromatography. The material, described in the journal Results in Chemistry, acts as a fluorescent probe that dims sharply in the presence of dipicolinic acid, a small molecule that makes up roughly 10 to 15 percent of the dry weight of Bacillus anthracis spores and serves as one of the most reliable chemical signatures of the pathogen. Because anthrax spores can persist in harsh environments for decades and the bacterium carries a dual threat as both a disease agent and a potential bioterrorism weapon, rapid water screening has long been a priority for public health and security agencies alike.</p>
<p>The motivation behind the work stems from a sobering global picture. The World Health Organization estimates that approximately 1.4 million people die each year from waterborne diseases, and bacterial contamination of drinking water remains among the most consequential water quality threats, with implications spanning public health, environmental stability, and national security. Conventional analytical techniques for detecting dipicolinic acid include high-performance liquid chromatography, mass spectrometry, surface-enhanced Raman spectroscopy, electrochemical methods, and immunoassays. While several of these approaches achieve impressive sensitivity, they typically demand sophisticated instrumentation, specialized substrates or electrodes, and laborious sample preparation, all of which limit their usefulness for rapid, high-throughput screening in the field or in resource-constrained settings.</p>
<p>Fluorescent metal-organic frameworks, or MOFs, have emerged as a compelling alternative. These crystalline materials are built from metal nodes connected by organic linkers, forming porous architectures whose photoluminescence can be switched off, or quenched, when a target molecule binds inside. Many previously reported DPA sensors have relied on lanthanide metals such as europium and terbium, which are expensive and often require intricate multi-step syntheses. The research team, led by Mohammad Rezvani Ghalhari with Kamyar Yaghmaeian and Ghader Ghanizadeh, chose cobalt instead, citing its greater availability, high stability in aquatic environments, and suitability for fluorescence-based pollutant detection.</p>
<p>The synthesis itself was deliberately straightforward. Cobalt nitrate hexahydrate and 2,2&#8242;-diamino-4,4&#8242;-biphenyldicarboxylic acid were dissolved in a water and dimethylformamide mixture, sonicated, sealed in a Teflon-lined stainless-steel autoclave, and heated at 150 degrees Celsius for six hours under autogenous pressure. The resulting crystalline powder was collected by centrifugation, washed repeatedly to remove unreacted precursors, and vacuum dried. A battery of characterization techniques confirmed the material&#8217;s quality. Field-emission scanning electron microscopy revealed well-defined polyhedral particles with triangular to hexagonal prismatic shapes, smooth flat surfaces, and sharp edges, evidence of controlled nucleation and growth. Energy-dispersive X-ray spectroscopy verified the incorporation of cobalt into the organic framework without detectable impurities.</p>
<p>Structural analysis reinforced the picture of a well-formed sensor platform. Powder X-ray diffraction showed sharp peaks at 2-theta values of approximately 10, 19, and 24 degrees, corresponding to the (100), (200), and (210) crystal planes of a highly ordered porous framework, with the absence of amorphous halos indicating high phase purity. Fourier-transform infrared spectroscopy identified the functional groups of the aminated biphenyl dicarboxylic acid linker and, crucially, a band at 630 wavenumbers assigned to Co-O stretching, direct spectroscopic evidence that cobalt centers had coordinated with the carboxylate oxygen atoms. Thermogravimetric analysis showed the framework remained stable up to about 300 degrees Celsius, far beyond the ambient conditions of any water-sensing application.</p>
<p>With the material characterized, the team optimized the sensing conditions. Fluorescence measurements, taken with excitation at 332 nanometers and emission monitored at 425 nanometers, peaked at neutral pH 7, which conveniently matches the natural pH of drinking water. Under acidic conditions, DPA becomes protonated and the framework&#8217;s carboxylate linkers risk partial protonation, both of which suppress the response. The optimal sensor concentration proved to be 50 milligrams per liter; below that, signals were weak because too few fluorescent centers were available, while above it the intensity plateaued as the system saturated. Most strikingly, the interaction between DPA and the probe reached equilibrium within just one minute of contact, faster than the three-minute reaction time reported for comparable europium-based sensors.</p>
<p>Under these optimized conditions, the sensor delivered strong analytical performance across a linear range of 0 to 100 micromolar, with a correlation coefficient of 0.9891. The limit of detection was 0.089 micromolar and the limit of quantification 0.271 micromolar, figures competitive with many lanthanide-based MOF probes reported previously. At the highest tested DPA concentration, the emission intensity fell to roughly 55 percent of its original value, a pronounced turn-off response. Selectivity testing against common drinking water ions, including potassium, sodium, magnesium, calcium, chloride, phosphate, and sulfate, as well as structural analogs such as picolinic acid, 2,4-pyridinedicarboxylic acid, and benzoic acid, produced essentially no quenching, confirming that the sensor responds specifically to DPA. Stored in the dark at room temperature, the material retained the vast majority of its luminescence over 90 days.</p>
<p>The team also dissected the photophysical mechanism behind the quenching. Förster resonance energy transfer was ruled out because DPA absorbs only in the deep ultraviolet, below 280 nanometers, while the MOF emits at 425 nanometers, leaving no meaningful spectral overlap. The inner filter effect was likewise excluded because the excitation wavelength falls outside DPA&#8217;s absorption envelope. Instead, the evidence points to coordination-induced static quenching, potentially accompanied by photoinduced electron transfer. DPA is an effective tridentate ligand, chelating the open cobalt(II) sites through its pyridine nitrogen and two carboxylate groups to form a stable ground-state complex. Its electron-deficient character then allows it to act as an electron sink, drawing photoexcited electrons away from the framework and suppressing radiative recombination, which manifests as rapid fluorescence loss.</p>
<p>Practical validation followed two tracks. In spiked real water samples, the sensor&#8217;s recoveries ranged from 97.31 to 101.68 percent with relative standard deviations between 0.13 and 1.49 percent, statistically indistinguishable from results obtained by high-performance liquid chromatography, whose recoveries spanned 99.1 to 100.27 percent. Calculated p-values all exceeded 0.05, confirming no significant difference between the two methods. In a diagnostic validation involving 48 cultured water samples, 24 inoculated with Bacillus anthracis and 24 with Escherichia coli as negatives, the sensor achieved 92 percent sensitivity, 95.6 percent specificity, a positive predictive value of 95.8 percent, a negative predictive value of 91.6 percent, and an overall accuracy of 93.75 percent. The authors note that high sensitivity is critical for biosecurity, where missed detections carry severe consequences, while high specificity minimizes false alarms that could trigger unnecessary emergency responses.</p>
<p>The researchers conclude that the cobalt-based framework offers a rapid, cost-effective, and reliable tool for anthrax biomarker monitoring in real water samples, combining a one-minute response, a detection limit rivaling lanthanide systems, and stability suitable for extended practical use. By swapping rare and costly metals for abundant cobalt and a simple hydrothermal recipe, the study lowers a significant barrier to deploying fluorescent MOF sensors outside specialized laboratories. As concerns about water safety and biodefense continue to intersect, sensors of this kind could become a routine first line of screening, flagging contaminated supplies in minutes and reserving slower, instrument-heavy confirmatory methods for the samples that truly warrant them.</p>
<p><strong>Subject of Research:</strong> A cobalt-based metal-organic framework fluorescent sensor for rapid detection of dipicolinic acid as a Bacillus anthracis biomarker in drinking water</p>
<p><strong>Article Title:</strong> A Co-based MOF for rapid and facile fluorescent detection of dipicolinic acid as an anthrax biomarker</p>
<p><strong>Article References:</strong> Ghalhari, M. R., Yaghmaeian, K., &amp; Ghanizadeh, G. (2026). A Co-based MOF for rapid and facile fluorescent detection of dipicolinic acid as an anthrax biomarker. <em>Results in Chemistry, 30</em>, Article 103826. <a href="https://doi.org/10.1016/j.rechem.2026.103826" rel="noopener noreferrer">https://doi.org/10.1016/j.rechem.2026.103826</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1016/j.rechem.2026.103826" rel="noopener noreferrer">10.1016/j.rechem.2026.103826</a></p>
<p><strong>Keywords:</strong> metal-organic framework, cobalt, dipicolinic acid, anthrax, Bacillus anthracis, fluorescence sensing, water safety, biosensor, bioterrorism detection, drinking water, nanosensor, fluorescence quenching</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">201020</post-id>	</item>
	</channel>
</rss>
