<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>closed-loop therapy &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/closed-loop-therapy/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Wed, 21 Oct 2026 05:47:12 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>closed-loop therapy &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>Research report: Translational Barriers and AI‐Driven Challenges of Microfluidics‐Enabled Wearables and Implantable Systems in Personalized Medicine</title>
		<link>https://scienmag.com/research-report-translational-barriers-and-ai%e2%80%90driven-challenges-of-microfluidics%e2%80%90enabled-wearables-and-implantable-systems-in-personalized-medicine/</link>
		
		<dc:creator><![CDATA[Eric Holt]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 05:47:12 +0000</pubDate>
				<category><![CDATA[Technology and Engineering]]></category>
		<category><![CDATA[AI and microfluidics integration in point-of-care diagnostics]]></category>
		<category><![CDATA[AI-driven personalized healthcare]]></category>
		<category><![CDATA[algorithmic bias]]></category>
		<category><![CDATA[Artificial Intelligence]]></category>
		<category><![CDATA[barriers]]></category>
		<category><![CDATA[biocompatibility]]></category>
		<category><![CDATA[biofluid sensing]]></category>
		<category><![CDATA[biological fluid analysis]]></category>
		<category><![CDATA[Clinical validation]]></category>
		<category><![CDATA[clinical validation of microfluidic devices]]></category>
		<category><![CDATA[closed-loop therapy]]></category>
		<category><![CDATA[closed-loop treatment systems]]></category>
		<category><![CDATA[continuous biosensing systems]]></category>
		<category><![CDATA[digital health]]></category>
		<category><![CDATA[implantable biosensors]]></category>
		<category><![CDATA[implantable medical devices]]></category>
		<category><![CDATA[microfluidic wearables]]></category>
		<category><![CDATA[microfluidics-enabled wearables]]></category>
		<category><![CDATA[miniature fluid handling technology]]></category>
		<category><![CDATA[overcoming translational barriers in personalized medicine]]></category>
		<category><![CDATA[Personalized Medicine]]></category>
		<category><![CDATA[scalable manufacturing of implantable systems]]></category>
		<category><![CDATA[Translational]]></category>
		<category><![CDATA[wearable glucose and lactate monitoring]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=327258</guid>

					<description><![CDATA[A review finds that AI-enabled microfluidic wearables and implants could support continuous personalized monitoring, but clinical adoption requires stable materials, unbiased algorithms, interoperable systems and rigorous validation.]]></description>
										<content:encoded><![CDATA[<p>A review of microfluidics-enabled wearable and implantable medical technologies finds that miniature fluid handling, biosensing and artificial intelligence are converging into experimental systems for continuous, personalized monitoring. Microfluidic platforms can collect and analyze microliter- to nanoliter-scale samples of sweat, tears, interstitial fluid or blood, while AI can compensate for noisy readings, interpret time-series data and support closed-loop treatment. The hardware has already enabled experimental monitoring of glucose, lactate, hormones, pathogens and wound biomarkers, but most systems remain at the prototype stage.</p>
<p>Translation into routine care depends on rigorous clinical validation, stable biological interfaces, dependable power, interoperable data infrastructure, scalable manufacturing and protection against algorithmic bias. Microfluidics provides the physical link between a medical device and the small quantities of biological fluid available at the point of care. Channels scaled to biological reactions shorten the distance molecules must travel to reach a sensor, reducing assay time and reagent consumption.</p>
<p>Multiple channels and sensing zones can also operate in parallel, allowing one small sample to yield a combination of measurements rather than a single biomarker value. In a programmable epidermal system described by the review, individually controlled microheaters actuate thermoresponsive hydrogel valves to route and partition sweat for time-resolved analysis. Its glucose and lactate sensors produced linear relationships between measured current and target concentration, with R² values of 0.99 in the reported tests.</p>
<p>Integrating these fluid-handling capabilities with electronics creates additional engineering demands. A functional wearable or implantable system needs sensing, power and communication components that operate while conforming to skin or tissue. Polydimethylsiloxane, commonly known as PDMS, remains prominent in research prototypes because it is optically transparent, gas-permeable and compatible with soft lithography; parylene-C is used as a barrier coating for implantable microdevices.</p>
<p>Flexible circuits, serpentine interconnects and multilayer constructions help devices tolerate stretching, bending and twisting. One three-dimensional microfluidic-electronic sweat platform supported volumetric, colorimetric and electrochemical analysis, although repeated deformation can cause layer delamination, electronic fatigue, microchannel damage or leakage. The choice of biorecognition and transduction method determines which signals a device can measure.</p>
<p>Enzyme-based electrochemical patches have monitored glucose and lactate during exercise by converting analyte oxidation into electrical current. Aptamer-based systems have targeted female hormones, including estrogen and progesterone, at low physiological concentrations. Other wearable arrays have measured sodium, potassium, glucose and lactate in sweat, while multimodal patches have combined biochemical sensing with electrocardiography and corrected for variations in sweat pH and temperature.</p>
<p>One flexible glucose biosensor reported a sensitivity of 19.97 µA mM⁻¹ cm⁻² across a physiological range of 10 µM to 0.4 mM, while its dry electrophysiological electrodes recorded signal-to-noise ratios from 23.4 to 32.8 dB. Microfluidic assays can also compress infectious-disease and wound testing into small, rapid systems. A wrist-worn chip used recombinase polymerase amplification supported by body heat to detect HIV-1 DNA within 24 minutes.</p>
<p>The reported calibration was log-linear with a value of 0.98 across 10² to 10⁵ copies per milliliter. A separate wound dressing collected exudate and measured inflammatory mediators, including tumor necrosis factor-α, interleukin-6 and interleukin-8, together with Staphylococcus aureus, temperature and pH. This platform was demonstrated in a murine wound model and assessed with exudate from a patient with a venous leg ulcer.</p>
<p>That limited clinical observation did not constitute a broad trial of safety, accuracy or treatment benefit. Digital microfluidics extends the approach by manipulating discrete droplets across electrode arrays. Individual droplets can be routed, mixed and processed in parallel without conventional micro-pumps and valves.</p>
<p>One blood-based platform integrated plasma separation, fluid transport, an in-line enzyme-linked immunosorbent assay and chemiluminescent detection. Its automated 21-step protocol quantified IgG from finger-prick blood with a reported limit of detection of 1.9 IU/mL and limit of quantification of 3.6 IU/mL, both below the review’s stated immunity threshold of 10 IU/mL. Another miniaturized device combined bacterial culture with electrochemical monitoring over a range of 2 × 10⁴ to 1.1 × 10⁹ CFU/mL, using a laser-induced graphene heater and confirming metabolic activity with microbial fuel cells.</p>
<p>These demonstrations show analytical potential, not performance across broad patient populations. Artificial intelligence adds a computational layer to interpretation of the raw signals produced by these devices. In an AI-assisted tear sensor, convolutional and recurrent neural networks corrected colorimetric readings affected by pH and color temperature.</p>
<p>The reported one-dimensional model produced an R² of 0.998 for pH, while a three-dimensional model produced an R² of 0.994 for vitamin C, calcium and protein concentrations. In another laboratory study, a deep-learning network analyzed surface-enhanced Raman scattering spectra from exosomes captured in a microfluidic chip. The system achieved a maximum capture efficiency of 85% and distinguished three non-small-cell lung-cancer cell lines from regular cell lines with a reported overall accuracy of 97.88%.</p>
<p>These results demonstrate performance in the tested laboratory settings rather than established clinical benefit. More ambitious designs connect sensing, computation and intervention. A flexible neural probe only 40 µm thick integrated optical stimulation, electrophysiological recording and chemical delivery, with a microfluidic mixer allowing two fluids to be combined at the probe tip.</p>
<p>A wearable patch used electrocardiography and heart rate to trigger a thermopneumatic micropump when heart rate exceeded 120 beats per minute during its demonstration. Another programmable platform contained 16 reservoirs with capacities from 115 to 295 µL; heating expandable microspheres squeezed drug through microchannels and microneedles, while passive mixers combined liquids from different channels. These systems illustrate possible closed loops, but they remain experimental and do not establish safe dosing or clinical effectiveness in routine care.</p>
<p>The most demanding barriers concern how the devices behave over time and how much trust patients, clinicians and regulators can place in their outputs. On skin, accumulated sweat, dermatitis, micromotion and inflammation can alter sampling conditions and signal quality. Inside the body, nonspecific protein adsorption can obstruct channels, while enzymes and antibodies may deteriorate under changing pH, temperature and mechanical shear.</p>
<p>Implanted devices can also provoke a foreign-body response, including formation of a collagen-rich capsule that separates the sensor from surrounding tissue. Antifouling hydration layers, slippery liquid-infused surfaces, rounded geometries and engineered materials have been investigated as potential countermeasures. The review emphasizes that systematic evidence on long-term stability remains limited and that standardized reference methods and calibration protocols are still needed, especially for aptamer sensors in complex fluids.</p>
<p>Scale creates further constraints. Energy harvesting from body movement, thermal gradients and biochemical reactions is promising, but the review says no approach yet supplies stable power for continuous sampling, computation and wireless communication across all real-world conditions at scale. Manufacturing must reproduce micron-scale channels, maintain sensor-to-sensor calibration consistency and control costs.</p>
<p>At the system level, continuous streams of multiple biomarkers do not fit electronic health records designed mainly for episodic clinical encounters. Secure, interoperable pipelines must compress raw readings into actionable trends without overwhelming clinicians. Regulation must also address software updates, cybersecurity, liability and algorithm safety.</p>
<p>The FDA’s Predetermined Change Control Plan offers one route for pre-specifying permitted modifications to an approved device, including algorithmic updates intended to compensate for sensor drift or physiological change. AI introduces risks that cannot be solved solely by improving the sensor. Training data may inadequately represent differences in age, sex, ethnicity, comorbidity, biofluid composition and individual physiology.</p>
<p>In low-amplitude, noisy measurements, a biased model may classify normal variation as disease or miss important signals in underrepresented groups. The review therefore calls for multicenter prospective validation, reproducible datasets, uncertainty estimates, post-hoc explanations and hardware-software safeguards that can stop autonomous systems when readings leave their validated range. Hybrid edge-cloud designs may combine privacy with rapid response, while local adaptation could compensate for sensor aging, but model changes must remain controlled and reviewable.</p>
<p>Whether the convergence of microfluidics and AI becomes routine care will ultimately depend on evidence that the complete ecosystem is safe, equitable, interoperable and reproducible beyond small prototype studies.</p>
<p><strong>Subject of Research:</strong> Translational barriers and AI challenges in microfluidics-enabled wearable and implantable medical systems for personalized medicine</p>
<p><strong>Article Title:</strong> Translational Barriers and AI‐Driven Challenges of Microfluidics‐Enabled Wearables and Implantable Systems in Personalized Medicine</p>
<p><strong>Article References:</strong> Huang, K., Fong, C. Y., Huang, X., &amp; Khoo, B. L. (2026). Translational Barriers and AI‐Driven Challenges of Microfluidics‐Enabled Wearables and Implantable Systems in Personalized Medicine. <em>Advanced Science, 13</em>(58), Article e77296. <a href="https://doi.org/10.1002/advs.77296" rel="noopener noreferrer">https://doi.org/10.1002/advs.77296</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1002/advs.77296" rel="noopener noreferrer">10.1002/advs.77296</a></p>
<p><strong>Keywords:</strong> microfluidic wearables, implantable biosensors, artificial intelligence, personalized medicine, biofluid sensing, closed-loop therapy, algorithmic bias, clinical validation, digital health, biocompatibility, Translational, Barriers</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">327258</post-id>	</item>
		<item>
		<title>Breathable fibre networks could make wearable and implantable electronics truly at home in the body</title>
		<link>https://scienmag.com/breathable-fibre-networks-could-make-wearable-and-implantable-electronics-truly-at-home-in-the-body/</link>
		
		<dc:creator><![CDATA[Denise Maddox]]></dc:creator>
		<pubDate>Tue, 06 Oct 2026 16:47:08 +0000</pubDate>
				<category><![CDATA[Medicine]]></category>
		<category><![CDATA[advancements in wearable and implantable bioelectronics]]></category>
		<category><![CDATA[biocompatibility]]></category>
		<category><![CDATA[biocompatible fibre-based electronics]]></category>
		<category><![CDATA[bioelectronics]]></category>
		<category><![CDATA[biointerface permeability in medical implants]]></category>
		<category><![CDATA[breathable fibre networks for implantable electronics]]></category>
		<category><![CDATA[closed-loop therapy]]></category>
		<category><![CDATA[digital health care]]></category>
		<category><![CDATA[e-textiles]]></category>
		<category><![CDATA[electrospinning]]></category>
		<category><![CDATA[fibre architecture]]></category>
		<category><![CDATA[Fibre-architected intelligent permeable bioelectronics]]></category>
		<category><![CDATA[foreign body response]]></category>
		<category><![CDATA[immune response to rigid vs. flexible implants]]></category>
		<category><![CDATA[implantable devices]]></category>
		<category><![CDATA[integration of electronics with living tissue]]></category>
		<category><![CDATA[liquid metal conductors]]></category>
		<category><![CDATA[mass transport in implantable electronics]]></category>
		<category><![CDATA[mechanical compliance in bioelectronic devices]]></category>
		<category><![CDATA[permeable electronics]]></category>
		<category><![CDATA[permeable implantable medical devices]]></category>
		<category><![CDATA[porous fibre networks for long-term bioelectronics]]></category>
		<category><![CDATA[soft porous fibre networks in bioengineering]]></category>
		<category><![CDATA[wearable sensors]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=241978</guid>

					<description><![CDATA[A Nature Reviews Bioengineering review outlines how soft, porous fibre networks could overcome the chronic inflammation, delamination and signal loss that plague conventional rigid bioelectronics, enabling long-term sensing and closed-loop therapies in digital health care.]]></description>
										<content:encoded><![CDATA[<p>A new review published in Nature Reviews Bioengineering argues that the next generation of medical electronics will not be built on flat, sealed chips but on soft, porous networks of fibres that let air, fluids and even cells pass straight through. The article, led by Zhizhi Wu, Yufei Zhang and Qiyao Huang of The Hong Kong Polytechnic University under the corresponding authorship of Zijian Zheng, surveys a rapidly growing field the authors call fibre-architected intelligent permeable bioelectronics, or FIPEB. Their central claim is deceptively simple: because living tissue is soft, wet and constantly remodelling itself, any electronic device that hopes to stay integrated with it for months or years must be mechanically compliant and must allow mass transport across the biointerface. Conventional rigid, impermeable devices fail on both counts, and the consequences are familiar to every clinician who has managed a failing implant.</p>
<p>The engineering logic behind permeability rests on well-established biology. When the body encounters an implanted material, the immune system mounts a foreign body response: proteins adsorb onto the surface, inflammatory cells arrive, and eventually a dense collagenous capsule walls the device off from surrounding tissue. That capsule degrades signal quality for electrodes, isolates sensors from the very biochemistry they are meant to measure, and can cause chronic irritation. Mechanical mismatch compounds the problem. Skin, muscle, brain and blood vessels deform continuously with motion, pulsation and growth, so a stiff slab of silicon or even a thin but airtight polymer film experiences shear stresses at its edges that promote delamination and tissue damage. Porous fibre networks sidestep both failure modes simultaneously, the review explains, because their open structure permits nutrient and waste exchange, supports cell proliferation at the interface in a controlled way, and distributes mechanical strain across millions of interlocking fibre contacts rather than concentrating it at a perimeter.</p>
<p>The authors organise the field around four governing parameters: permeability, conductivity, mechanical adaptability and biocompatibility. These are not independent. Increasing porosity generally improves mass transport and breathability but reduces the conductive cross-section available for electrical signals, so designers must trade one property against another. The review highlights materials strategies that break this trade-off, including liquid-metal fibre mats that remain conductive while stretching to 1,800 percent, silver-gold core-sheath nanowires that combine high conductivity with corrosion resistance, conductive hydrogels whose water-rich networks resemble soft tissue, and MXene-coated fibres that bring high capacitance to microelectrodes. Strain-insensitive conductor designs, such as buckled shells and built-in helical structures, decouple electrical resistance from mechanical deformation, allowing a fibre to stretch without its signal drifting. Zwitterionic coatings and antifouling polymers suppress nonspecific protein adsorption, while biomolecular functionalisation with fibronectin, collagen, laminin or RGD peptides can actively encourage desired cell adhesion and neurite extension.</p>
<p>Manufacturing is where fibre architecture reveals its most practical advantage, because the textile industry has spent centuries perfecting scalable ways to make, weave, knit, braid and coat fibres. The review divides fabrication into top-down and bottom-up routes. Top-down methods include in-textile photolithography, which patterns high-resolution interconnected metal circuits directly inside fabric while preserving stretchability and permeability, as well as screen printing, inkjet printing, dip coating and direct ink writing. Bottom-up approaches centre on electrospinning, which draws nanofibres from polymer solutions under high voltage and can produce mats with controlled hierarchical porosity, and on thermal drawing, coaxial spinning and wet spinning, which build multi-material fibres with core-sheath architectures. A metre-scale heterostructure printing method for high-toughness fibre electrodes, reported in 2025, exemplifies the push toward industrial throughput. The authors emphasise that combining the two families of techniques gives engineers control over structure from the nanometre to the metre, which is precisely the multiscale range over which biological tissues operate.</p>
<p>What elevates these devices from passive conductors to intelligent bioelectronics is the integration of sensing, actuation and therapy into the same fibre platform. On the sensing side, the review catalogues electrophysiological electrodes for electrocardiography, electromyography and electroencephalography, including knit band sensors that let amputees control prosthetic hands through surface EMG; biochemical sensors that track glucose in sweat through electrochemical reactions on functionalised fibres, or monitor amniotic fluid in real time during pregnancy; and biomechanical strain sensors that follow joint bending, respiration and ligament loading. Piezoelectric and triboelectric fibre systems convert body motion into electrical signals and even into power, while magnetoelastic soft fibres allow wireless readout. On the therapeutic side, fibre platforms deliver electrical stimulation, photothermal heating, optogenetic light and drugs. A bioabsorbable mechanoelectric fibre has been demonstrated as an electrical stimulation suture, and multifunctional microelectronic fibres have wirelessly modulated both gut and brain neural circuits in animal studies.</p>
<p>Perhaps the most clinically compelling vision the review describes is the closed-loop therapeutic platform, in which sensing and therapy are fused into a single feedback system. A skin-interfaced electronic wound bandage reported in 2025 combines three-dimensional sensing with targeted treatment, monitoring the wound environment and responding to it. A self-powered permeable electronic dressing manages exudate, applies electrostimulation and releases drugs for chronic wound healing. Liquid-metal stretchable bioelectronic fibres have been designed for electrical stimulation and drug delivery in minimally invasive cardiac therapy, and implantable optical fibres have delivered immunotherapeutics while simultaneously measuring tumour impedance. In such systems, the fibre network acts as both nervous system and hand of the therapist: it perceives a physiological state, computes or transmits the information, and intervenes, all while remaining permeable enough that the healing tissue grows into and around it rather than rejecting it.</p>
<p>Secondary features that sound mundane turn out to be decisive for real-world adoption. Washability, for instance, determines whether textile-based health monitors can survive the laundry, and the review notes that standardised testing protocols for wash fastness, mechanical fatigue and long-term biocompatibility are still missing but essential for regulatory translation. Optical transparency matters for devices that must not obstruct vision or clinical inspection, from gas-permeable contact lens sensors with metal-coated nanofibre meshes to transparent conductors that maintain stable conductivity under large deformation. Biodegradability opens a different design space: polycaprolactone and polylactic acid fibres can be engineered to degrade on predictable timescales, and biodegradable cotton-based piezoresistive textiles point toward devices that simply vanish when their job is done, eliminating a second surgery. The review also confronts the safety shadow hanging over fibrous biomaterials, namely the lessons of asbestos, where biopersistent fibres caused inflammation and carcinogenesis, and stresses that fibre dimensions, persistence and degradation chemistry must be controlled deliberately.</p>
<p>The translational pathway the authors sketch is candid about remaining obstacles. Long-term in vivo stability data for most fibre systems are limited compared with the decades of clinical experience behind conventional implants. Standardisation is immature: without agreed benchmarks for permeability, fatigue life, wash durability and biocompatibility, regulators and clinicians cannot compare devices on equal footing. Power and data remain bottlenecks for fully implantable systems, although fibre-shaped batteries, supercapacitors and biofuel cells, along with embroidered and liquid-metal antennas for wireless powering and communication, are closing the gap. There are also questions of scale-up economics, of sterilisation compatibility, and of the ethical dimensions of continuous physiological monitoring, from data privacy to the psychological burden of being measured around the clock. The review frames these not as reasons for scepticism but as a research agenda, arguing that the field&#8217;s rapid material progress has outpaced its testing infrastructure and that catching up is now the priority.</p>
<p>If the authors are right, the significance of fibre-architected permeable bioelectronics extends beyond any single device category. Digital health care depends on continuous, high-fidelity physiological data streams, and the quality of those streams is bounded by how well electronics can live with biology rather than merely sit on it. By making permeability a first-class design requirement alongside conductivity and compliance, the FIPEB framework reframes the biointerface as something to be engineered collaboratively with tissue rather than defended against it. The convergence of advanced soft materials, textile-scale manufacturing and closed-loop intelligence suggests a future in which a cardiac monitor is a comfortable garment, a neural interface is a thread-like probe the brain tolerates for years, and a wound dressing heals as it measures. The remaining distance between laboratory demonstrations and that future, the review concludes, will be covered not by any single breakthrough but by systematic engineering of the four properties, permeability chief among them, that let electronics and life finally share the same space.</p>
<p><strong>Subject of Research:</strong> Fibre-architected permeable bioelectronics for long-term biointegrated sensing and therapy</p>
<p><strong>Article Title:</strong> Fibre-architected intelligent permeable bioelectronics</p>
<p><strong>Article References:</strong> Wu, Z., Zhang, Y., Huang, Q., &amp; Zheng, Z. (2026). Fibre-architected intelligent permeable bioelectronics. <em>Nature Reviews Bioengineering</em>. <a href="https://doi.org/10.1038/s44222-026-00500-z" rel="noopener noreferrer">https://doi.org/10.1038/s44222-026-00500-z</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1038/s44222-026-00500-z" rel="noopener noreferrer">10.1038/s44222-026-00500-z</a></p>
<p><strong>Keywords:</strong> bioelectronics, permeable electronics, fibre architecture, wearable sensors, implantable devices, foreign body response, electrospinning, liquid metal conductors, closed-loop therapy, digital health care, biocompatibility, e-textiles</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">241978</post-id>	</item>
	</channel>
</rss>
