<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>energy-efficient data center design &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/energy-efficient-data-center-design/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Wed, 26 Aug 2026 18:40:30 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.2</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>energy-efficient data center design &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>Data Centers Could Recycle Waste Heat for Cooling Using Adsorption Heat Pumps</title>
		<link>https://scienmag.com/data-centers-could-recycle-waste-heat-for-cooling-using-adsorption-heat-pumps/</link>
		
		<dc:creator><![CDATA[Sloane Callahan]]></dc:creator>
		<pubDate>Wed, 26 Aug 2026 18:40:30 +0000</pubDate>
				<category><![CDATA[Climate]]></category>
		<category><![CDATA[adsorption heat pump technology for cooling]]></category>
		<category><![CDATA[artificial intelligence impact on data center energy use]]></category>
		<category><![CDATA[Data center waste heat recycling]]></category>
		<category><![CDATA[energy-efficient data center design]]></category>
		<category><![CDATA[environmentally friendly data center cooling methods]]></category>
		<category><![CDATA[global energy consumption of data centers]]></category>
		<category><![CDATA[heat reuse in cloud computing infrastructure]]></category>
		<category><![CDATA[heat-to-cooling conversion systems]]></category>
		<category><![CDATA[high-capacity heat recovery systems]]></category>
		<category><![CDATA[reducing data center carbon footprint]]></category>
		<category><![CDATA[sustainable data center cooling solutions]]></category>
		<category><![CDATA[thermal energy recovery in data centers]]></category>
		<guid isPermaLink="false">https://scienmag.com/data-centers-could-recycle-waste-heat-for-cooling-using-adsorption-heat-pumps/</guid>

					<description><![CDATA[The world’s data centers are becoming giant furnaces—and researchers now propose using that heat to make more cooling. A study led by engineers Jinkyun Cho and Joo Hyun Moon describes a “cooling-from-cooling” system that captures heat from liquid-immersed computer hardware and feeds it into an adsorption heat pump. The device then produces chilled water for [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>The world’s data centers are becoming giant furnaces—and researchers now propose using that heat to make more cooling. A study led by engineers Jinkyun Cho and Joo Hyun Moon describes a “cooling-from-cooling” system that captures heat from liquid-immersed computer hardware and feeds it into an adsorption heat pump. The device then produces chilled water for cooling other equipment, creating a thermal recycling loop designed to reduce dependence on electrically driven cooling machinery. In a prototype-scale design, 50 kilowatts of heat recovered from a 200-kilowatt immersion-cooling system would generate approximately 20 kilowatts of additional cooling. The concept could offer data-center operators a way to expand computing capacity while making use of heat that would otherwise be rejected to the atmosphere.</p>
<p>The proposal arrives as artificial intelligence, cloud computing and connected devices drive an extraordinary expansion in computing infrastructure. Data centers consumed an estimated 240–340 terawatt-hours of electricity in 2022, equivalent to roughly 1–1.3 percent of global electricity use, according to the International Energy Agency. That demand is expected to more than double by 2030. Although electricity powers the processors, memory and networking equipment, nearly all of the energy consumed by information technology ultimately becomes heat. Keeping that heat away from sensitive electronics can account for about 30–40 percent of a facility’s energy use under some operating conditions. Conventional systems move heat into chilled water or exhaust air, then reject it through cooling towers or dry coolers. Much of the thermal energy is therefore lost despite being continuously available.</p>
<p>The challenge is not simply the amount of heat, but its temperature and thermodynamic quality. Traditional air-cooled servers generally release heat at only about 35–45 °C, while condenser-water loops may return at around 37 °C. That is abundant energy, but it is “low grade”: its temperature is too close to the surrounding environment to drive many useful heat engines or industrial processes. Warm-water liquid cooling can raise the outlet temperature to roughly 50–65 °C, and two-phase systems may reach 70–90 °C, but these more advanced technologies introduce engineering concerns involving leakage, vapor distribution, reliability and long-term stability. The researchers identify an intermediate range of approximately 45–60 °C as the most practical for their approach. It is hot enough to regenerate an adsorption cycle, yet compatible with liquid cooling systems that can keep high-power processors within safe operating limits.</p>
<p>An adsorption heat pump does not use a mechanically compressed refrigerant in the way a conventional electric chiller does. Instead, it relies on the ability of a porous solid to attract and release a refrigerant, in this case water vapor, as its temperature changes. The proposed machine contains two beds of adsorbent material, a condenser and an evaporator. While one bed is heated, or regenerated, hot water drives water vapor out of the material. That vapor condenses, and the liquid refrigerant then evaporates at low pressure, absorbing heat from a chilled-water loop. The evaporator thereby produces cooling. At the same time, the second bed adsorbs vapor and releases heat to cooling water. The two beds periodically switch roles, allowing the cycle to continue. Because the regeneration energy comes from data-center waste heat, the system can produce cooling without adding a compressor or requiring an electrically powered heat-up stage.</p>
<p>To test whether the cycle could function with data-center heat, the researchers modeled two adsorbent–water pairs: silica gel–water and MIL-101(Cr)–water. Their calculations used a Linear Driving Force model, a standard approximation for transient adsorption and desorption. In that model, the rate at which refrigerant is taken up or released depends on the difference between the material’s instantaneous uptake and its equilibrium uptake. The model also included the heat released during adsorption, the heat required for desorption, the thermal masses of the bed and adsorbent, and the temperatures and flow rates of the working fluids. The coupled equations were solved with adaptive numerical time stepping because the cycle involves rapidly changing, nonlinear interactions between heat and mass transfer. A cycle time of about 200 seconds produced stable behavior in the simulation.</p>
<p>The modeled system used hot water entering the adsorption beds at 53 °C and cooling water entering at 32 °C. Under these conditions, the silica-gel system delivered a coefficient of performance, or COP, of about 0.77 in the reported calculation. COP is the ratio of cooling delivered to thermal energy supplied; it is not directly comparable to the COP of an electric compressor because the energy input is primarily heat rather than electricity. The model showed that raising the regeneration temperature could actually reduce performance: silica gel’s COP fell to 0.27 at 63 °C and 0.17 at 73 °C. The researchers attribute this decline to greater refrigerant uptake and larger enthalpy flows during short cycles, increasing the thermal input required for each unit of cooling. The MIL-101(Cr)–water pair produced COP values of approximately 0.25–0.40 and showed stronger adsorption potential at lower cold-bed temperatures. These results suggest that choosing the adsorbent and operating temperature together will be crucial.</p>
<p>The proposed engineering configuration combines six immersion tanks, two coolant distribution units, an adsorption heat pump and a rear-door heat exchanger. The immersion system is designed for a 200-kilowatt information-technology load, with each tank handling about 34 kilowatts. One 50-kilowatt section of the cooling loop sends hot coolant to the adsorption heat pump, while a separate 150-kilowatt section continues to the cooling tower. The recovered heat enters the heat pump at approximately 53 °C and leaves at about 48 °C. The resulting 20-kilowatt chilled-water output leaves the evaporator at 20 °C and is sent to a rear-door heat exchanger serving an additional 18-kilowatt air-cooled load. Pumps, fans and heat exchangers were sized with allowances for flow resistance and piping losses. The design therefore does not claim that all data-center heat can be converted into cooling; rather, it diverts a carefully selected fraction into a thermal cycle while the remaining heat follows the conventional rejection path.</p>
<p>The energy analysis produced a more complicated result than a simple claim of universal electricity savings. Compared with immersion cooling alone, the internal-reuse configuration required additional pumps, a heat exchanger and a rear-door fan. At full design load, the baseline system had a mechanical load component of 0.051 and a cooling-focused power usage effectiveness, or PUE, of 1.051. With heat recovery used internally, those values increased to 0.065 and 1.065 because the extra equipment consumed mechanical energy. However, the same configuration enabled the facility to cool an additional 18-kilowatt air-cooled information-technology load, raising the total modeled IT load from 200 to 218 kilowatts without adding compressor power. In a second scenario, where recovered heat was credited against an external cooling demand, the calculated mechanical load component fell to 0.031 and PUEcooling to 1.031. The distinction matters: recycling heat within the facility can increase cooling capacity even when it does not reduce the cooling system’s own electricity use, while exporting the recovered thermal benefit can improve the accounting efficiency more directly.</p>
<p>The study is a theoretical and prototype-scale demonstration rather than proof of commercial performance. Its calculations assume continuous operation at full rated load for 8,760 hours per year, whereas real computing demand fluctuates and cooling towers perform differently across climates and seasons. Adsorption machines also tend to have lower COPs and slower dynamic responses than mechanical chillers, and maintaining a stable 200-second switching cycle under changing server loads may be difficult. The researchers say a pilot system is being developed for experimental validation, including tests of operating stability, thermal matching and real-world energy consumption. If those tests confirm the model, the approach could be especially valuable in high-density computing facilities where cooling capacity—not processor availability—is becoming the main limit on expansion. Rather than treating waste heat as an unwanted by-product, the system turns it into a second chance to remove heat, closing a loop that could help data centers handle the escalating thermal burden of artificial intelligence.</p>
<div class="scienmag-article-metadata">
<p><strong>Subject of Research:</strong> Recycling liquid-cooled data-center waste heat to produce additional cooling through an adsorption heat pump</p>
<p><strong>Article Title:</strong> Cooling-from-cooling: Data-center waste-heat recovery using an adsorption heat pump</p>
<p><strong>Article References:</strong> Cho, J. and Moon, J.H., original research source supplied without a publication URL <a href="https://www.sciencedirect.com/science/article/pii/S2352484726005597?dgcid=rss_sd_all" target="_blank" rel="noopener noreferrer">Original publication</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1016/j.egyr.2026.109590" target="_blank" rel="noopener noreferrer">10.1016/j.egyr.2026.109590</a></p>
<p><strong>Keywords:</strong> data-center cooling, waste-heat recovery, adsorption heat pump, immersion cooling, liquid cooling, artificial intelligence infrastructure, energy efficiency, power usage effectiveness</p>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">182393</post-id>	</item>
		<item>
		<title>Exploring the Role of Data Center Planning in Mitigating Carbon Emissions: A Case Study from China</title>
		<link>https://scienmag.com/exploring-the-role-of-data-center-planning-in-mitigating-carbon-emissions-a-case-study-from-china/</link>
		
		<dc:creator><![CDATA[Sloane Callahan]]></dc:creator>
		<pubDate>Wed, 26 Mar 2025 17:04:30 +0000</pubDate>
				<category><![CDATA[Chemistry]]></category>
		<category><![CDATA[artificial intelligence energy consumption]]></category>
		<category><![CDATA[carbon emissions reduction strategies]]></category>
		<category><![CDATA[carbon-oriented demand response]]></category>
		<category><![CDATA[China carbon footprint case study]]></category>
		<category><![CDATA[data center planning]]></category>
		<category><![CDATA[energy-efficient data center design]]></category>
		<category><![CDATA[green data center initiatives]]></category>
		<category><![CDATA[impact of AI on energy demands]]></category>
		<category><![CDATA[location-based carbon mitigation]]></category>
		<category><![CDATA[operational flexibility in data centers]]></category>
		<category><![CDATA[renewable energy optimization]]></category>
		<category><![CDATA[sustainable computing practices]]></category>
		<guid isPermaLink="false">https://scienmag.com/exploring-the-role-of-data-center-planning-in-mitigating-carbon-emissions-a-case-study-from-china/</guid>

					<description><![CDATA[The emergence of artificial intelligence (AI) technology has catalyzed profound shifts in computational demands across the globe, with data centers bearing the brunt of this transformation in terms of energy consumption and, consequently, carbon emissions. As AI applications grow increasingly sophisticated, they necessitate greater computational capacity, leading to a notable surge in the energy footprint [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>The emergence of artificial intelligence (AI) technology has catalyzed profound shifts in computational demands across the globe, with data centers bearing the brunt of this transformation in terms of energy consumption and, consequently, carbon emissions. As AI applications grow increasingly sophisticated, they necessitate greater computational capacity, leading to a notable surge in the energy footprint of data centers. This study dives deep into the implications of such trends, particularly in the context of China, unveiling the potential for significant carbon emission reductions through strategic planning and execution.</p>
<p>Central to the investigation is the concept of carbon-oriented demand response. This approach focuses on optimizing the operations of data centers in a manner that aligns with the availability of renewable energy sources, thus ensuring that energy consumption coincides with times when clean energy generation is at its peak. Through this lens, the research advocates for a reevaluation of where and how data centers are established, recommending the relocation of operations to less carbon-intensive regions. By doing so, the study underscores the importance of both location and operational flexibility in mitigating environmental impacts.</p>
<p>The empirical findings of the study are both compelling and actionable. They suggest that by strategically positioning new data centers in regions such as Gansu Province, Ningxia Hui Autonomous Region, Sichuan Province, Inner Mongolia Autonomous Region, and Qinghai Province, a considerable reduction in carbon emissions can be achieved. Together, these areas are expected to accommodate 57% of the anticipated national surge in server capacity. This geographical redistribution not only addresses local energy needs more sustainably but also illustrates the efficacy of data center planning that takes into account carbon emissions.</p>
<p>In the detailed analysis, the study reveals that a significant portion of the computational load currently located in Eastern China could be effectively transferred to Western regions. This load shift, equating to about 33% of the total computational demand from the east, is projected to yield a remarkable reduction of 26% in overall carbon emissions at the national level. Such a drastic decline underscores the potential for data centers to operate in a manner that is not merely profitable but also sustainable.</p>
<p>Dr. Bojun Du, a leading researcher in the study, emphasizes the critical need for a carbon-oriented approach to data center planning. By adopting models that consider the temporal and spatial flexibility of computational loads, the quality of service can also be maintained without exacerbating carbon outputs. This holistic perspective on data center management illustrates the synergy between technological advancement and environmental responsibility, paving the way for a future where AI-driven infrastructure coexists with sustainable energy practices.</p>
<p>As the demand for data processing escalates, the geographical implications become particularly significant. Data centers located in Western China, endowed with renewable energy resources, are deemed optimal for handling batch loads, whereas those in the East are tailored for real-time online processing. This dichotomy highlights the necessity of a carefully coordinated strategy that not only addresses immediate computational needs but also aligns with long-term environmental goals.</p>
<p>The potential for carbon emission reduction through carbon-oriented demand response models is unmistakable. The research indicates that 83% of the national computational demand originates from the Eastern region, with only 17% accounting for the West. However, as the study illustrates, effective load balancing could lead to substantial emissions reductions while simultaneously leveraging the renewable energy capacities of the Western regions.</p>
<p>Notably, the findings indicate that while significant loads are transferred away from high-emission Eastern China, there is also an expected uptick in emissions within certain Western areas, due to the disparity in energy consumption patterns. This dual impact calls for nuanced policy discussions and energy management practices that recognize both the benefits and challenges of shifting loads geographically.</p>
<p>Furthermore, the publication of this research in a well-regarded open-access journal underscores the importance of making such critical findings widely available to academics and policy-makers alike. By fostering an understanding of innovative solutions to the environmental challenges posed by data centers, the study contributes to the ongoing discourse surrounding energy sustainability in the digital age.</p>
<p>Publishing research outcomes in top-tier journals represents a step towards bridging the gap between academic insights and practical applications in energy management. The rapid evolution of AI technologies can benefit from ongoing collaboration between researchers, industry professionals, and policymakers, ensuring that the pursuit of technological advancement does not come at the expense of ecological health.</p>
<p>In conclusion, as AI continues to redefine the landscape of data processing, the insights from this study illuminate the pathway toward more sustainable practices. These findings reveal that with informed planning and strategic relocation of computational loads, the environmental impact of data centers can be significantly mitigated. Such actions pave the way for a greener, more sustainable future in data management.</p>
<p>This research not only highlights the pressing issues surrounding carbon emissions related to data centers but also provides a strategic framework for mitigating these impacts through innovative operational models. The collaboration of energy management strategies and technological advancements represents a proactive step in addressing the urgent environmental challenges of our times.</p>
<p>&#8212;<br />
I refrained from adding sections like references or keywords since you requested only to focus on the news article. If you need further details or specific formatting, let me know!</p>