<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>cadaveric testing &#8211; Science</title>
	<atom:link href="https://scienmag.com/tag/cadaveric-testing/feed/" rel="self" type="application/rss+xml" />
	<link>https://scienmag.com</link>
	<description></description>
	<lastBuildDate>Sat, 03 Oct 2026 17:00:22 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://scienmag.com/wp-content/uploads/2024/07/cropped-scienmag_ico-32x32.jpg</url>
	<title>cadaveric testing &#8211; Science</title>
	<link>https://scienmag.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">73899611</site>	<item>
		<title>Which Lumbar Vertebra Breaks First in a Blast? New Study Maps Spine Fracture Risk Level by Level</title>
		<link>https://scienmag.com/which-lumbar-vertebra-breaks-first-in-a-blast-new-study-maps-spine-fracture-risk-level-by-level/</link>
		
		<dc:creator><![CDATA[Ophelia Keating]]></dc:creator>
		<pubDate>Sat, 03 Oct 2026 17:00:22 +0000</pubDate>
				<category><![CDATA[Medicine]]></category>
		<category><![CDATA[axial rigidity]]></category>
		<category><![CDATA[biomechanical analysis of lumbar fractures]]></category>
		<category><![CDATA[bone mineral density]]></category>
		<category><![CDATA[burst fractures]]></category>
		<category><![CDATA[cadaveric testing]]></category>
		<category><![CDATA[experimental and computational spine injury modeling]]></category>
		<category><![CDATA[finite element model]]></category>
		<category><![CDATA[fracture tolerance]]></category>
		<category><![CDATA[high-rate vertical loading on lumbar vertebrae]]></category>
		<category><![CDATA[impact of blast waves on lower back]]></category>
		<category><![CDATA[injury mapping of lumbar vertebrae levels]]></category>
		<category><![CDATA[injury prediction curves]]></category>
		<category><![CDATA[injury tolerance of lumbar vertebrae]]></category>
		<category><![CDATA[lumbar spine]]></category>
		<category><![CDATA[Lumbar spine fracture risk in blast injuries]]></category>
		<category><![CDATA[military biomechanics]]></category>
		<category><![CDATA[military vehicle blast trauma]]></category>
		<category><![CDATA[protective system design for soldiers]]></category>
		<category><![CDATA[spinal compression and burst fractures]]></category>
		<category><![CDATA[spinal cord injury from landmine explosions]]></category>
		<category><![CDATA[spinal posture]]></category>
		<category><![CDATA[underbelly blast]]></category>
		<category><![CDATA[vertebral geometry]]></category>
		<category><![CDATA[vertebral level-specific injury prediction]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=230994</guid>

					<description><![CDATA[A combined cadaveric and computational study has produced the first vertebra-by-vertebra fracture risk curves for the lumbar spine under blast-like vertical loading, revealing that posture, geometry, and bone density shape injury risk in strikingly level-specific ways.]]></description>
										<content:encoded><![CDATA[<p>When a landmine or improvised explosive device detonates beneath a military vehicle, the blast wave hurls the floor upward and drives a violent vertical shock through the seat, the pelvis, and ultimately the lumbar spine. The result is a distinctive and devastating injury pattern: compression and burst fractures of the lower back vertebrae, which in severe cases can crush the spinal cord and leave survivors with permanent impairment, spinal deformity, and chronic pain. Yet despite decades of research into battlefield trauma, the biomechanics community has lacked a fundamental piece of information — how fracture tolerance varies from one lumbar vertebra to the next. A new combined experimental and computational study published in the Annals of Biomedical Engineering has now delivered the first vertebral level-specific injury prediction curves for the lumbar spine under high-rate vertical loading, and the findings could reshape how protective systems for soldiers are designed.</p>
<p>The research, led by Kwong Ming Tse of Swinburne University of Technology and the University of Melbourne, together with Dale Robinson, Melanie Franklyn of Australia&#8217;s Defence Science and Technology Group, and Peter Vee Sin Lee of the University of Melbourne, tackled a problem that has long frustrated injury biomechanics researchers. Most existing spinal injury criteria were derived from tests on entire spinal columns or large spinal sections, which provide useful system-level tolerance estimates but reveal little about which individual vertebra is most likely to fail. Earlier work had hinted at the importance of this question. Studies of vertical accelerations simulating aircraft ejection showed that as acceleration increases, injuries migrate from the thoracolumbar junction down toward the lower lumbar spine. Sled experiments simulating underbelly blast found that longer-duration seat pulses of 55 milliseconds reduced spinal responses by 68 to 78 percent compared with shorter 10-millisecond pulses, producing fewer pelvic and spinal injuries. But none of these approaches could isolate the vulnerability of each lumbar level.</p>
<p>To fill this gap, the team took an unusual two-pronged approach. They obtained five cadaveric lumbar spine specimens, each free of severe abnormalities as confirmed by radiography and visual inspection, and used dual-energy X-ray absorptiometry to verify that all specimens had areal bone mineral density values within the normal range reported for young adult males aged 17 to 25 years, despite the donors being under 62 years of age. From each spine they isolated a three-vertebra segment — a central vertebra flanked by its neighbours and two intervertebral discs — with the outer vertebrae partially embedded in dental plaster potting fixtures and the middle vertebra deliberately left exposed. Each segment was then compressed at approximately one metre per second on a mechanical testing machine, a rate chosen to bridge conventional quasi-static testing and the more severe blast-level conditions, where reported vehicle floor velocities in live-fire blast events range from 2.2 to 12.8 metres per second. The researchers note that the velocity actually experienced by the lumbar spine is lower than the floor velocity because the seat, pelvis, and surrounding soft tissues attenuate the load.</p>
<p>Alongside the physical tests, the team built specimen-specific finite element models of each three-vertebra segment from high-resolution computed tomography scans with a pixel size of just 0.098 millimetres. The models were anatomically meticulous: vertebral bodies were discretised with roughly 145,000 tetrahedral elements each, cortical shells were divided into seven regions with distinct properties, intervertebral discs comprised ten annulus layers surrounding a nucleus pulposus modelled with hyperelastic material laws, and all seven major spinal ligaments were represented as membrane elements. Crucially, the CT data were used to assign bone material properties element by element, using a calibration phantom to convert Hounsfield units to bone density and a power-law regression to derive Young&#8217;s modulus for the trabecular bone. When the models were run in an explicit finite element solver replicating the compression experiments, they reproduced the measured force–displacement responses with coefficients of determination between 0.93 and 0.98, and predicted fracture loads within 10 to 34 percent of the experimental values. The models also captured the observed failure patterns, including coronal split fractures of the vertebral body, impaction fractures of the superior endplate, and isolated trabecular fractures — morphologies consistent with those reported clinically in underbelly blast casualties.</p>
<p>With the models validated, the researchers unleashed them on a series of parametric simulations that would be impossible to perform experimentally. They varied spinal posture by adding 10 degrees of flexion or extension, mimicking the range of sagittal intervertebral rotation during maximal seated trunk movement, and added 10 degrees of lateral bending comparable to voluntary side-bending. They scaled vertebral height and cross-sectional area by plus or minus 10 percent, reflecting anthropometric variation across a military population. And they swept areal bone mineral density across a physiologically relevant range of 0.8 to 1.4 grams per square centimetre, corresponding to young healthy soldiers. The results revealed a striking level-dependence that no whole-column experiment could have exposed.</p>
<p>Posture emerged as a powerful, level-specific modulator of fracture risk. At L1, L2, and L4, flexion generally reduced the likelihood of injury, shifting the fracture probability curves rightward, while extension increased the risk. At L3 the trend reversed, and at L5 both flexion and extension reduced fracture tolerance — a unique behaviour the authors attribute to the biomechanical complexity of the lowest lumbar vertebra, including its adjacency to the sacrum and its altered facet joint geometry. Lateral bending increased fracture susceptibility at the lower lumbar levels, particularly L5, where the decreased fracture load coincided with a marked increase in vertebral body loading. The stiffness analysis added another layer of nuance: at the L4–L5–S1 segment, flexion cut the compressive load at 5 millimetres of displacement from 6,545 newtons to 2,499 newtons, a 62 percent reduction. Importantly, changes in axial stiffness did not consistently translate into changes in fracture load, underscoring that stiffness and strength are distinct metrics that both matter when assessing injury tolerance.</p>
<p>Geometry and bone quality told a more consistent story. Increasing vertebral height reduced axial stiffness and fracture load at all levels except L5, where the opposite trend appeared — a finding that contrasts with earlier ex vivo work reporting a positive correlation between vertebral height and strength, and one the authors suggest may reflect biological factors such as bone mineral density and trabecular connectivity not captured in the models. Larger cross-sectional area, by contrast, consistently enhanced mechanical resistance at every level. Areal bone mineral density proved to be a strong and reliable positive predictor of compressive fracture tolerance across the entire lumbar spine, with higher density producing systematic increases in both stiffness and failure load. Yet the analysis produced a surprise: a measure called axial rigidity, derived from CT-based geometry and material properties, actually outperformed bone mineral density as a predictor of injury risk, yielding injury curves with narrow confidence intervals that converged toward a single vertebra-independent relationship.</p>
<p>The practical implications reach well beyond the laboratory. Fracture tolerance generally increased from L1 to L4, tracking the increasing size and strength of the vertebrae, but L5 consistently bucked the trend, remaining highly vulnerable despite its larger dimensions. This persistent weakness identifies the lower lumbar spine as a critical target for injury mitigation — a finding that could guide the design of vehicle seats, armour, and blast-attenuating flooring. The injury prediction curves, generated using parametric survival analysis with a Weibull distribution, also align closely with injury corridors previously developed for whole lumbar spine segments, lending credibility to the modelling approach. The authors caution that their fracture tolerance values should be read as vertebral-level injury metrics rather than direct operational thresholds, since the experiments isolated axial compression and did not replicate the full combined-loading environment of a real blast, and the experimental component involved one specimen per lumbar level owing to the scarcity of suitable cadaveric material.</p>
<p>Even with those limitations, the study marks a genuine milestone. By integrating spinal posture, vertebral geometry, and bone quality into validated, specimen-specific finite element models, the researchers have created tools for injury prediction that are both anatomically specific and clinically relevant. The framework extends naturally beyond the battlefield: the same biomechanics governs spinal loading in aviation ejections, helicopter crashes, and occupational impact scenarios. And the finding that axial rigidity may be a more robust predictor of vertebral fragility than the bone density measurements routinely used in clinics hints at a future where fracture risk assessment becomes more precise — not just for soldiers facing blast threats, but for anyone whose spine must withstand the sudden, merciless forces of a high-rate impact.</p>
<p><strong>Subject of Research:</strong> Level-specific biomechanical tolerance of lumbar vertebrae to high-rate vertical compression relevant to underbelly blast injury</p>
<p><strong>Article Title:</strong> Level-Specific Lumbar Spine Injury Tolerance Under High-Rate Vertical Loading Relevant to Underbelly Blast Environments: A Combined Cadaveric Experimental and Finite Element Study of Three-Vertebra Spinal Segments</p>
<p><strong>Article References:</strong> Tse, K. M., Robinson, D., Franklyn, M., &amp; Lee, P. V. S. (2026). Level-Specific Lumbar Spine Injury Tolerance Under High-Rate Vertical Loading Relevant to Underbelly Blast Environments: A Combined Cadaveric Experimental and Finite Element Study of Three-Vertebra Spinal Segments. <em>Annals of Biomedical Engineering</em>. <a href="https://doi.org/10.1007/s10439-026-04347-8" rel="noopener noreferrer">https://doi.org/10.1007/s10439-026-04347-8</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1007/s10439-026-04347-8" rel="noopener noreferrer">10.1007/s10439-026-04347-8</a></p>
<p><strong>Keywords:</strong> lumbar spine, underbelly blast, finite element model, cadaveric testing, fracture tolerance, bone mineral density, spinal posture, injury prediction curves, military biomechanics, burst fractures, vertebral geometry, axial rigidity</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">230994</post-id>	</item>
		<item>
		<title>Smart Biphasic Plate Shows Two Faces Under Real-World Loads, Study Finds</title>
		<link>https://scienmag.com/smart-biphasic-plate-shows-two-faces-under-real-world-loads-study-finds/</link>
		
		<dc:creator><![CDATA[Ophelia Keating]]></dc:creator>
		<pubDate>Tue, 22 Sep 2026 22:42:45 +0000</pubDate>
				<category><![CDATA[Medicine]]></category>
		<category><![CDATA[AO Fracture Monitor]]></category>
		<category><![CDATA[biomechanical analysis of biphasic femur implant]]></category>
		<category><![CDATA[biomechanical investigation of orthopedic implants]]></category>
		<category><![CDATA[biomechanics]]></category>
		<category><![CDATA[biphasic plate]]></category>
		<category><![CDATA[biphasic plate stress pattern under walking loads]]></category>
		<category><![CDATA[Bone healing]]></category>
		<category><![CDATA[cadaveric testing]]></category>
		<category><![CDATA[comparison of rigid and flexible orthopedic plates]]></category>
		<category><![CDATA[design considerations for biphasic orthopedic plates]]></category>
		<category><![CDATA[distal femur fracture]]></category>
		<category><![CDATA[distal femur fracture fixation]]></category>
		<category><![CDATA[evolution of fracture fixation techniques]]></category>
		<category><![CDATA[finite element simulation]]></category>
		<category><![CDATA[fracture fixation hardware in real-world loads]]></category>
		<category><![CDATA[gait loading]]></category>
		<category><![CDATA[human cadaver experiments for implant testing]]></category>
		<category><![CDATA[impact of multi-directional forces on orthopedic implants]]></category>
		<category><![CDATA[interfragmentary movement]]></category>
		<category><![CDATA[load measurement in orthopedic device evaluation]]></category>
		<category><![CDATA[osteosynthesis]]></category>
		<category><![CDATA[patient-specific computer simulations in orthopedic research]]></category>
		<category><![CDATA[patient-specific modeling]]></category>
		<category><![CDATA[smart implants]]></category>
		<guid isPermaLink="false">https://scienmag.com/?p=208447</guid>

					<description><![CDATA[A combined cadaveric, computational, and patient-specific study reveals that the biphasic plate's stresses shift from its central meander to its lateral edge under real gait loading.]]></description>
										<content:encoded><![CDATA[<p>A new generation of fracture-fixation hardware is teaching engineers and surgeons an uncomfortable but valuable lesson: the laboratory is not the living body. In a study published in the Annals of Biomedical Engineering, a German research team led by Annchristin Andres and Kerstin Wickert of Saarland University has carried out one of the most complete biomechanical investigations yet of the so-called biphasic plate, a distal femur implant designed to alternate between rigid and flexible behavior. By combining human cadaver experiments, patient-specific computer simulations, and real-world load measurements, the team has shown that the plate&#8217;s stress pattern changes dramatically once the messy, multi-directional forces of everyday walking replace the tidy axial pushes of a standard test rig.</p>
<p>The biphasic plate, manufactured by 41 medical in Bettlach, Switzerland, represents a deliberate departure from decades of orthopedic philosophy. Early plate fixation pursued absolute stability after anatomic reduction, exploiting direct bone healing. Later designs, such as the Limited Contact Dynamic Compression Plate introduced by Gautier and Perren, minimized soft-tissue damage, while bridging plates allowed secondary healing through callus formation. Systems like the Less Invasive Stabilization System and retrograde nailing reduced complication rates, and dual plating has shown promise in complex distal femur fractures, although a systematic review by Tripathy and colleagues found no significant functional advantage over single plating and longer procedure times. The recurring problem is that very stiff constructs, often used in osteoporotic bone to permit early weight bearing, can shield the fracture from the mechanical stimulation that callus formation requires.</p>
<p>The biphasic concept answers this dilemma by building the flexibility into the plate body itself. The implant is thicker than a conventional locking plate, raising its overall stiffness and fatigue strength, but an integrated meander-shaped recess locally reduces stiffness and permits a controlled degree of elastic movement with mechanical amplitude limitation. Previous work by Hofmann-Fliri and colleagues, who adapted the plate to the ovine tibia in an animal model, demonstrated rapid and robust callus formation and improved construct strength compared with conventional locking plates, especially at higher weight-bearing levels. Epari and colleagues, testing the plate on bone substitute material with a 20-millimeter fracture gap under axial loads from 0 to 1000 newtons, found a bilinear stiffness response that delivered more consistent interfragmentary movement and greater implant strength, properties particularly relevant for distal femur fractures.</p>
<p>What remained missing was a bridge between these controlled characterizations and the conditions an actual patient experiences. The Saarland team closed that gap with a three-part methodology. In the laboratory arm, they obtained a cadaveric femur from a 75-year-old female body donor, created a 30-degree osteotomy mimicking an OTA/AO type 33A2 distal femur fracture, and fixed it with the biphasic plate using nine head-locking screws. The specimen was clamped in a custom-designed testing rig validated in earlier work, and a spindle-driven linear actuator applied axial compression in six steps of 0.25 millimeters each at a quasi-static rate of 0.25 millimeters per second.</p>
<p>Two measurement technologies made the experiment unusually informative. A camera system documented the state of the plate&#8217;s meander structure, showing it open during the flexible phase and closed once the rigid phase engaged. Meanwhile, an implantable strain sensor known as the AO Fracture Monitor, developed by the AO Foundation in Davos, was mounted directly on the plate with two screws tightened to 1.5 newton-meters. This wireless device, originally built to track bone healing progression at 10 hertz via a strain gauge and transmit data to the cloud via Bluetooth, recorded the plate&#8217;s strain response throughout loading. At the final compression step the force reached 235 newtons, at which point the meander closed and the plate transitioned from its flexible to its rigid phase, a transition the authors note becomes apparent at roughly 200 newtons.</p>
<p>The computational arm of the study was built to reproduce exactly this experiment. The cadaveric specimen was scanned with a Siemens Somatom Definition AS64 CT scanner at 120 kVp and 0.6-millimeter slice thickness, together with a calibration phantom, and metal artifact reduction was applied to the images. After segmenting cortical and cancellous bone in consultation with treating physicians, the team generated a finite element model using ten-node tetrahedral C3D10 elements in Abaqus. Bone material properties were derived from CT gray values through density-modulus relationships, producing 25 material classes ranging from 100 to 22,000 megapascals, while the stainless steel plate and bolts were assigned a Young&#8217;s modulus of 200 gigapascals and a Poisson&#8217;s ratio of 0.3. The meander gap was modeled with frictionless tangential and hard normal contact, and six simulation steps applied the experimental forces across the proximal femur.</p>
<p>Validation proceeded on two fronts. First, the simulated relative strain change across the six loading steps closely followed the smoothed curve recorded by the AO Fracture Monitor, with only minor deviations attributed to differences in force application, clamping, bone alignment, and node selection. Second, the team replicated the benchmark scenario of Epari and colleagues, applying axial loads from 0 to 1000 newtons and confirming the characteristic nonlinear load-interfragmentary movement response. In the near cortex the load rose steadily and then steepened beyond 0.2 millimeters of interfragmentary movement; in the far cortex the pronounced load increase occurred mainly beyond 1 millimeter. The von Mises stress distribution at 1000 newtons, spanning 0 to 850 megapascals, concentrated in specific plate regions and matched the earlier study&#8217;s findings, confirming that the model captured the biphasic mechanism itself.</p>
<p>The most striking results came from the in vivo arm. Four patient-specific models were generated from clinical CT data, incorporating each patient&#8217;s anthropometry, fracture situation, plate position, screw configuration, and individualized material properties. For one patient, sensor insoles and a motion capture system were used two days after surgery to record real gait under recommended weight-bearing conditions, and a musculoskeletal simulation in AnyBody derived the hip joint reaction force over time. The other patients&#8217; loading profiles were drawn from the OrthoLoad database according to body weight and fracture side. Crucially, these load cases contained force components in all three anatomical planes, not just axial compression, and physiological proximal-distal forces during gait can reach approximately 2500 newtons, far exceeding the 1000-newton benchmark.</p>
<p>Under these realistic conditions, the stress picture inverted. Whereas axial loading distributed stresses centrally over the meander region, all four patient simulations placed maximum von Mises stresses along the lateral edge of the plate. The medial-lateral and anterior-posterior force components, together with the lever arm introduced by force transmission through the femoral head, superimpose bending and shear on axial compression, exactly as classical biomechanics described by Pauwels would predict. The authors emphasize that standardized axial test setups remain useful for implant characterization but cannot fully represent the multi-planar loading that governs implant behavior during walking, and that overly simplified in vitro or in silico setups risk missing clinically relevant stress concentrations.</p>
<p>The implications reach toward smarter, more individualized fracture care. Patient-specific simulations could identify implant regions exposed to elevated stresses during daily activities, informing future geometry optimization, working-length selection, and fixation strategies before clinical application. Combined with implantable sensors that continuously report plate strain as a surrogate for callus maturation, the approach points toward rehabilitation plans tailored to each patient&#8217;s actual loading environment. The team is candid about limitations: a single cadaver specimen, quasi-static axial loading capped at 1000 newtons, no biological or healing simulation, and possible segmentation errors mean the patient results should be read as model-based predictions rather than validated clinical outcomes. Even so, the study delivers what the authors identify as its key outcomes, validation and reproducibility, and demonstrates that only by integrating in vivo, in vitro, and in silico methods can the true mechanical life of a fracture implant be understood.</p>
<p><strong>Subject of Research:</strong> Biomechanical evaluation of the distal femur biphasic plate using in vivo, in vitro, and in silico methodologies</p>
<p><strong>Article Title:</strong> Integrated Study of the Distal Femur Biphasic Plate: Exploring In Vivo, In Vitro, and In Silico Methodologies</p>
<p><strong>Article References:</strong> Integrated Study of the Distal Femur Biphasic Plate: Exploring In Vivo, In Vitro, and In Silico Methodologies. (n.d.). <a href="https://doi.org/10.1007/s10439-026-04357-6" rel="noopener noreferrer">https://doi.org/10.1007/s10439-026-04357-6</a></p>
<p><strong>Image Credits:</strong> AI Generated</p>
<p><strong>DOI:</strong> <a href="https://doi.org/10.1007/s10439-026-04357-6" rel="noopener noreferrer">10.1007/s10439-026-04357-6</a></p>
<p><strong>Keywords:</strong> biphasic plate, distal femur fracture, finite element simulation, AO Fracture Monitor, interfragmentary movement, patient-specific modeling, bone healing, osteosynthesis, biomechanics, cadaveric testing, gait loading, smart implants</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">208447</post-id>	</item>
	</channel>
</rss>
